Need Help ?

Pharmaceutical Testing

We manufacture range of Pharmaceutical Testing equipment that is used for biomolecular interaction analysis to particle characterization and syrup filling application, etc. Choose the Pharmaceutical Testing equipment that best fits your needs.

Disintegration tester LDIT-A10
Number of basket lifting set : 1 set
Lifting frequency of the basket : 30 to 32/ min
Lifting distance of basket : 55 ± 1 mm
Minimum spacing from screen to bottom of beaker : 25 ± 2 mm
Disintegration tester LDIT-A11
Number of basket lifting set : 2 sets
Lifting frequency of the basket : 30 to 32/ min
Lifting distance of basket : 55 ± 1 mm
Minimum spacing from screen to bottom of beaker : 25 ± 2 mm
Disintegration tester LDIT-A12
Number of basket lifting set : 3 sets
Lifting frequency of the basket : 30 to 32/ min
Lifting distance of basket : 55 ± 1 mm
Minimum spacing from screen to bottom of beaker : 25 ± 2 mm
Dissolution tester LDLT-A10
No of vessels : 1
No of poles : 1
Position of vessels and poles : One vessel and one pole arranged on one line
Head part movement : Manually turn over
Dissolution tester LDLT-A11
No of vessels : 3
No of poles : 3
Position of vessels and poles : Three vessel and three pole arranged on one line
Head part movement : Manually turn over
Dissolution tester LDLT-A12
No of vessels : 6
No of poles : 6
Position of vessels and poles : Six vessel and six pole arranged on one line
Head part movement : Manually turn over
Dissolution tester LDLT-A13
No of vessels : 6
No of poles : 6
Position of vessels and poles : Six vessel and six pole arranged on one line
Head part movement : Electrically turn over
Dissolution tester LDLT-A14
No of vessels : 8
No of poles : 6
Position of vessels and poles : Six vessels and six poles in front and other two vessels at back
Head part movement : Manually turn over
Dissolution tester LDLT-A15
No of vessels : 8
No of poles : 6
Position of vessels and poles : Six vessels and six poles in front and other two vessels at back
Head part movement : Electrically turn over
Dissolution tester LDLT-A16
No of vessels : 8
No of poles : 8
Position of vessels and poles : Four vessels and four poles in front and others at back
Head part movement : Electrically turn over
Dissolution tester LDLT-A17
No of vessels : 12
No of poles : 12
Position of vessels and poles : Six vessels and six poles in front and other six poles and vessels at back
Head part movement : Electrically (automatic) turn over
Friability Tester LTFT-A10
Number of cylinder : 2
Rotating speed of cylinders : 25 rpm
Rotating accuracy : ± 1 rpm
Counting mode : Adopted with countdown, 100 turns can be set arbitrarily
Friability Tester LTFT-A11
Number of cylinder : 2
Rotating speed of cylinders : 20 to 100 rpm can be set arbitrarily
Rotating accuracy : ± 1 rpm
Counting mode : Adopted with countdown, 5 to 900 turns can be set arbitrarily
Friability Tester LTFT-A12
Number of cylinder : 2
Rotating speed of cylinders : 25 rpm can be set arbitrarily
Rotating accuracy : ± 1 rpm
Counting mode : Adopted with countdown, 5 to 900 turns can be set arbitrarily
Friability Tester LTFT-A13
Number of cylinder : 1
Rotating speed of cylinders : 25 rpm
Rotating accuracy : ± 1 rpm
Counting mode : 10 to 900 turns can be set arbitrarily
Powder Flowability Tester LPFL-A10
Disc : Diameter 100 mm
Funnel Outer Diameter : Outer diameter 155 mm
Funnel Inner Diameter : 145 mm
Test Sample : Surfactant Powder and Particles, non-agglomerated powder
Single Punch Tablet Press Machine LSTP-A10
Maximum pressure : 60 KN
Maximum diameter Tablet : 25 mm
Maximum depth of filling : 16 mm
Maximum thickness of tablet : 10 mm
Single Punch Tablet Press Machine LSTP-A11
Maximum pressure : 50 KN
Maximum diameter Tablet : 20 mm
Maximum depth of filling : 12 mm
Maximum thickness of tablet : 6 mm
Single Punch Tablet Press Machine LSTP-A12
Maximum pressure : 15 KN
Maximum diameter Tablet : 12 mm
Maximum depth of filling : 11 mm
Maximum thickness of tablet : 6 mm
Syrup Filling Machine LSFM-A10
Material Stainless : 316 L Stainless Steel
Automatic Grade : Semi-Automatic
Power Source : Pneumatic
Filling Head : Single Head or Double Head or Customized
Tablet Counting Machine LTCM-A10
Diameter of counting plate : 400 mm
Hole No. of counting slide/range : 5 to 100 (optional)
Production efficiency : 10 to 20 vials/ min
Rate of Bottles : 36 bottles/ minute
Tablet Hardness tester LTHT-A10
Hardness measurement range : 2 to 196 N, 0.2 to 20 kg
Tablet diameter : 2 to 20 mm
No. of testing tablets in each group : ≤ 100 tablets
Built in printer : No
Tablet Hardness tester LTHT-A11
Hardness measurement range : 2 to 200 N, 0.2 to 20 kg
Tablet diameter : 2 to 40 mm
No. of testing tablets in each group : ≤ 100 tablets
Built in printer : No
Tablet Hardness tester LTHT-A12
Hardness measurement range : 2 to 200 N, 0.2 to 20 kg
Tablet diameter : 2 to 40 mm
No. of testing tablets in each group : ≤ 100 tablets
Built in printer : Yes
Tap Density Tester LTDT-A10
Work Station : 1
Sample Volume : ≤ 250 ml
Sample Weight : ≤ 500 g
Number of Tapping : 0 to 99999 (set 0 to output bulk density)
Tap Density Tester LTDT-A11
Work Station : 2
Sample Volume : ≤ 250 ml
Sample Weight : ≤ 500 g
Number of Tapping : 0 to 99999 (set 0 to output bulk density)
Tap Density Tester LTDT-A12
Work Station : 3
Sample Volume : ≤ 100 ml
Sample Weight : ≤ 500 g
Number of Tapping : 0 to 99999 (set 0 to output bulk density)