Sample Concentrator LSCO-B10 is a microprocessor based PID controlled instrument using high-purity aluminium as heat conducting medium having temperature range of +5 ℃ to 160 ℃. The models have airflow adjustment system to concentrate the samples and have provisions of concentrating around 12 samples at a time.
Specifications
Number of samples | 12 wells |
Nitrogen Flow Rate | 15 L/min |
Nitrogen Pressure | 0.1 MPa |
Block Quantity | 1 |
Temperature Control Range | Room temp. +5 ℃ to 160 ℃ |
Needle length | 150 mm |
Temp. uniformity | ≤ ± 0.5 ℃ |
Temp. accuracy | ±0.5 ℃ (at 40 ℃) ± 1 ℃ (at 120 ℃) |
Display accuracy | 0.1 ℃ |
Heating time | ≤ 15 min (from 25 ℃ to 160 ℃) |
Timing range | 1 min - 99 h 59 min |
Voltage | AC 220 V or AC 110 V, 50 / 60 Hz |
Power Consumption | 300 W |
Dimension | 260 x 220 x 475 mm |
Weight | 6 kg |
Features
Easy operation
Microprocessor based PID controller
Precised temperature control
High-purity aluminium as heat conducting medium
Adjustable airflow rate
Large number of samples can be blowed at a time
Individualistic blowing of sample
Applications
Sample Concentrator is used for sample preparation, drug screening, hormone assays, chromatographic analysis and scintillation counting.
Optional Accessories
Block no. | Diameter of tubes | Capacity |
SCB-01 | 10 mm | 12 |
SCB-02 | 12 mm | 12 |
SCB-03 | 13 mm | 12 |
SCB-04 | 15 mm | 12 |
SCB-05 | 16 mm | 12 |
SCB-06 | 19 mm | 12 |
SCB-07 | 20 mm | 12 |
Request Quote
Number of samples | 3 to 24 wells |
Nitrogen Flow Rate | 15 L/min |
Nitrogen Pressure | 0.02 MPa (Gas needle ≤ 16pcs) 0.05MPa (Gas needle > 16pcs) |
Block Quantity | 1 |
Temperature Control Range | Room temp. +5 ℃ to 160 ℃ |
Needle length | 150 mm |
Temp. uniformity | ≤ ± 0.5 ℃ |
Temp. accuracy | ±0.5 ℃ (at 40 ℃) ± 1 ℃ (at 120 ℃) |
Display accuracy | 0.1 ℃ |
Heating time | ≤ 15 min (from 25 ℃ to 160 ℃) |
Timing range | 1 min - 99 h 59 min |
Voltage | AC 220 V or AC 110 V, 50 / 60 Hz |
Power Consumption | 300 W |
Dimension | 260 x 220 x 450 mm |
Weight | 7 kg |
Number of samples | 3 to 24 wells |
Nitrogen Flow Rate | 15 L/min |
Nitrogen Pressure | 0.02 MPa (Gas needle ≤ 16pcs) 0.05MPa (Gas needle > 16pcs) |
Block Quantity | 2 |
Temperature Control Range | Room temp. +5 ℃ to 160 ℃ |
Needle length | 150 mm |
Temp. uniformity | ≤ ± 0.5 ℃ |
Temp. accuracy | ±0.5 ℃ (at 40 ℃) ± 1 ℃ (at 120 ℃) |
Display accuracy | 0.1 ℃ |
Heating time | ≤ 15 min (from 25 ℃ to 160 ℃) |
Timing range | 1 min - 99 h 59 min |
Voltage | AC 220 V or AC 110 V, 50 / 60 Hz |
Power Consumption | 500 W |
Dimension | 260 x 220 x 475 mm |
Weight | 7.5 kg |
Number of samples | 12 wells |
Nitrogen Flow Rate | 15 L/min |
Nitrogen Pressure | 0.1 MPa |
Block Quantity | 2 |
Temperature Control Range | Room temp. +5 ℃ to 160 ℃ |
Needle length | 150 mm |
Temp. uniformity | ≤ ± 0.5 ℃ |
Temp. accuracy | ±0.5 ℃ (at 40 ℃) ± 1 ℃ (at 120 ℃) |
Display accuracy | 0.1 ℃ |
Heating time | ≤ 15 min (from 25 ℃ to 160 ℃) |
Timing range | 1 min - 99 h 59 min |
Voltage | AC 220 V or AC 110 V, 50 / 60 Hz |
Power Consumption | 500 W |
Dimension | 260 x 220 x 475 mm |
Weight | 7.5 kg |