Radio Frequency Identification Water Purification System LRFW-B13 is a 80 L capacited revolutionary, modular design which helps in elimination of large amount of salts and other minerals from water using 2 stages of RO with the least TOC level i.e. < 3 ppb. Here the concentrate or reject stream is fed into a second RO system to maximize water recovery. The unique feature of this model is that it’s equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance
Specifications
Output of Pure water | ≥ 40 L / hr. |
Process | Double Pass RO system |
Configuration | Floor standing |
Water Tank capacity | 80 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 3 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 450 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 45 kg |
Features
Radio Frequency Identification Chip integrated
Advanced Double Pass reverse osmosis system for excellent water quality
2 levels of water purification with high recovery rate
Online monitoring of water resistance
Equipped with 80 L water holding tank
Least TOC level < 3ppb
Source of inlet water – Tap water
Floor Standing model
LCD display to monitor the intake of water pressure and various parameters intuitively
Programmed water shortage protection alarm
Anti-fouling RO membrane prevention programme
Ease of cleansing , disinfecting and draining waste water
Micro filter membrane to filter out pollutants
Automatic RO membrane antiscale flushing to extend the life of the RO membrane
Applications
Used in PCR / DNA preparation, HPLC, LC-MS, electrophoresis, chemical analysis experiment, protein analysis
Request Quote
Output of Pure water | ≥ 10 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Process | Double Pass RO system |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. Cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Pyrogens | < 0.02 EU / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 100 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 39 kg |
Output of Pure water | ≥ 20 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Process | Double Pass RO system |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. Cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Pyrogens | < 0.02 EU / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 150 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 39 kg |
Output of Pure water | ≥ 30 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Process | Double Pass RO system |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. Cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Pyrogens | < 0.02 EU / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 39 kg |
Output of Pure water | ≥ 40 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 80 L |
Configuration | Floor Standing |
Process | Double Pass RO system |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. Cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Pyrogens | < 0.02 EU / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 39 kg |
Output of Pure water | ≥ 10 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 10-16 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 150 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 40 kg |
Output of Pure water | ≥ 20 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 10-16 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 40 kg |
Output of Pure water | ≥ 30 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 10-16 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 450 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 40 kg |
Output of Pure water | ≥ 40 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 80 L |
Configuration | Floor Standing |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 10-16 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 20 ppb |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 450 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 40 kg |
Output of Pure water | ≥ 10 L / hr. |
Water Type | Type III |
Configuration | Benchtop |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Conductivity at 25 °C | < 5 µs / cm |
pH | 5.0 – 7.5 |
Oxidizabes | ≤ 0.4 mg / L |
Evaporation residue | ≤ 2.0 mg / L |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 150 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 35 kg |
Output of Pure water | ≥ 20 L / hr. |
Water Type | Type III |
Configuration | Benchtop |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Conductivity at 25 °C | < 5 µs / cm |
pH | 5.0 – 7.5 |
Oxidizabes | ≤ 0.4 mg / L |
Evaporation residue | ≤ 2.0 mg / L |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 35 kg |
Output of Pure water | ≥ 30 L / hr. |
Water Type | Type III |
Configuration | Benchtop |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Conductivity at 25 °C | < 5 µs / cm |
pH | 5.0 – 7.5 |
Oxidizabes | ≤ 0.4 mg / L |
Evaporation residue | ≤ 2.0 mg / L |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 350 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 35 kg |
Output of Pure water | ≥ 40 L / hr. |
Water Type | Type III |
Configuration | Floor Standing |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Conductivity at 25 °C | < 5 µs / cm |
pH | 5.0 – 7.5 |
Oxidizabes | ≤ 0.4 mg / L |
Evaporation residue | ≤ 2.0 mg / L |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 350 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 35 kg |
Output of Pure water | ≥ 10 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 3 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 150 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 45 kg |
Output of Pure water | ≥ 20 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 3 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 45 kg |
Output of Pure water | ≥ 30 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 3 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 450 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 45 kg |
Output of Pure water | ≥ 50 L / hr. |
Process | Double Pass RO system |
Configuration | Floor Standing |
Water Tank capacity | 80 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 3 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 550 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 45 kg |
Output of Pure water | ≥ 10 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 10 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | > 150 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 41 kg |
Output of Pure water | ≥ 20 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 10 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | > 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 41 kg |
Output of Pure water | ≥ 30 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 10 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | > 450 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 41 kg |
Output of Pure water | ≥ 40 L / hr. |
Process | Double Pass RO system |
Configuration | Floor standing |
Water Tank capacity | 80 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 10 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | > 450 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 41 kg |
Water quality | One stage (Type I) |
Feed water | RO water /Distilled water Water temperature: 5 ~ 40℃ |
Conectivity | |
Resistivity | 18.25 MΩ.cm @ 25 ℃ |
TOC | < 5ppb |
Bacteria | < 0.1 cfu/ml |
Endotoxin | < 0.001 EU/ml |
Particle | ( > 0.22μm) |
Absorbance | (254nm,1cm optical distance) < 0.001 EU/ml |
Reactive Silica(SiO2) | < 0.01 ppm |
RNases | < 0.01 ng/ml |
DNases | < 4 pg/μl |
Temperature | 5 ℃ ~ 40 ℃ |
Humidity | 10 % ~ 80 % |
Water production rate | Type 1 water flow rate: 1-1.5 L/min |
Micro filtration | Millipore Millipak 0.22μm membrane or hollowed fiber membrane filter |
Power supply | 230 V/50 Hz 150 W |
Main body Dimension (L × W × H) | 340 × 550 × 530 mm (bench type) |
Water quality | Two stage(Type III and type I) |
Feed water | Tap waterTDS≤400ppm Water temperature: 5-40℃ Type 3 water ≥10L/h |
Conectivity | |
Resistivity | 18.25 MΩ.cm @ 25 ℃ |
TOC | < 5ppb |
Bacteria | < 0.1 cfu/ml |
Endotoxin | < 0.001 EU/ml |
Particle | ( > 0.22μm) |
Absorbance | (254nm,1cm optical distance) < 0.001 EU/ml |
Reactive Silica(SiO2) | < 0.01 ppm |
RNases | < 0.01 ng/ml |
DNases | < 4 pg/μl |
Temperature | 5 ℃ ~ 40 ℃ |
Humidity | 10 % ~ 80 % |
Water production rate | Type 1 water flow rate: 1-1.5L/min |
Micro filtration | Millipore Millipak 0.22μm membrane or hollowed fiber membrane filter |
Power supply | 230 V/50 Hz 150 W |
Main body Dimension (L × W × H) | 340 × 550 × 530 mm (bench type) |
Output 2nd stage RO water | 90 liters/hour |
Output ultrapure water | Up to 2 liters/minute (when tank is full) |
Ultrapure Water Quality | Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm): |
RO Water Quality | Conductivity 1st stage RO water: Feed water Conductivity ×5 % Conductivity 2nd stage RO water: 1 to 5 µs/cm |
Feed water requirements | Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2 |
Dimension | 610 × 585 × 1580 mm |
Power Consumption | 480 W |
Power Supply | AC110 to 240 V, 50/60 Hz |
Weight | about 75 kg |
Standard configuration | Main body (Including 1 set of cartridge) +20 liters Pressure Tank and 20 liters pressure tank |
Output 2nd stage RO water | 90 liters/hour |
Output ultrapure water | Up to 2 liters/minute (when tank is full) |
Ultrapure Water Quality | Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm): |
EDI | Resistivity >10.2 M Ω cm TOC: < 30ppb Silicone rejection rate: >99.9 % |
RO Water Quality | Conductivity 1st stage RO water: Feed water Conductivity ×5 % Conductivity 2nd stage RO water: 1 to 5 µs/cm |
Feed water requirements | Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2 |
Dimension | 610 × 585 × 1580 mm |
Power Consumption | 480 W |
Power Supply | AC110 to 240 V, 50/60 Hz |
Weight | about 75 kg |
Standard configuration | Main body (Including 1 set of cartridge) +20 liters Pressure Tank and 20 liters pressure tank |
Output | 30 liters/hour |
Flow rate | Up to 2 liters/minute (with pressure tank) |
Pure water outlet | 2 reverse osmosis water, deionized water |
Deionized Water Quality | Resistivity: 16 to 18.2 M Ω cm Bacteria: N/A Particle (>0.1 µm): N/A |
RO Water Quality | Ion rejection rate: 97 % to 99% (new RO membrane) Organic rejection rate: >99 %, when MW >200 Dalton Particles and bacteria rejection rate: >99 % |
Feed water requirements | Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2 |
Dimension | 410 × 220 × 420 mm |
Power Consumption | 72 W |
Power Supply | AC100 to 240 V, 50/60 Hz |
Weight | about 18 kg |
Standard configuration | Main body (Including 1 set of cartridge) +15 liters pressure tank+ TDS/conductivity test pen |
Output | 30 liters/hour |
Flow rate | Up to 2 liters/minute (with pressure tank) |
Pure water outlet | 2 reverse osmosis water, deionized water |
Deionized Water Quality | Resistivity: 16 to 18.2 M Ω cm Bacteria: N/A Particle (>0.1 µm): N/A |
RO Water Quality | Ion rejection rate: 97 % to 99% (new RO membrane) Organic rejection rate: >99 %, when MW >200 Dalton Particles and bacteria rejection rate: >99 % |
Feed water requirements | Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2 |
Dimension | 340 × 500 × 560 mm |
Power Consumption | 72 W |
Power Supply | AC100 to 240 V, 50/60 Hz |
Weight | about 18 kg |
Standard configuration | Main body (Including 1 set of cartridge) +12 liters pressure tank |