Need Help ?

Airborne Particle Counter

We manufacture Airborne Particle Counters ranging from dual flow particle counter, dust monitor, handheld airborne particle counter, portable airborne particle counter which are used by laboratories for clean room monitoring, indoor air quality testing etc. One can use it on a regular basis to ensure that the cleanroom is still operational between validations.

Dual Flow Particle Counter LDPC-A10
Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
Flow rates : 2.83 L/min
50 mL/min
Sensitivity : 0.3 µm
Test class : Class 100 ∼ Class 300,000
Dust Monitor LDMR-A10
Particulate matter concentration : PM10, PM2.5, PM1.0, TSP
Particulate channels and size : 15 channels, 0.3 to 25 µm
Sensitivity : 0.0001 mg/m3
Measuring Range : 0.01 to 20 mg/m3
Handheld Airborne Particle Counter LHPC-A11
Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
Flow rate : 0.1 CFM ( 2.83 L/min )
Test class : Class 100 ∼ Class 300,000
Test period : 1 min ∼ 15 min ( 15 levels )
Handheld Dust Meter LDMH-A10
Measurement range : PM 1.0, PM 2.5, and PM 10.0
Resolution : 0.1 µg/m3
Concentration limits : 1000 µg/m3
Accuracy : 0.1
Portable Airborne Particle Counter LPPC-A10
Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate : 0.1 CFM ( 2.83 L/min )
Test class : Class 100 ∼ Class 300,000
Built-in battery : No
Portable Airborne Particle Counter LPPC-A11
Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate : 0.1 CFM ( 2.83 L/min )
Test class : Class 100 ∼ Class 300,000
Built-in battery : Yes
Portable Airborne Particle Counter LPPC-A20
Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate : 1 CFM ( 28.3 L/min )
Test class : Class 100 ∼ Class 300,000
Test period : 1 min ∼ 10 min
Portable Airborne Particle Counter LPPC-A21
Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
Flow Rate : 0.1 CFM ( 2.83 L/min )
Test class : Class 100 ∼ Class 300,000
Test period : 1 min ∼ 10 min
Portable Airborne Particle Counter LPPC-A30
Size channel : 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)
Flow rate : 28.3 L/min
Teat way : UCL
Test period : 1 to 40 minute
Portable Airborne Particle Counter LPPC-B10
Particle size channels : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate : 1.0 CFM ( 28.3 L/min )
Sensitivity : 0.3 µm
Test period : 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )
Portable Airborne Particle Counter LPPC-B11
Particle size channels : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate : 50 L/min
Sensitivity : 0.3 µm
Test period : 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )
Portable Airborne Particle Counter LPPC-B12
Particle size channels : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate : 100 L/min
Sensitivity : 0.3 µm
Test period : 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )