Ask An Expert

Handheld C2H4 Ethylene Gas Detector LEGD-A10
Sampling: With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas: Ethylene C2H4
Measure Range: 0 to 1000 ppm
Resolution: 1ppm
Portable 2 in 1 gas detector LPTG-A10
Sampling method: Diffusion
Sensor type: CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range: CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy: CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Portable Multiple Gas Detector LPMG-A10
Sampling Method: Diffusion
Working conditions:
Temperature -20 to 50°C
Pressure 0.9 to 1.1 (standard atmospheric pressure)
Humidity 10 to 95 % RH (no dew condensation)
Explosion proof grade: Exia II CT3
Protection grade: IP65
Portable infrared gas detector LIGD-A10
Measurement principle: Non-dispersive infrared  (NDIR)
Gas Detected: SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty: <1.5 % F.S
Detection Resolution: 0.1ppm
Portable NO<sub>2</sub> Gas Detector LPSG-A21
Gas detected: NO2
Detection principle: Electrochemistry
Sampling method: Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range: 0 to1000 ppm
Portable SO<sub>2</sub>Gas Detector LPSG-A20
Gas detected: Sulfur dioxide SO2
Detection principle: Electrochemistry
Sampling method: Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range: 0 to1000 ppm
Portable Single Gas Detector LPSG-A10
Sampling method: Diffusion
Measurement principle: Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
Detector gas: Flammable gases, oxygen gas, toxic and harmful gases
Response time:
CO2 < 10 s
O2, flammable gases < 20 s
CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
HCN, NH3, PH3 < 100 s
Portable 10 in 1 Multi Gas Detector LMGD-A10
Gas Detected: O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
Detection principle: Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
Measurement Range: O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Resolution: O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM
Portable Nitrogen N2 Gas Detector LNGD-A10
Gas Detected: Nitrogen N2
Detection principle: Electrochemical principles
Measurement Range: 0 to 100 %.Vol
Resolution: 0.01 %VOL