Portable Nitrogen N2 Gas Detector LNGD-A10 take sample by built-in pump and has measuring range of 0 to 100 % VOL, fast and accurate measurement. Features with stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, and flow range is up to 0 to 500 mL/min. It display multiple display modes selectable, multi-channel data mode, multi-curve mode, multi-channel data + multi-curve mode, single channel + single curve mode. Designed with 3.5-inch high-definition color screen, high resolution, wide viewing angle. The air supply system of up to three pumps can switch the pump arbitrarily, blocking the loss of the cross-gas to the relevant sensor and prolonging the service life of the sensor. It support gas concentration data display, gas concentration real-time curve display mode arbitrary switching.
Portable Nitrogen N2 Gas Detector is used in pharmaceutical, medical, food, corrosion, Disinfection, chemical fertilizers, resins, adhesives and across pesticides, raw materials, samples, process and breeding plants, waste treatment plants, perm places
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Resolution | 1ppm |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Detection Resolution | 0.1ppm |
| Gas Detected | O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3 |
| Detection principle | Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC) |
| Measurement Range | O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM |
| Resolution | O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM |
| Sampling Method | Diffusion | ||||||
| Working conditions |
|
||||||
| Explosion proof grade | Exia II CT3 | ||||||
| Protection grade | IP65 |
| Sampling method | Diffusion | ||||
| Measurement principle | Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas) | ||||
| Detector gas | Flammable gases, oxygen gas, toxic and harmful gases | ||||
| Response time |
|
| Gas detected | Sulfur dioxide SO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measure range | 0 to1000 ppm |
| Gas detected | NO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measure range | 0 to1000 ppm |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Detection accuracy | CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale) |
| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error) ± 1 % |
| Operating temperature range | 0 °C ∼ 50 °C |
| Operational humidity | ˂ 85 RH |
| Measuring range | ± 500 Pa |
| Repeatability | ± 0.2 % FS |
| Resolution | 0.1 Pa |
| Sampling rate | 0.5 s |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Humidity range | 0 % ∼ 100 % RH |
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Resolution | 0.001 ppm |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |
| Measuring time | 10 seconds |
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |