Ask An Expert
Pipette Controller PPC100L is a compatible and ergonomically designed single-handed operation unit, used with plastic and glass pipettes from 0.1 to 100mL. Features easy and adjustable speed control with motor/gravity dispensing speed and aspiration speed of 25 ml < 7s. Light-weight design with 0.45μm replaceable hydrophobic filter and lithium-ion battery, offers >8 hrs of intermittence usage with 2 to 3 hrs of charging time.
Pipette controller is used to quickly fill and release accurate volume of liquids for liquid transferring and measurement across various fields such as molecular biology, microbiology, immunology, cell culture, analytical chemistry, biochemistry, biotechnology, genetics, in diagnostic test, molecular screening, kinetic studies and DNA amplification etc.
| Aspiration speed | 25 ml < 5s |
| Dispensing speed | Motor/gravity |
| Aspiration/Dispensing speed | 8 shifts |
| Pipette type | Plastic and glass pipettes, Pasteur pipette |
We offer a comprehensive collection of micropipettes with levels of accuracy and precision designed for better and quick one handed operation, these are used to dispense measured volume of liquids with a rapid release valve for quick and easy dispensing. These are autoclavable and light to use with disposable pipette tips.
| Test Volume | 5 μL |
| Accuracy error | 1.3 % |
| Precision error | 1.2 % |
| Test Volume | 10 μL |
| Accuracy error | 0.8 % |
| Precision error | 0.8 % |
| Test Volume | 20 μL |
| Accuracy error | 0.6 % |
| Precision error | 0.5 % |
| Test Volume | 25 μL |
| Accuracy error | 0.5 % |
| Precision error | 0.3 % |
| Test Volume | 50 μL |
| Accuracy error | 0.5 % |
| Precision error | 0.3 % |
| Test Volume | 100 μL |
| Accuracy error | 0.5 % |
| Precision error | 0.3 % |
| Test Volume | 200 μL |
| Accuracy error | 0.4 % |
| Precision error | 0.2 % |
| Test Volume | 250 μL |
| Accuracy error | 0.4 % |
| Precision error | 0.2 % |
| Test Volume | 500 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.2 % |
| Test Volume | 1000 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.2 % |
| Test Volume | 2000 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.15 % |
| Test Volume | 5000 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.15 % |
| Volume Range | 0.5 – 10 μL |
| Increment | 0.01 μL |
| Test Volume | 10 μL 1 μL |
| Accuracy Error | ±1.00 % ±3.50 % |
| Volume Range | 5 – 50 μL |
| Increment | 0.1 μL |
| Test Volume | 50 μL 5 μL |
| Accuracy Error | ±0.80 % ±3.00 % |
| Volume Range | 30 – 300 μL |
| Increment | 1 μL |
| Test Volume | 300 μL 30 μL |
| Accuracy Error | ±0.60 % ±3.00 % |
| Volume Range | 100 - 1000 μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 100 μL |
| Accuracy Error | ±0.60 % ±3.00 % |
| Volume Range | 0.1 - 2.5 μL |
| Increment | 0.05 μL |
| Test Volume | 2.5 μL 1.25 μL 0.25 μL |
| Accuracy error | 2.50 % 3.00 % 12.00 % |
| Volume Range | 0.5 - 10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| Accuracy error | 1.00 % 1.50 % 2.50 % |
| Volume Range | 2 - 20 μL |
| Increment | 0.5 μL |
| Test Volume | 20 μL 10 μL 2 μL |
| Accuracy error | 0.90 % 1.20 % 3.00 % |
| Volume Range | 5 - 50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| Accuracy error | 0.60 % 0.90 % 2.00 % |
| Volume Range | 10 - 100 μL |
| Increment | 1 μL |
| Test Volume | 100 μL 50 μL 10 μL |
| Accuracy error | 0.80 % 1.00 % 3.00 % |
| Volume Range | 20 - 200 μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 20 μL |
| Accuracy error | 0.60 % 0.80 % 3.00 % |
| Volume Range | 50 - 200μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 50 μL |
| Accuracy error | 0.60 % 0.80 % 1.00 % |
| Volume Range | 100 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 100 μL |
| Accuracy error | 0.60 % 0.70 % 2.00 % |
| Volume Range | 200 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 200 μL |
| Accuracy error | 0.60 % 0.70 % 0.90 % |
| Volume Range | 1000 - 5000 μL |
| Increment | 50 μL |
| Test Volume | 5000 μL 2500 μL 1000 μL |
| Accuracy error | 0.50 % 0.60 % 0.70 % |
| No of Channels | 8 |
| Volume Range | 0.5 -10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 8 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 8 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| No of Channels | 12 |
| Volume Range | 0.5-10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 12 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 12 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| No of Channels | 8 |
| Volume Range | 0.5 -10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 8 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 8 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| No of Channels | 12 |
| Volume Range | 0.5-10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 12 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 12 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| Volume Range | 0.1 - 2.5 μL |
| Increment | 0.05 μL |
| Test Volume | 2.5 μL 1.25 μL 0.25 μL |
| Accuracy error | 2.50 % 3.00 % 12.00 % |
| Volume Range | 0.5 - 10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| Accuracy error | 1.00 % 1.50 % 2.50 % |
| Volume Range | 2 - 20 μL |
| Increment | 0.5 μL |
| Test Volume | 20 μL 10 μL 2 μL |
| Accuracy error | 0.90 % 1.20 % 3.00 % |
| Volume Range | 5 - 50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| Accuracy error | 0.60 % 0.90 % 2.00 % |
| Volume Range | 10 - 100 μL |
| Increment | 1 μL |
| Test Volume | 100 μL 50 μL 10 μL |
| Accuracy error | 0.80 % 1.00 % 3.00 % |
| Volume Range | 20 - 200 μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 20 μL |
| Accuracy error | 0.60 % 0.80 % 3.00 % |
| Volume Range | 50 - 200μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 50 μL |
| Accuracy error | 0.60 % 0.80 % 1.00 % |
| Volume Range | 100 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 100 μL |
| Accuracy error | 0.60 % 0.70 % 2.00 % |
| Volume Range | 200 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 200 μL |
| Accuracy error | 0.60 % 0.70 % 0.90 % |
| Volume Range | 1000 - 5000 μL |
| Increment | 50 μL |
| Test Volume | 5000 μL 2500 μL 1000 μL |
| Accuracy error | 0.50 % 0.60 % 0.70 % |
| Volume Range | 2 - 10 mL |
| Increment | 0.1 mL |
| Test Volume | 10 mL 5 mL 2 mL |
| Accuracy error | 0.60 % 1.20 % 3.00 % |
Pipette Pumps Features a rotating thumb wheel for drawing up or dispensing liquid. Syringe-type, for easy, one-hand control of filling and delivery from conventional pipets. Offered in three color-coded sizes. Provides relaxed, precise pipetting. Economical and resilient manual pipette.