We manufacture different types of testing equipment ranging from NDT testing instruments paper testing instruments, plastic testing instruments, rubber testing instruments, soil testing instruments, etc. that are widely used by laboratories depending upon their needs.
The maximum temperature : | 300°C |
Temperature fluctuation : | Within ± 0.5°C |
Temperature uniformity : | Within ± 1°C |
Rotate speed of the turntable : | 11 r/min to 12r/min, turntable dimension diameter: 285 mm |
Sample (size) length : | 90 to 200 mm |
Sample width : | 15 mm, 25 mm, 50mm |
Measuring range : | 0 to 30, 0 to 100 N,0 to 300 N |
Accuracy : | ± 1 % |
Sample (size) length : | 180 mm (180, 150, 100, 90, 50 mm adjustable) |
Sample width : | 15 mm |
Measuring range : | 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N |
Accuracy : | ± 1 % |
Measuring scope : | ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s) |
Accuracy : | ±0.1 s within 300 s |
Vacuum system volume (ml) : | Bigger volume: 380 ± 1 Smaller volume: 38 ± 1 |
Contact pressure : | 100 ± 2 kPa |
Test angle : | 60° |
Gloss aperture : | 2 × 3 mm |
Measurement range : | 0 to 1000 GU |
Repeatability : | 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU) |
Measuring range : | 0.1 to 10 kN |
Indication error : | < ± 1% |
Platen Size : | 500×500 mm (customized) |
Operating stroke : | 500 mm (customized) |
Measuring range : | 1 to 50 kN |
Indication error : | < ± 1% |
Platen Size : | 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized) |
Operating stroke : | 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized) |
Impact Speed & Energy (charpy) : | 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J |
Impact energy (Izod) : | 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J |
Resolution of impact energy : | 0.001 J |
Pendulum up angle : | 160° |
Sample diameter : | 125 mm |
Sample error : | ± 0.2 mm |
Sample Thickness : | 0.1 to 1.0 mm |
Dimension : | 240×288×435 mm |
Measurement range : | 0.01 to 10 N |
Slider weight : | 200 g |
Slider size : | 63×63 mm |
Testing accuracy : | ± 2 % |
Measurement range : | 5 to 500 N, 50 to 3000 N |
Resolution : | 1 N |
Accuracy : | ± 1 % |
Variability : | ≤ 1 % |
Test force : | 612.5 N, 980 N, 1225 N |
Brinell hardness test : | 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N |
Hardness measuring area : | 8 to 650 HBW (hard metals steel ball) |
Hardness indication : | Digital display |
Test force : | 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N |
Hardness value symbol : | HV1, HV5, HV10, HV20, HV30, HV250 |
Error range in display : | ± 3.0 %, ± 2.0 % |
Hardness indication : | Digital display |
Test arm weight : | 2.5 N |
Additional Loads : | 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N, |
Idler : | 150 mm |
Abrasion stroke : | 40 ± 0.2 M |
Testing speed : | 200° ± 20° / min |
Test range : | 1 to 10000 mN |
Indicating Error : | ± 1 % |
Testing length : | 5, 10, 15, 20, 25, 50 mm |
Capacity : | 10 -16000 mN |
Resolution : | 0.1 mN |
Tearing arm : | 104 ± 1 mm |
Tearing angle : | 27.5° ± 5° |
Temperature range : | 10 to 35°C |
Maximum falling height : | 2000 mm |
Resolution of displacement : | 1 mm |
Height error : | < ± 2 mm |
Measuring scope : | 0 to 99999 s |
Folding angle : | 135° ± 2° |
Tensile scope : | 4.9 to 14.7 N |
Folding head suture size : | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm |
Seal temperature : | Room temperature -250°C |
Control accuracy : | ± 0.2°C |
Dwell time : | 0.1 S to 999.9 S |
Dwell pressure : | 0.05 to 0.7 MPa |
Sample size (L*B) : | 230×50 mm (can join short samples together) |
Rub pressure : | 20 ± 0.2 N |
Friction speed : | 43 times / min |
Friction area (L*B) : | 155×50 mm |
Capacity : | A: 20 to 500 J/m2 B: 500 to 1000 J/m2 |
Impact angle : | 90° |
Unit : | Lb-ft/in2 J/m2 |
Error : | A: ± 1 J/m2 B: ± 2 J/m2 |
Standard roller : | 2000 ± 50 g |
Testing stations : | 3 |
Dimension (L*W*H) tester : | 320×210×550 mm (3 stations) |
Weight for stations : | 10 kg (3 stations) |
Standard roller : | 2000 ± 50 g |
Testing stations : | 6 |
Dimension (L*W*H) tester : | 650×210×550 mm (6 stations) |
Weight for stations : | 15 kg (6 stations) |
Measuring range : | 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density) |
Measuring rate : | 0.001 S |
Temperature range : | 50 to 400°C |
Temperature precision : | ± 0.5°C |
Measuring range : | 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density) |
Measuring rate : | 0.001 S |
Temperature range : | 50 to 400°C |
Temperature precision : | ± 0.5°C |
Control temperature range : | Normal temperature to 200°C |
Temperature display resolution : | 0.01°C |
Temperature control accuracy : | ± 0.3° |
Calibration accuracy : | Mooney value ± 0.5 |
Measurement range : | 0 to 5600 kPa |
Accuracy : | ± 0.5 % F.S. |
Compression speed : | 170 ± 15 ml/min |
Clamp pressure : | ≥ 690 kPa |
Measurement range : | 0 to 1600 kPa |
Accuracy : | ± 0.5 % F.S. |
Compression speed : | 95 ± 5 ml/min |
Clamp pressure : | ≥ 430 kPa |
Temperature tester : | Room temperature to 200°C |
Temperature display resolution : | 0.1°C |
Temperature control accuracy : | ≤ ± 0.3°C |
Rotor speed : | 100 times/ min |
Resolution : | 0.1 % O2 |
Measuring range : | 0 to 100 % O2 |
Precision : | ± 0.4 % O2 |
Response time : | < 10 S |
Measuring range : | 0 to 1000 ml/min |
Test area : | 10 ± 0.02 cm2 |
Area differential pressure : | 1 ± 0.01 kPa |
Inner diameter of grip ring : | 35.68 ± 0.05 mm |
Measuring range : | 0 to 4 mm |
Accuracy : | 0.01 or 0.001 mm |
Gauge : | Analogue gauge display |
Contact pressure (to create false weight) : | 100 ± 10 kPa |
Measuring range : | 0 to 20 mm |
Accuracy : | 0.01 mm |
Gauge : | Analogue gauge display |
Contact pressure (to create false weight) : | 20 ± 0.5 kPa |
Measuring range : | 0 to 1000 mN |
Resolution : | 0.1 mN |
Indication error : | ± 1 % |
Tearing arm : | 104 ± 1 mm |
Frequency (continually adjustable) : | 10 Hz to1280 Hz + 0.01 % |
Amplitude acceleration ( at 30m/s2 pk ) : | 40 Hz to 320 Hz + 0.3 dB + 1 digit |
Amplitude velocity ( at 25mm / sec pk ) : | 40 Hz to 320 Hz + 0.5dB +1 digit |
Amplitude displacement ( at 50 μm pk-pk ) : | 40 Hz to 320 Hz + 0.5 dB + 1 digit |
Inclined adjustable angle : | 0 to 40° |
Panel width : | 120 mm |
Test area width : | 80 mm |
Standard steel balls : | 1/32 to 1 inch |
Measurement range : | 0 to 100° SR |
Sealed testing speed : | 100 ± 10 mm/s |
Volume of distilled water : | 1000 ± 5 ml |
Draining time : | 149 ± 1 s |
Measuring range : | A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 % |
Frictional resistance : | <0.25 J |
Pyramid dimension : | Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm |
Dimension : | 800×470×840 mm |
Preliminary test force : | 98 N |
Total test force : | 588, 980, 1471 N |
Brinell hardness test : | 306, 613, 1839 N |
Vickers hardness test : | 294, 588, 980 N |
Preliminary test force : | 98 N |
Total test force : | 588, 980, 1471 N |
Total test force dwell time : | 0 to 30 S |
Hardness indication : | Analogue display |
Preliminary test force : | 98 N |
Total test force : | 588, 980, 1471 N |
Total test force dwell time : | 1 to 30 S |
Hardness indication : | Digital display |
Temperature range : | -60°C to 0°C |
Temperature accuracy : | ± 0.5°C |
Impact speed : | 2 m/s ± 0.2 m/s |
Temperature fluctuation : | <± 0.5°C |
Temperature control range : | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy : | ± 0.3 ℃ |
Impact speed : | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Max dimension L × W × H : | 910 × 510 × 860 mm |
Temperature range : | RT 50° to 300° |
Temperature accuracy : | ± 1° |
Measuring range : | 0.01 to 25 mm |
Accuracy : | ± 0.01 mm |
Measuring range : | 10 to 1000 mN |
Division value : | 1 mN |
Accuracy : | ± 1% |
Indicating Error : | ≤ 0.5 |
Measurement range : | 0 to 80 % |
Resolution : | 0.1 |
Accuracy : | ± 2 % n (non-saturation condition) |
Needle : | 280 mm |
Measurement range : | 0 to 90 % |
Resolution : | 0.1 or 0.01 |
Accuracy : | ± 5 % n (non-saturation condition) |
Needle : | 235 mm |
Measurement range : | 0 to 60 % |
Resolution : | 0.1 |
Accuracy : | ± 5 % n (non-saturation condition) |
Needle : | 280 mm |
Measuring range : | 0.001 to 9999 |
Stability : | A (absorbency of light) <0.003 within 3 mins |
Linearity error : | <3.0 % |
Repeatability error : | A (absorbency of light) <0.005 |
Measuring range : | 0.001 to 9999 |
Stability : | A (absorbency of light) <0.003 within 3 mins |
Linearity error : | <3.0 % |
Repeatability error : | A (absorbency of light) <0.005 |
Salinity Measurement range : | 0.00 to 19.99 ms/cm |
Measuring accuracy : | EC ± 2% full scale |
Temperature Measurement range : | -5 to 50°C |
Temperature accuracy : | ± 0.5°C |
Maximum load : | 100 kg ( kg and N can be switched automatically) |
Resolution : | 0.01 g |
Accuracy : | ± 0.5 % |
Measuring depth : | 0 to 40 mm |
Maximum load : | 100 kg ( kg and N can be switched automatically) |
Resolution : | 0.01 g |
Accuracy : | ± 0.5 % |
Measuring depth : | 0 to 450 mm |
Measuring range : | 0 to 100 kPa |
Resolution : | 0.01 kPa |
Accuracy : | ± 1 kPa |
Soil temperature measuring range : | -55 to 105°C |
Sample width : | 15 mm |
Sample maximum length : | 300 mm |
Parallelism : | ≤ 0.1 mm |
Dimension : | 240×520×70 mm |
Sample (size) length : | 38×70 mm |
Measuring range : | (1-500) mN.m (divided into 7 small ranges) |
Indication error : | 0.02 |
Test speed : | (200° ± 20°)/ min |
Mixed capacity : | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range : | RT to 300°C |
Temperature control system : | PID control |
Display : | LED display |
Vacuum degree : | 0 to 90 KPa |
Accuracy : | 1 % FS |
Resolution : | 0.1 KPa |
Vacuum chamber effective size : | 270 × 210 mm |
Sample (size) length : | 0 to 200 mm adjustable |
Sample width : | 15 mm |
Measuring range : | 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N |
Accuracy : | ± 1 % |
Operating temperature : | Ambient temperature to 300°C |
Heating rate : | 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min) |
Maximum temp. error with heating speed : | ± 5°C under 50°C/ h, ± 1°C under 120°C/ h |
Range of deformation : | 0 to 10 mm |
Measurement range : | 0 to 200 mm |
Specimen size : | 15×250 mm |
Division value : | 1 mm |
Number of specimen holders : | 5 |
Metal Cylinder inner area : | (100 ± 0.2) cm2 |
Metal Cylinder height : | 50 mm |
Metal roller width : | (200 ± 0..5) mm |
Metal roller weight : | (10 ± 0.5) kg |
Sample (size) length : | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode : | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability : | ≤ 0.1 within 30 min |
Accuracy : | Chromaticity co-ordinate 0.0001 |
Sample (size) length : | Diameter ≥30 mm, Thickness ≤ 40 mm |
System : | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source : | D65 as illuminating source |
Zero drift : | ≤ 0.1 % |