Testing Instruments

We manufacture different types of testing equipment ranging from NDT testing instruments paper testing instruments, plastic testing instruments, rubber testing instruments, soil testing instruments, etc. that are widely used by laboratories depending upon their needs.

Aging Oven TAO-A10
The maximum temperature : 300°C
Temperature fluctuation : Within ± 0.5°C
Temperature uniformity : Within ± 1°C
Rotate speed of the turntable : 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Automatic horizontal tensile tester TP-B11
Sample (size) length : 90 to 200 mm
Sample width : 15 mm, 25 mm, 50mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
Accuracy : ± 1 %
Automatic horizontal tensile tester TP-B12
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy : ± 1 %
Bekk Smoothness tester TP-L20
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
Contact pressure : 100 ± 2 kPa
Benchtop gloss meter TBGM-A10
Test angle : 60°
Gloss aperture : 2 × 3 mm
Measurement range : 0 to 1000 GU
Repeatability : 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Carton compression tester TP-I10
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Operating stroke : 500 mm (customized)
Carton compression tester TP-I11
Measuring range : 1 to 50 kN
Indication error : < ± 1%
Platen Size : 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke : 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Charpy/ Izod Impact Tester TCI-A10
Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy : 0.001 J
Pendulum up angle : 160°
COBB sample cutter TP-C30
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Dimension : 240×288×435 mm
Coefficient of friction tester TP-D10
Measurement range : 0.01 to 10 N
Slider weight : 200 g
Slider size : 63×63 mm
Testing accuracy : ± 2 %
Crush tester TP-L10
Measurement range : 5 to 500 N, 50 to 3000 N
Resolution : 1 N
Accuracy : ± 1 %
Variability : ≤ 1 %
Digital Brinell hardness Tester TDBH-A10
Test force : 612.5 N, 980 N, 1225 N
Brinell hardness test : 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness measuring area : 8 to 650 HBW (hard metals steel ball)
Hardness indication : Digital display
Digital low load Vickers Hardness tester TDVH-A10
Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
Error range in display : ± 3.0 %, ± 2.0 %
Hardness indication : Digital display
DIN abrasion tester TDAT-A10
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
Abrasion stroke : 40 ± 0.2 M
Electronic bending stiffness tester TP-E10
Testing speed : 200° ± 20° / min
Test range : 1 to 10000 mN
Indicating Error : ± 1 %
Testing length : 5, 10, 15, 20, 25, 50 mm
Electronic Tearing tester TP-J21
Capacity : 10 -16000 mN
Resolution : 0.1 mN
Tearing arm : 104 ± 1 mm
Tearing angle : 27.5° ± 5°
Falling Weight Impact Tester TFWT-A10
Temperature range : 10 to 35°C
Maximum falling height : 2000 mm
Resolution of displacement : 1 mm
Height error : < ± 2 mm
Folding endurance tester TP-M10
Measuring scope : 0 to 99999 s
Folding angle : 135° ± 2°
Tensile scope : 4.9 to 14.7 N
Folding head suture size : 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Heat sealer THS-A10
Seal temperature : Room temperature -250°C
Control accuracy : ± 0.2°C
Dwell time : 0.1 S to 999.9 S
Dwell pressure : 0.05 to 0.7 MPa
Ink rubber tester TP-F10
Sample size (L*B) : 230×50 mm (can join short samples together)
Rub pressure : 20 ± 0.2 N
Friction speed : 43 times / min
Friction area (L*B) : 155×50 mm
Internal Ply bond Tester TP-J11
Capacity : A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle : 90°
Unit : Lb-ft/in2  J/m2
Error : A: ± 1 J/m2 B: ± 2 J/m2
Lasting adhesive tester TLAT-A10
Standard roller : 2000 ± 50 g
Testing stations : 3
Dimension (L*W*H) tester : 320×210×550 mm (3 stations)
Weight for stations : 10 kg (3 stations)
Lasting adhesive tester TLAT-A11
Standard roller : 2000 ± 50 g
Testing stations : 6
Dimension (L*W*H) tester : 650×210×550 mm (6 stations)
Weight for stations : 15 kg (6 stations)
Melt flow Indexer TMFI-A10
Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate : 0.001 S
Temperature range : 50 to 400°C
Temperature precision : ± 0.5°C
Melt flow Indexer TMFI-A11
Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate : 0.001 S
Temperature range : 50 to 400°C
Temperature precision : ± 0.5°C
Mooney viscometer TMV-A10
Control temperature range : Normal temperature to 200°C
Temperature display resolution : 0.01°C
Temperature control accuracy : ± 0.3°
Calibration accuracy : Mooney value ± 0.5
Mullen burst tester TP-K10
Measurement range : 0 to 5600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 170 ± 15 ml/min
Clamp pressure : ≥ 690 kPa
Mullen burst tester TP-K11
Measurement range : 0 to 1600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 95 ± 5 ml/min
Clamp pressure : ≥ 430 kPa
No rotor rheometer TNRR-A10
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
Rotor speed : 100 times/ min
Oxygen Index Tester TOIT-A10
Resolution : 0.1 % O2
Measuring range : 0 to 100 % O2
Precision : ± 0.4 % O2
Response time : < 10 S
Paper air permeability tester TP-J10
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Inner diameter of grip ring : 35.68 ± 0.05 mm
Paper and cardboard thickness meter TP-E20
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Contact pressure (to create false weight) : 100 ± 10 kPa
Paper and cardboard thickness meter TP-E21
Measuring range : 0 to 20 mm
Accuracy : 0.01 mm
Gauge : Analogue gauge display
Contact pressure (to create false weight) : 20 ± 0.5 kPa
Paper tearing tester TP-J20
Measuring range : 0 to 1000 mN
Resolution : 0.1 mN
Indication error : ± 1 %
Tearing arm : 104 ± 1 mm
Portable Vibration Calibrator LPVC-A10
Frequency (continually adjustable) : 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) : 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) : 40 Hz to 320 Hz + 0.5dB +1 digit
Amplitude displacement ( at 50 μm pk-pk ) : 40 Hz to 320 Hz + 0.5 dB + 1 digit
Primary adhesive tester TPAT-A10
Inclined adjustable angle : 0 to 40°
Panel width : 120 mm
Test area width : 80 mm
Standard steel balls : 1/32 to 1 inch
Pulp beating (refining) freeness tester TP-C10
Measurement range : 0 to 100° SR
Sealed testing speed : 100 ± 10 mm/s
Volume of distilled water : 1000 ± 5 ml
Draining time : 149 ± 1 s
Puncture strength tester TP-J12
Measuring range : A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance : <0.25 J
Pyramid dimension : Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension : 800×470×840 mm
Rockwell hardness meter (motorized type) TRHM-B10
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Brinell hardness test : 306, 613, 1839 N
Vickers hardness test : 294, 588, 980 N
Rockwell hardness meter TRHM-A10
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 0 to 30 S
Hardness indication : Analogue display
Rockwell hardness meter TRHM-A11
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 1 to 30 S
Hardness indication : Digital display
Rubber low temperature brittleness tester TRBT-A10
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Temperature fluctuation : <± 0.5°C
Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy : ± 0.3 ℃
Impact speed : 0℃ to -30℃ around 2.5 ℃/min
-30℃ to -40℃ around 2.5 ℃/min
-40℃ to -70℃ around 2.0 ℃/min
Max dimension L × W × H : 910 × 510 × 860 mm
Rubber-weiss plasticity testing machine TRWM-A10
Temperature range : RT 50° to 300°
Temperature accuracy : ± 1°
Measuring range : 0.01 to 25 mm
Accuracy : ± 0.01 mm
Softness tester TP-H10
Measuring range : 10 to 1000 mN
Division value : 1 mN
Accuracy : ± 1%
Indicating Error : ≤ 0.5
Soil moisture meter TSMM-A10
Measurement range : 0 to 80 %
Resolution : 0.1
Accuracy : ± 2 % n (non-saturation condition)
Needle : 280 mm
Soil moisture meter TSMM-A11
Measurement range : 0 to 90 %
Resolution : 0.1 or 0.01
Accuracy : ± 5 % n (non-saturation condition)
Needle : 235 mm
Soil moisture meter TSMM-A12
Measurement range : 0 to 60 %
Resolution : 0.1
Accuracy : ± 5 % n (non-saturation condition)
Needle : 280 mm
Soil nutrient tester TSNA-A10
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Repeatability error : A (absorbency of light) <0.005
Soil nutrient tester TSNA-A11
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Repeatability error : A (absorbency of light) <0.005
Soil Salinity tester TSST-A10
Salinity Measurement range : 0.00 to 19.99 ms/cm
Measuring accuracy : EC ± 2% full scale
Temperature Measurement range : -5 to 50°C
Temperature accuracy : ± 0.5°C
Soil water hardness meter TSHM-A10
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measuring depth : 0 to 40 mm
Soil water hardness meter TSHM-A11
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measuring depth : 0 to 450 mm
Soil Water potential tester TSWT-A10
Measuring range : 0 to 100 kPa
Resolution : 0.01 kPa
Accuracy : ± 1 kPa
Soil temperature measuring range : -55 to 105°C
Standard strip cutter TP-G10
Sample width : 15 mm
Sample maximum length : 300 mm
Parallelism : ≤ 0.1 mm
Dimension : 240×520×70 mm
Tensile Stiffness Tester TP-B10
Sample (size) length : 38×70 mm
Measuring range : (1-500) mN.m (divided into 7 small ranges)
Indication error : 0.02
Test speed : (200° ± 20°)/ min
Three roll mill machine TRMM-A10
Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range : RT to 300°C
Temperature control system : PID control
Display : LED display
Vacuum Leak Tester TVLT-A10
Vacuum degree : 0 to 90 KPa
Accuracy : 1 % FS
Resolution : 0.1 KPa
Vacuum chamber effective size : 270 × 210 mm
Vertical tensile tester TP-B20
Sample (size) length : 0 to 200 mm adjustable
Sample width : 15 mm
Measuring range : 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy : ± 1 %
Vicat softening temperature & HDT machine TVHT-A10
Operating temperature : Ambient temperature to 300°C
Heating rate : 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
Maximum temp. error with heating speed : ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Range of deformation : 0 to 10 mm
Water absorption tester TP-C20
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Number of specimen holders : 5
Water absorption tester- Cobb Tester TP-C21
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Metal roller weight : (10 ± 0.5) kg
Whiteness and chromaticity tester TP-A10
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability : ≤ 0.1 within 30 min
Accuracy : Chromaticity co-ordinate 0.0001
Whiteness meter TP-A11
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Zero drift : ≤ 0.1 %