Flame Atomic Absorption Spectrophotometer LAAS-A12

Flame Atomic Absorption Spectrophotometer LAAS-A12 is a microprocessor controlled instrument based on analysis of metal ions by flames and their absorption at a wavelength of 190 to 900 nm. The C-T monochromator and variance of bandwidth provides user flexibility. Equipped with safety features like auto shut on acetylene gas leakage makes this instrument user friendly

Specifications Features Applications Get Quote View Catalog

Specifications

Wavelength range 190 nm ~ 900 nm
Spectral bandwidth 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
Wavelength accuracy ± 0.25 nm
Wavelength repeatability 0.15 nm
Temperature 15 °C to 30 °C
Humidity ≤ 75 %
Monochromator C-T
Optical system 1800 lines / mm
Detector Photomultiplier
Quality concentration 3.0 μg / ml
Absorbance > 0.300 Abs
LOQ (Cu) 0.006 μg / ml
Burner 100 mm metallic titanium
Repeatability RS D ≤ 1 %
Sprayer Glass, plastic and stainless steel
Atomization chamber Corrosion resistant
Safety protection Turn off alarm for acetylene gas leakage
Measurement method Air-acetylene flame / hydride generator atomic absorption method
Concentration calculation Standard curve, automatic matching, standard addition 
Power 150 W
Power supply AC 220 V / 50 Hz
Dimensions 1000 x 350 x 390 mm
Weight 70 Kg

Features

Auto-setting for flow, ignition and flameout protection

Automatic control for scanning wavelength and peak

Single slit titanium metal burner

Photomultiplier detector

Corrosion resistant atomizing chamber

Glass, plastic and stainless steel sprayer

Real time monitoring for flame and pressure

Auto shut on acetylene gas leakage for end user safety

Applications

Used for analysis of metal element in opaque materials, life science, detection of trace metal elements in food, medical etc.

Request Quote

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B30

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Double beam 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0003 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise 0.0005 A @ 500 nm
Display 10.1 inches TFT colored capacitive touch screen
Baseline flatness ± 0.002 A
Printer port Parallel port
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm single hole cell holder
Dimension 810 × 660 × 390 mm
Gross weight 27 kg

Double Beam UV/Vis Spectrophotometer LUS-B31

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Double beam 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0003 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise 0.0005 A @ 500 nm
Display 10.1 inches TFT colored capacitive touch screen
Baseline flatness ± 0.001 A
Printer port Parallel port
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm single hole cell holder
Dimension 810 × 660 × 390 mm
Gross weight 27 kg
Double Beam UV/Vis Spectrophotometer LUS-B32
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Double beam 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0003 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise 0.0005 A @ 500 nm
Display 10.1 inches TFT colored capacitive touch screen
Baseline flatness ± 0.001 A
Printer port Parallel port
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm single hole cell holder
Dimension 880 × 690 × 520 mm
Gross weight 45 kg
Double Beam UV/Vis Spectrophotometer LUS-B16
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.1 nm
Photometric Range (-4) ~ 4 A
Photometric Mode T,A,C,E
Photometric Accuracy ± 0.3 % τ(0 - 100 % τ) ; ± 0.002 A (0 ~ 0.5 A) ; ± 0.003 A(0.5 A ~ 1 A)
Photometric Repeatability 0.15 % τ(0 -100 % τ); ± 0.001 A(0 ~ 0.5 A) ; ± 0.0015 A(0.5 A ~ 1 A)
Transmittance accuracy
Transmittance repeatability
Detector
Light Source
Stray Light ≤ 0.03 % τ (220 nm NaI, 340 nm NaNO2)
Stability
Data Output Port
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 560 × 450 × 230 mm
Noise ± 0.0002A @500nm
Weight 28 kg
Gross Weight
Net Weight
Power 120 W
Display LCD 6 inches blue LCD
Optical System Double beam
Baseline Linearity
Baseline Drift
Baseline Flatness ± 0.001 A
Printer Port
Packing Size
Software
Packing Weight

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A10

Cuvette
Temperature
PC
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm
Wavelength Resolution ≤ 3 nm (FWHM at Hg 546 nm)
Path length of cuvette
Minimum Sample size 0.5 - 2.0 µl
Absorbance range 0.02 - 90 A (10mm equivalent)
Precision of wavelength
Absorbance precision 0.003 Abs
Absorbance accuracy 1 % ( 7.332 Abs at 260 nm)
Light source Xenon flash lamp
Measurement time < 8 s
Operating Voltage 24 V DC
Sample Pedestal Material Aluminum alloy and Quartz fiber
Detector Type 3864-element linear silicon CCD array
Screen
Software Compatibility Windows 7, Windows XP
Detects nucleic acid up to 2 - 4500 ng/µL (dsDNA)
Detects protein up to
Data Output
Operating Power Consumption 20 W
Standby Power Consumption 5 W
Dimension 200 x 250 x 166 mm
Weight 2.6 kg

Nano Spectrophotometer LNS-A21

Cuvette
Temperature
PC
Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Path length of cuvette
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.00 2 ~ 75 A (150, 300 optional, 10mm equivalent absorbance)
Precision of wavelength
Absorbance precision 0.002 Abs
Absorbance accuracy 1 % (0.76 absorbance at 350 nm)
Light source Xenon flash lamp
Measurement time < 5 s
Operating Voltage
Sample Pedestal Material
Detector Type 2048-element linear silicon CCD
Screen
Software Compatibility
Detects nucleic acid up to 4 - 3750 ng/µL (7500,15000 optional, dsDNA)
Detects protein up to 0.01 - 100 mg/mL (200, 400 optional, BSA)
Data Output
Operating Power Consumption
Standby Power Consumption
Dimension 240 x 210 x 110 mm
Weight 1.92 kg
Nano Spectrophotometer LNS-B11
Cuvette
Temperature
PC
Wavelength range 230 nm, 260 nm, 280 nm
Path length 1.0 mm, 0.2 mm
Wavelength accuracy
Wavelength Resolution
Path length of cuvette
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.2 - 75A (10 mm equivalent absorbance)
Precision of wavelength
Absorbance precision 0.002 Abs
Absorbance accuracy 0.01
Light source Xenon flash lamp
Measurement time < 5 s
Operating Voltage
Sample Pedestal Material
Detector Type
Screen
Software Compatibility
Detects nucleic acid up to 10 - 3750 ng/µL (dsDNA)
Detects protein up to 0.5 - 110 mg/mL (BSA)
Data Output
Operating Power Consumption
Standby Power Consumption
Dimension 240 x 220 x 140 mm
Weight 2.35 kg
Nano Spectrophotometer LNS-C10
Cuvette No
Temperature
PC Inbuilt
Wavelength range 190 - 850 nm
Path length 1 mm, 0.2 mm ,0.04 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Path length of cuvette NA
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0 to 500 Abs
Precision of wavelength ± 1 nm
Absorbance precision 0.002 ~ 400 Abs (10 mm)
Absorbance accuracy 1 % (0.76 absorbance at 350 nm)
Light source Xenon flash lamp
Measurement time < 5 s
Operating Voltage
Sample Pedestal Material Stainless steel and quartz fiber
Detector Type 2048-element linear silicon CCD
Screen Color LCD Touchscreen display
Software Compatibility Win7 (64-bit operating system)/Win 8
Detects nucleic acid up to 0.4 ~ 19000 ng/µL (dsDNA)
Detects protein up to 0.01 ~ 400 mg/mL (BSA)
Data Output
Operating Power Consumption
Standby Power Consumption
Dimension 350 x 240 x 220 mm
Weight 5.2 kg

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Vis Spectrophotometer LUS-A50

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Single beam 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0005 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise 0.0005 A @ 500 nm
Display 10.1 inches TFT colored capacitive touch screen
Baseline flatness ± 0.002 A
Printer port Parallel port
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm manual 4 cell holder
Dimension 810 × 660 × 390 mm
Gross weight 27 kg

Single Beam UV/Vis Spectrophotometer LUS-A51

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Single beam 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0005 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise 0.0005 A @ 500 nm
Display 10.1 inches TFT colored capacitive touch screen
Baseline flatness ± 0.001 A
Printer port Parallel port
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm manual 4 cell holder
Dimension 810 × 660 × 390 mm
Gross weight 27 kg
Single Beam UV/Vis Spectrophotometer LUS-A52
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Single beam 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0005 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise 0.0005 A @ 500 nm
Display 10.1 inches TFT colored capacitive touch screen
Baseline flatness ± 0.001 A
Printer port Parallel port
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm manual 4 cell holder
Dimension 810 × 660 × 390 mm
Gross weight 27 kg
Single Beam UV/Visible Spectrophotometer LUS-A10
Wavelength Range 190 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Photometric Range 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C
Photometric Mode
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.2 % T
Transmittance accuracy
Transmittance repeatability
Detector Silicon Photodiode
Light Source Deuterium & Tungsten Halogen Lamp
Stray Light ≤ 0.05 % T at 220 nm, 360 nm
Stability 0.002 A / h at 500 nm
Data Output Port USB
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions
Noise ± 0.001 A
Weight
Gross Weight
Net Weight
Power
Display LCD
Optical System Single Beam (1200 lines / mm grating)
Baseline Linearity
Baseline Drift
Baseline Flatness ± 0.001 A
Printer Port Parallel Port
Packing Size 860 x 660 x 465 mm
Software
Packing Weight 35 kg

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Vis Spectrophotometer LVS-A10

Wavelength Range 330 to 1000 nm
Setting Wavelength
Spectral Bandwidth 5 nm
Wavelength Accuracy ± 2 nm
Wavelength Repeatability ≤ 1.0 nm
Photometric Range T: 0 to199.9%, A: -0.3 to2.5 Abs, F; 0 to 9999, C: 0 to 9999
Photometric Mode
Photometric Accuracy ± 0.5 % T
Photometric Repeatability ≤ 0.2 % T
Transmittance accuracy
Transmittance repeatability
Detector Silicone photo diode
Light Source 20 W, 12 V Tungsten lamp
Stray Light ≤ 0.5 % T (360 nm)
Stability Dark current: ≤ 0.2 % T, Light Current: ≤ 0.5 % T
Data Output Port
Power Requirement 220 V ± 20 V, 50 Hz ± 1 Hz
Dimensions 470 × 350 × 200 mm
Noise
Weight 8 kg
Gross Weight
Net Weight
Power
Display LCD
Optical System Single beam, C-T grating monochromator 1200 lines/ mm
Baseline Linearity
Baseline Drift
Baseline Flatness
Printer Port
Packing Size
Software
Packing Weight

Vis Spectrophotometer LVS-A11

Wavelength Range 335 ~ 1000 nm
Setting Wavelength
Spectral Bandwidth 4 nm
Wavelength Accuracy ± 2 nm
Wavelength Repeatability 1 nm
Photometric Range T: 0 ~ 199.9 % , A: (-0.3) ~ 2.5A bs, F: 0 ~ 9999, C: 0 ~ 9999
Photometric Mode
Photometric Accuracy ± 0.5 % T
Photometric Repeatability 0.2 % T
Transmittance accuracy
Transmittance repeatability
Detector Silicon photo diode
Light Source Tungsten lamp (Socket Type, 20W / 12V, 2000h)
Stray Light ≤ 0.5 % T (360 nm)
Stability ≤ 0.5 % T / 5min
Data Output Port
Power Requirement 220 V / 50 Hz
Dimensions 385 × 330 × 185 mm
Noise
Weight 10 kg
Gross Weight
Net Weight
Power
Display LCD
Optical System 1200 lines / mm grating
Baseline Linearity
Baseline Drift
Baseline Flatness
Printer Port
Packing Size
Software
Packing Weight
Vis Spectrophotometer LVS-B10
Wavelength Range 325 ~ 1000 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 1.0 nm
Wavelength Repeatability ≤ 0.2 nm
Photometric Range (-0.3) ~ 3 A
Photometric Mode
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.15 % τ
Transmittance accuracy
Transmittance repeatability
Detector Import Silicon Photodiode Detector
Light Source Import Tungsten Lamp
Stray Light ≤ 0.05 % τ
Stability 0.001 A / h at 500 nm
Data Output Port
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 460 × 330 × 210 mm
Noise
Weight 11 kg
Gross Weight
Net Weight
Power 120 W
Display LCD
Optical System
Baseline Linearity
Baseline Drift
Baseline Flatness
Printer Port
Packing Size
Software
Packing Weight
Vis Spectrophotometer LVS-C10
Wavelength Range 320 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 4 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Repeatability ≤ 0.2 nm
Photometric Range (-0.3) ~ 3 A
Photometric Mode
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.15 % τ
Transmittance accuracy
Transmittance repeatability
Detector Import Silicon Photodiode Detector
Light Source Import Tungsten Lamp
Stray Light ≤ 0.05 % τ
Stability 0.001 A / h 30 min at 500 nm
Data Output Port
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 480 × 350 × 220 mm
Noise
Weight 11 kg
Gross Weight
Net Weight
Power 120 W
Display LCD Display resolution 128 × 64 Dots LCD
Optical System
Baseline Linearity
Baseline Drift
Baseline Flatness
Printer Port
Packing Size
Software
Packing Weight

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Baseline stability ≤ 0.002 Abs / 30 min
Characteristic concentration of copper 0.02 μg / ml / 1 %
Detection limit of copper 0.004 μg / ml
Measurement Repeatability 0.005
Grating 1800 lines / mm
Inflamer All-metal titanium burner
Atomizer Efficient glass atomizer
Lamp stand 8 lamps automatic turret, automatic alignment
D2 Background calibration ability 1 A ≤ 30 times correction ability
Dimensions 700 × 550 × 450 mm
Net weight 75 Kg
Power supply 220 V ± 22 V AC
Acetylene air burner 100 mm
Ignition dynamic baseline drift ≤ 0.006 Abs / 30 min
Characteristic viscocity ≤ 0.025 μg / ml / 1 %
Standard deviation of the accuracy ≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
Protection system Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner

Atomic Absorption Spectrophotometer LAAS-A11

Monochromator
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Baseline drift ± 0.004 Abs / 30 min
Grating groove density
Sample Volume
The volume of sample
Repeated Sampling Frequency
Cleaning and waste container volume
Absorbance Range
The Program
Temperature Range
Detector
Heating Mode
Temperature Control Method
Temperature Control
Resolution < 40 %
Lamp holder
Lamp current adjustment range
Lamp power supply mode
Optical System
Atomization Chamber
Characteristics Volume
Characteristic concentration (Cu) ≤ 0.04 mg / ml / 1 %
Detection Limit
Detection Limit (Cu) 0.008 mg/ml
Background calibration ability Greater than 30 times
Burner
Nebulizer
Precision
Ignition Type
Sprayer
Room Spray
Sample Tray
The Smallest Lincrement
Safety measures
Gas Control
Measurement
Concentration calculation
The Cooling Water
The number of repeated measurements
Print results
Software Environment
Operating temperature
Working humidity
Power supply 220 V / 3 A, 50 Hz
Power (VAC)
Gross Weight 160 kg
Weight
Dimension (L × W × H) 1220 x 770 x 730 mm
Atomic Absorption Spectrophotometer LAAS-A20
Monochromator
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
Grating groove density
Sample Volume
The volume of sample
Repeated Sampling Frequency
Cleaning and waste container volume
Absorbance Range 0 - 4 A
The Program
Temperature Range
Detector Imported photomultiplier tube
Heating Mode
Temperature Control Method
Temperature Control
Resolution
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Lamp current adjustment range
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit
Detection Limit (Cu) 0.002 μg/mL
Background calibration ability
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Sprayer
Room Spray
Sample Tray
The Smallest Lincrement
Safety measures
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Software Environment
Operating temperature
Working humidity
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
Power (VAC)
Gross Weight
Weight
Dimension (L × W × H)
Atomic Absorption Spectrophotometer LAAS-A21
Monochromator
Wavelength range 180 – 900 nm
Spectral Bandwidth 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic)
Grating groove density
Sample Volume
The volume of sample
Repeated Sampling Frequency
Cleaning and waste container volume
Absorbance Range 0 - 4 A
The Program
Temperature Range
Detector
Heating Mode
Temperature Control Method
Temperature Control
Resolution
Lamp holder ≤ 3 lamps automatic turret, automatic alignment
Lamp current adjustment range
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit
Detection Limit (Cu) 0.002 μg/mL
Background calibration ability
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Sprayer
Room Spray
Sample Tray
The Smallest Lincrement
Safety measures
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Software Environment
Operating temperature
Working humidity
Power supply
Power (VAC)
Gross Weight
Weight
Dimension (L × W × H)

Table Top Spectrophotometer

Table Top Spectrophotometer LTS-A15

Wavelength Range 400 nm to 700 nm
Wavelength Interval 10 nm
Sensor High sensitivity silicon photodiode
Light Source LED
Working Temperature Range 0 ℃ to 45 ℃
Measurement Aperture 11 mm
Geometry 45/0 (45 ringed shaped illumination, 0 degree viewing)
Observer Viewing Angles 2°/ 10°
Repeatability Standard deviation within 0.08% Chromaticity Value; ΔE*ab
Inter-Instrument Agreement ΔE*ab within 0.2 (BCRA Series II, average measurement of the 12 tiles)
Illuminants A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30.DLF,NBF,TL83,TL84.U35
Color Spaces CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance Hunter lab, Munsell MI,CMYK,RGB,HSB
Color Difference ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 shade sort
Other Indices WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby); YI(ASTM D1925, ASTM E313-00,ASTM E313-73); Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness ISO Brightness, 8 gloss, A density, T density, M density, E density
Standards CIE-15-2004; ASTM-D523; ASTM-D2244; ASTM D2457
Illumination Life time 10 years 3 million test
Interface USB
Screen Size 5 Inches Color Screen
Storage Memory 20000 test results
Battery Capacity Rechargeable, 1000 continuous tests
Power 7.4 V/ 6000 mAh
Dimensions (L × W × H) 350 × 300 × 200 mm
Weight 4.5 kg (without battery)

Table Top Spectrophotometer LTS-A16

Wavelength Range 360 nm to 780 nm
Wavelength Pitch 10 nm
Sensor Silicon Photodiode Array
Grating Method Concave Grating
Sphere Diameter 152 mm
Half Band Width 5 nm
Reflectance Range 0 to 200 %
Resolution 0.0001
Light Source Pulse Xenon Lamp LED
UV Measurement Include UV, 400nm cut, 420nm cut, 460nm cut
Operating Temperature 5 ℃ to 40 ℃
Storage Temperature -20 ℃ to 45 ℃
Relative Humidity 80 % RH (at 35 ℃)
Measurement Time SCI/SCE < 2 SCI+SCE < 4s
Measurement Aperture Reflectance: XLAV Φ30mm LAV 18mm,MAV Φ11mm SAV Φ6mm Transmittance:Φ25mm (Auto aperture size recognition)
Viewing Angles 2° and 10°
Transmittance Sample Size No limit on sample width and height Thickness ≤ 50mm
Repeatability XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1% XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration
Inter-Instrument Agreement XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃)
Illuminants A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84
Display Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency
Color Spaces L*a*b, L*C*h, Hunter Lab, Yxy, XYZ
Color Difference ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort
Other Indices WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength
Other Functions 1. Camera to view measurement area 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement) 3. Auto humidity and temperature compensation function
Illumination/ Viewing System Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing )
Interface USB USB-B RS-232
Screen Size 7 Inches Touch Screen
Storage Memory 8 GB U Disk for data storage and transfer
Power 12V/3A
Dimensions (L × W × H) 430 × 240 × 260 mm
Weight 10.8 kg
Table top spectrophotometer LTS-A10
Illumination system d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range 400-700 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Observation Angle 2°/10°
Measurement caliber
Measurement time interval 0.5 s
Measurement time 1 s
Measuring aperture 11 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK
Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73) Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density
Repeatability light splitting reflectivity:standard deviation within 0.08% color values:ΔE*ab
Color matching system Matches
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Battery capacity Rechargeable, 20000 continuous tests, 7.4V/6000mAh
Data being displayed SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB
Display 5.5 inch TFT touch screen
Data storage 20000 test results
Light source longevity 10 years, 3 million tests
Dimension (L*W*H) 350 × 300 × 200 mm
Weight 4.5 kg
Table top spectrophotometer LTS-A11
Illumination system d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range 400-700 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Observation Angle 2°/10°
Measurement caliber
Measurement time interval 0.5 s
Measurement time 1 s
Measuring aperture 11 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK
Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73) Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density
Repeatability light splitting reflectivity:standard deviation within 0.08% color values:ΔE*ab
Color matching system Matches
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Battery capacity Rechargeable, 20000 continuous tests, 7.4V/6000mAh
Data being displayed SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB
Display 5.5 inch TFT touch screen
Data storage 20000 test results
Light source longevity 10 years, 3 million tests
Dimension (L*W*H) 350 × 300 × 200 mm
Weight 4.5 kg

Portable Spectrophotometer

Portable Spectrophotometer LSP-A30

Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
Sensor High sensitivity silicon photodiode
Test angle -
Test area -
Test range -
Test repeatability -
Reproducibility -
Inter instrument agreement 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles)
Illumination light source LED
Light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35
Wavelength range 400 nm to 700 nm
Wavelength interval 10 nm
Observation angle 2°/10°
Measuring aperture 11 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK
Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density.
Color matching system Not included
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Battery capacity Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh
Interface USB
Data storage 20000 samples
Display True color TFT touch screen
Light source longevity 10 years, 3 million test
Dimension 181 × 73 × 112 mm
Weight 800 g (without battery)

Portable Spectrophotometer LSP-A31

Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
Sensor High sensitivity silicon photodiode
Test angle 60°
Test area 5 × 10 mm
Test range 0 to 1000 GU
Test repeatability 0.2 GU (0 to 100 GU), 0.2% (100 to 1000 GU)
Reproducibility 1.0 GU (0 to 100 GU), 1.0% (100 to 1000 GU)
Inter instrument agreement 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles)
Illumination light source LED
Light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35
Wavelength range 400 nm to 700 nm
Wavelength interval 10 nm
Observation angle 2°/10°
Measuring aperture 11 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK
Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density.
Color matching system Not included
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Battery capacity Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh
Interface USB
Data storage 20000 samples
Display True color TFT touch screen
Light source longevity 10 years, 3 million test
Dimension 181 × 73 × 112 mm
Weight 800 g (without battery)
Portable spectrophotometer LSP-A10
Illumination d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range 400-700 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Observation angle 2°/10°
Measurement time interval 2 seconds
Measurement time 2 seconds
Measuring aperture 8 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance
Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness
Color matching system Not match
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Battery capacity Rechargeable, 10000 continuous tests, 7.4V/6000 mAh
Data being displayed SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB
Data storage 100 test samples , 200 measurement records for each sample
Display True color TFT touch screen
Light source longevity 5 years, 1.5 million tests
Dimension (L*W*H) 181 × 73 × 112 mm
Weight 550 g
Portable spectrophotometer LSP-A11
Illumination d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
Sensor Dual light path sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range 400-700 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Observation angle 2°/10°
Measurement time interval 0.5 seconds
Measurement time 2 seconds
Measuring aperture 8 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB
Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz), Metamerism index Milm, adhesive/changing Color fastness, ISO illuminance, 8 gloss
Color matching system Matches
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Battery capacity Rechargeable, 20000 continuous tests, 7.4V/6000 mAh
Data being displayed SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB, Bluetooth
Data storage 100 test samples , 200 measurement records for each sample
Display True color TFT touch screen
Light source longevity 10 years, 3 million tests
Dimension (L*W*H) 181 × 73 × 112 mm
Weight 550 g

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A10

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Emission slit 2 nm, 5 nm, 10 nm, 20 nm
Wavelength accuracy ±0.4 nm
Wavelength repeatability ≤ 0.2 nm
Signal-to-Noise Ratio Raman peak of water (P-P): S/N ≥ 200 (10 nm Slit)
Detection limit ≤5×10-11 g/ml (Quinine Sulphate Solution)
Linearity γ ≥ 0.995
Peak repeatability ≤ 1.5%
Stability (10 min) Zero Drift ±0.3
Stability (10 min) Value Limit ±1.5%
Wavelength scan speed Multi-speed level, Maximum at 48000 nm/min
Photometric value 0.00 to 10000.00
Data interface USB 2.0
Maximum power consumption 200 W
Power Source AC 220 V/50 Hz; 110 V/60 Hz
Dimension 380×445×310 mm
Net weight 12 kg
Gross weight 14 kg

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Emission slit 2 nm, 5 nm, 10 nm, 20 nm
Wavelength accuracy ±1.0 nm
Wavelength repeatability ≤ 0.5 nm
Signal-to-Noise Ratio Raman peak of water (P-P): S/N ≥ 150 (10 nm Slit)
Detection limit ≤1×10-10 g/ml (Quinine Sulphate Solution)
Linearity γ ≥ 0.995
Peak repeatability ≤ 1.5%
Stability (10 min) Zero Drift ±0.3
Stability (10 min) Value Limit ±1.5%
Wavelength scan speed Multi-speed level, Maximum at 48000 nm/min
Photometric value 0.00 to 10000.00
Data interface USB 2.0
Maximum power consumption 200 W
Power Source AC 220 V/50 Hz; 110 V/60 Hz
Dimension 380×445×310 mm
Net weight 12 kg
Gross weight 14 kg
Fluorescence Spectrophotometer LFS-A11
Excitation Source 150 W Xenon Lamp
Excitation Wavelength 200 nm to 900 nm
Excitation Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Wavelength Accuracy ± 0.4 nm
Wavelength Repeatability ≤ 0.2 nm
Signal-to-Noise Ratio S/N ≥ 350 (P-P), S/N ≥ 1000 (RMS)
Limit ≤ 5 × 10 -11 g /ml(Quinine Sulfate Solution)
Linearity γ ≥ 0.995
Peak Repeatability ≤ 1.5 %
Wavelength Scan Speed Multi-speed Level, Maximum at 60000 nm / min
Minimum sample size 0.5 mL (Using a standard 10 mm square sample cell)
Octave filter Build in Octave filter
Photometric Quantity Range -9999 to 9999
Response Time Auto adjust (0.02 s, 0.1 s, 0.5 s, 1 s, 2 s, 4 s, 8 s )
Data Transportation USB 2.0
Power 200 W
Power Supply AC 220 V / 50 Hz, 110 V / 60 Hz
Dimension 610×460×365 mm
Net Weight 21 kg
Gross Weight 26 kg

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer LXLS-A10

Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Photometric Accuracy 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A)
Photometric Repeatability ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F)
Stray Light ≤ 0.03 % T @ 22 nm, 360 nm
Stability ± 0.0005 A/h @500 nm
Baseline Flatness ± 0.002 A
Noise 0.0005 A @ 500 nm
Work Mode T, A, C, E
Scanning Speed High, Medium, Low ( Max 3000 nm/ min )
Wavelength Setting Auto
Display 7 inch TFT Coloured Capacitive Touch Screen
Light Source Imported Xenon Lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10 mm single hole cell holder
Output USB Drive, USB host, RS232
Power Supply AC 220 V/ 500 Hz or AC 110 V / 60 Hz
Packaging dimension 810 × 660 × 390 mm
Gross Weight 27 kg

Xenon Lamp Spectrophotometer LXLS-A11

Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Photometric Accuracy 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A)
Photometric Repeatability ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F)
Stray Light ≤ 0.03 % T @ 22 nm, 360 nm
Stability ± 0.0005 A/h @500 nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A @ 500 nm
Work Mode T, A, C, E
Scanning Speed High, Medium, Low ( Max 3000 nm/ min )
Wavelength Setting Auto
Display 7 inch TFT Coloured Capacitive Touch Screen
Light Source Imported Xenon Lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10 mm single hole cell holder
Output USB Drive, USB host, RS232
Power Supply AC 220 V/ 500 Hz or AC 110 V / 60 Hz
Packaging dimension 810 × 660 × 390 mm
Gross Weight 27 kg
Xenon Lamp Spectrophotometer LXLS-A13
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Photometric Accuracy 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A)
Photometric Repeatability ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F)
Stray Light ≤ 0.03 % T @ 22 nm, 360 nm
Stability ± 0.0003 A/h @500 nm
Baseline Flatness ± 0.002 A
Noise 0.0005 A @ 500 nm
Work Mode T, A, C, E
Scanning Speed High, Medium, Low ( Max 3000 nm/ min )
Wavelength Setting Auto
Display 10.1inch TFT Coloured Capacitive Touch Screen
Light Source Imported Xenon Lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10 mm single hole cell holder
Output USB Drive, USB host, RS232
Power Supply AC 220 V/ 500 Hz or AC 110 V / 60 Hz
Packaging dimension 810 × 660 × 390 mm
Gross Weight 27 kg
Xenon Lamp Spectrophotometer LXLS-A14
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Photometric Accuracy 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A)
Photometric Repeatability ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F)
Stray Light ≤ 0.03 % T @ 22 nm, 360 nm
Stability ± 0.0003 A/h @500 nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A @ 500 nm
Work Mode T, A, C, E
Scanning Speed High, Medium, Low ( Max 3000 nm/ min )
Wavelength Setting Auto
Display 10.1inch TFT Coloured Capacitive Touch Screen
Light Source Imported Xenon Lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10 mm single hole cell holder
Output USB Drive, USB host, RS2
Power Supply AC 220 V/ 500 Hz or AC 110 V / 60 Hz
Packaging dimension 810 × 660 × 390 mm
Gross Weight 27 kg