Fluorometer LFFM-A12 is the next generation of benchtop dual-channel Fluorometer, features 460 ± 20 nm and 525 ± 20 nm excitation filter and measures dsDNA concentration with high sensitivity lower DNA detection limit of 0.5 ng/ul. It offers blue and green channel fluorescence to measure fluorescence intensity of fluorescent reagent that combines with target molecule to read concentration of sample. Designed to accurately detect high-sensitive fluorescence while quantifying DNA, RNA, and protein.
Specifications
Dynamic range | Five orders of magnitude |
Linear dynamic range | R2 >0.995 |
Processing time | 3s (Once) |
Light source | Blue LED Green LED |
Excitation filters | 460 ± 20 nm 525 ± 20 nm |
Emission filters | 525 to 570 nm (45 nm) 575 to 640 nm (65 nm) |
Detector | Photodiode |
Repeatability | <1.5 % |
Stability | <1.5 % |
Sensitivity | ds DNA: 0.5 ng/ml |
Dimension | 194 × 155 × 72.5 mm |
Weight | 0.4 kg |
Features
Designed with 4.3 inch touch screen, small and easy to use
Easy measurement within 3 sec for DNA, RNA, and protein
High sensitivity lowest DNA detection limit is 0.5 pg/ul
Linear dynamic range with five orders of magnitude
Equipped with two fluorescence channels for nucleic acid, protein quantitation in one detection
Offers opening system
Adopts PCR tube adapter
It can save at most 1,000 data and output data by USB port
Applications
Fluorometer is used for processing scarce and difficult samples, for low quantity of DNA, RNA, or protein after extraction, also, in expensive experiments: q PCR, PCR cloning, transfection, the next generation sequencing and etc. Applied for Nucleic acid quantification, Plant GUS reporter gene detection, Apoptosis detection.
Standard Accessories
Accessories no. | Name |
---|---|
1 | Adapter for 0.5ml qPCR tube |
Optional Accessories
Accessories no. | Name |
---|---|
1 | Adapter for 0.2ml qPCR tube |
Request Quote
Dynamic range | Five orders of magnitude |
Linear dynamic range | R2 >0.995 |
Processing time | 3s (Once) |
Light source | UV LED Blue LED |
Excitation filters | 365 ± 20 nm 460 ± 20 nm |
Emission filters | 420 to 480 nm (60 nm) 525 to 570 nm (45 nm) |
Detector | Photodiode |
Repeatability | |
Stability | |
Sensitivity | ds DNA: 0.5 ng/ml |
Dimension | 194 × 155 × 72.5 mm |
Weight | 0.4 kg |
Dynamic range | Five orders of magnitude |
Linear dynamic range | R2 >0.995 |
Processing time | 3s (Once) |
Light source | Blue LED Red LED |
Excitation filters | 460 ± 20 nm 625 ± 20 nm |
Emission filters | 525 to 570 nm (45 nm) 670 to 725 nm (55 nm) |
Detector | Photodiode |
Repeatability | |
Stability | |
Sensitivity | ds DNA: 0.5 ng/ml |
Dimension | 194 × 155 × 72.5 mm |
Weight | 0.4 kg |