We manufacture range of potable to benchtop Water Testing Equipment that are widely used by laboratories to check various parameter related to water quality like salinity, turbidity, BOD, etc.
Measuring range (NTU) : | 0 to 100, 0 to 200 |
Minimum readout value (NTU) : | 0.01 |
Calibration point : | 2 |
Sample volume : | 18 to 20 ml |
Measuring range (NTU) : | 0 to 100, 0 to 200, 0 to 500 |
Minimum readout value (NTU) : | 0.01 |
Calibration point : | 3 |
Sample volume : | 18 to 20 ml |
Measuring range (NTU) : | 0 to 10, 0 to 100, 0 to 200, 0 to 500 |
Minimum readout value (NTU) : | 0.001 |
Calibration point : | 4 |
Sample volume : | 18 to 20 ml |
Measuring range (NTU) : | 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000 |
Minimum readout value (NTU) : | 0.01 |
Calibration point : | 5 |
Sample volume : | 18 to 20 ml |
Measuring range (NTU) : | 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000 |
Minimum readout value (NTU) : | 0.001 |
Calibration point : | 5 |
Sample volume : | 18 to 20 ml |
Measuring range (NTU) : | 0 to 10, 0 to 100 |
Minimum readout value (NTU) : | 0.001 |
Calibration point : | 2 |
Sample volume : | 18 to 20 ml |
Measuring range (NTU) : | 0 to 100 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 1 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 50, 0 to 100, 0 to 200 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 3 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 50, 0 to 100, 0 to 200, 0 to 400 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 4 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 5 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 6 |
Sample volume : | 5 to 10 ml |
Conductivity measurement range : | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy : | ± 1 % F.S. |
Conductivity resolution : | 0.01, 0.1, 1 |
Conductivity calibration solutions : | 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm |
Conductivity measurement range : | 0.000 μS/cm to 3000mS/cm |
Resistivity measurement range : | 5.00 Ω·cm to 100.0 MΩ·cm |
TDS measurement range : | 0.000 mg/L to 1000g/L |
Salinity measurement range : | 0.00 to 8.00 % |
Conductivity Mode : |
| ||||||||||||
TDS Mode : |
| ||||||||||||
Temperature Mode : |
| ||||||||||||
Cell constant : | K=0.1, 1, 10 |
Dissolved oxygen range : | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy : | ± 0.5 mg / L |
Resolution : | 0.1 mg / L |
Calibration points : | 1 - 2 points |
Dissolved oxygen range : | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy : | ± 0.2 mg / L |
Resolution : | 0.01 mg / L |
Calibration points : | 1 - 2 points |
Ion measurement range : | K range: 1×106 - 1M, 0.04 -39000 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm |
Ion measurement accuracy : | ± 0.5 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm |
Ion measurement accuracy : | ± 0.5 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Cd range: 1×106– 1M, 0.01-11200 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm |
Ion measurement accuracy : | ± 0.5 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Cu range: 1×108 - 1M, 0.06-6400 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | F range: 1 × 106M – saturation, 0.02 ppm to saturation |
Ion measurement accuracy : | ± 0.5 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | I range: 1×108- 1M, 0.06 -127000 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm |
Ion measurement accuracy : | ± 0.5 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm |
Ion measurement accuracy : | ± 0.5 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | Pb range: 1×108 – 0.1M, 0.2-20700 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
Ion measurement range : | S range: 1×107 - 1M, 0.003-32100 ppm |
Ion measurement accuracy : | ± 1 % F.S. |
Resolution : | 0.001, 0.01, 0.1, 1 |
Calibration points : | 2 to 5 points |
pH Mode : |
| ||||||||||||||||||
mV Mode : |
| ||||||||||||||||||
Conductivity Mode : |
| ||||||||||||||||||
TDS Mode : |
|
pH Mode : |
| ||||||||||||||||||
mV Mode : |
| ||||||||||||||||||
Conductivity Mode : |
| ||||||||||||||||||
TDS Mode : |
|
pH Mode : |
| ||||||||||||||||||
mV Mode : |
| ||||||||||||||||||
Conductivity Mode : |
| ||||||||||||||||||
Dissolved Oxygen Mode : |
|
pH Mode : |
| ||||||||||||
ORP Mode : |
| ||||||||||||
Ion Mode : |
| ||||||||||||
Water Hardness Mode : |
|
pH measurement range : | 0.00 to 14.00 pH |
pH accuracy : | ± 0.01 pH |
pH resolution : | 0.01 pH |
Calibration points : | 2 points |
pH measurement range : | -1.00 to 15.00 pH |
pH accuracy : | ± 0.01 pH |
pH resolution : | 0.01 pH |
Calibration points : | 1-3 points |
pH measurement range : | -2.000 to 20.000 pH |
pH accuracy : | ± 0.002 pH |
Calibration points : | 1-5 points |
Calibration solutions : | USA, NIST, DIN or user defined |
Temperature compensation : | 0 to 100°C, 32°F to 212°F Manual or Automatic |
Hold function : | Manual or automatic endpoint detection |
Stability criteria : | Standard or High-accuracy |
Interval readings : | 10, 30, 60 seconds, 10, 30 minutes or Off |
Water hardness range : | 0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy : | ± 1 % F.S. |
Calibration points : | 2 to 5 points |
Calibration solution : | 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L |
Determination range : |
| ||
Measurement error : | Less or less than 10 % | ||
Sample container/ bottle quantity : | 1 to 6 | ||
Sample container/ bottle Capacity : | 1000 ml |
COD : |
| ||||||||||||||||||||||
Ammonia nitrogen : |
| ||||||||||||||||||||||
Total phosphorous : |
| ||||||||||||||||||||||
Turbidity : |
|
COD : |
| ||||||||||||||||||||||
Ammonia nitrogen : |
| ||||||||||||||||||||||
Total phosphorous : |
| ||||||||||||||||||||||
Turbidity : |
|
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Different electrodes can be connceted via BNC Connector |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
TDS range : | 0 - 20 ppt |
TDS accuracy : | ± 1 % F.S. |
TDS factor : | 0.1 to 1.0 (default 0.5) |
Calibration points : | 1 - 3 points |
Conductivity measurement range : | 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm |
Conductivity calibration points : | 1 to 3 points |
Conductivity accuracy : | ±1 % F.S. |
Conductivity resolution : | 0.001/ 0.01/ 0.1/ 1 |
Dissolved oxygen range : | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen Calibration points : | 1 - 2 points |
Dissolved oxygen accuracy : | ± 0.5 mg / L |
Dissolved oxygen resolution : | 0.1 mg / L |
pH measurement range : | 01.00 to 15.00 pH |
pH calibration points : | 1 to 3 points |
pH Buffer Solutions : | USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18) |
pH accuracy : | ± 0.01 pH |
Conductivity measurement range : | 1.0 to 199.9 µS/cm |
Type of conductivity : | Low range conductivity |
Conductivity accuracy : | ± 1 % F.S. |
Conductivity calibration points : | 1 point |
Conductivity measurement range : | 10 to 1999 µS/cm |
Type of conductivity : | Mid-range conductivity |
Conductivity accuracy : | ± 1 % F.S. |
Conductivity calibration points : | 1 point |
Conductivity measurement range : | 0.1 to 19.99 mS/cm |
Type of conductivity : | High range conductivity |
Conductivity accuracy : | ± 1 % F.S. |
Conductivity calibration points : | 1 point |
Dissolved oxygen range : | 0.0 to 20.0 mg/L (or ppm) |
Dissolved oxygen accuracy : | ± 0.5 mg/L |
% of saturation of oxygen : | 0.0 to 200.0% |
Sensor type : | Polarographic dissolved oxygen probe |
Sensor type : | Platinum sensor |
Connector : | 6 pin |
ORP measurement range : | (-999) to 999 mV |
ORP accuracy : | ± 2 mV |
Connector : | BNC |
ORP measurement range : | (-999) to 999 mV |
ORP accuracy : | ± 2 mV |
ORP resolution : | 1 mV |
pH measurement range : | 0.0 - 14.00 pH |
Shape of electrode : | Round glass pH electrode |
pH measurement accuracy : | ± 0.1 pH |
Calibration point : | 2 points |
pH measurement range : | 0.0 - 14.00 pH |
Shape of electrode : | Flat pH electrode |
pH measurement accuracy : | ± 0.1 pH |
Calibration point : | 2 points |
pH measurement range : | 0.0 - 14.00 pH |
Shape of electrode : | Long distance planar pH electrode |
pH measurement accuracy : | ± 0.1 pH |
Calibration point : | 2 points |
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Round glass pH electrode |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Flat pH electrode |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Long distance planar pH electrode |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Round glass pH electrode |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Flat pH electrode |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
pH measurement range : | pH range: (-1.00) to 15.00 pH |
Shape of electrode : | Long distance planar pH electrode |
pH measurement accuracy : | ± 0.01 pH |
Calibration point : | 1 - 3 points |
Salinity measurement range : | 0.00 to 10.00 ppt |
Salinity accuracy : | ± 1 % F.S |
Conductivity range : | 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm |
Calibration solutions : | 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
Salinity measurement range : | 0.00 to 80.00 ppt |
Salinity accuracy : | ± 1 % F.S |
Conductivity range : | 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm |
Calibration solutions : | 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
TDS range : | 0.5 - 100.0 ppm |
TDS accuracy : | ± 1 % F.S. |
TDS factor : | 0.4 to 1.0 (default 0.5) |
Calibration points : | 1 point |
TDS range : | 5 - 1000 ppm |
TDS accuracy : | ± 1 % F.S. |
TDS factor : | 0.4 to 1.0 (default 0.5) |
Calibration points : | 1 point |
TDS range : | 0.05 - 10.00 ppt |
TDS accuracy : | ± 1 % F.S. |
TDS factor : | 0.4 to 1.0 (default 0.5) |
Calibration points : | 1 point |
Residual chlorine/total chlorine : |
| ||||||||
Chlorine dioxide : |
| ||||||||
Light source : | LED | ||||||||
Wavelength of light : | 515 nm |
Conductivity : |
| ||||||||||
Temperature : |
| ||||||||||
Temperature compensation : | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient : | Linear |
Conductivity : |
| ||||||||||
TDS : |
| ||||||||||
Temperature : |
| ||||||||||
Temperature compensation : | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Conductivity : |
| ||||||||||
Salinity : |
| ||||||||||
Temperature : |
| ||||||||||
Temperature compensation : | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Conductivity : |
| ||||||||||
TDS : |
| ||||||||||
Salinity : |
| ||||||||||
Resistivity : |
|
Dissolved oxygen range : | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy : | ± 0.5 mg / L |
Resolution : | 0.1 mg / L |
Calibration points : | 1 - 2 points |
Dissolved oxygen range : | 0.0 - 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy : | ± 0.2 mg / L |
Resolution : | 0.01 mg / L |
Calibration points : | 1 - 2 points |
pH mode : |
| ||||||||||||||||
ORP measurement : |
| ||||||||||||||||
Ion measurement : |
| ||||||||||||||||
Conductivity measurement : |
|
pH mode : |
| ||||||||||||||||
ORP measurement : |
| ||||||||||||||||
Ion measurement : |
| ||||||||||||||||
Conductivity measurement : |
|
pH mode : |
| ||||||||||||||||
ORP measurement : |
| ||||||||||||||||
Conductivity measurement : |
| ||||||||||||||||
TDS measurement : |
|
pH mode : |
| ||||||||||||||
ORP measurement : |
| ||||||||||||||
Dissolved oxygen : |
| ||||||||||||||
Temperature compensation : | 0 to 100 °C, 32 to 212 °F, Manual or Automatic |
pH range : | (-2.00) to 16.00 pH |
pH accuracy : | ± 0.01 pH |
pH resolution : | 0.01 pH |
Calibration points : | 2 points |
pH range : | (-2.00) to 20.00 pH |
pH accuracy : | ± 0.002 pH |
pH resolution : | 0.1, 0.01, 0.001 pH |
Calibration points : | 1 - 5 points |
Measuring range (NTU) : | 0 to 200 |
Minimum readout value (NTU) : | 0.1 |
Calibration point : | Nil |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 100, 0 to 200 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 4 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 100, 100 to 400 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 5 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 100, 100 to 500 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 6 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 100, 100 to 800 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 6 |
Sample volume : | 5 to 10 ml |
Measuring range (NTU) : | 0 to 100, 100 to 1000 |
Minimum readout value (NTU) : | 0.01, 0.1 |
Calibration point : | 7 |
Sample volume : | 5 to 10 ml |
Light source : | LED/860 nm (Wavelength) |
Readings display : | LCD |
Unit switches : | NTU, FTU, EBC, ASBC |
Measurement range : | 0.00-20.0; 20.01-200; 200.01-1000 NTU |
Water hardness range : | 0.05 mmol / L - 0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy : | ± 1 % F.S. |
Calibration points : | 2 to 5 points |
Calibration solution : | 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L |
Measurement range : | 20000 mg/L 0.01 mg/L ~ 45000 mg/L 0.01 mg/L ~ 120000 mg/L |
Measurement accuracy : | ± 2 % F.S. of its range ( Depending on the homogeneity of sludge) |
Pressure range : | ≤ 0.4 Mpa |
Flow rate : | ≤ 2.5 m/s, 8.2 ft./s |
Range : | 0 to 1.0 aw |
Resolution : | 0 to 1.0 aw |
Accuracy : | ± 0.02 aw |
Sensor : | Nonconductive humidity sensor |
Measuring range : | Water activity 0 to 0.980 aw (no condensing ) |
Temperature range : | 0 to 50°C |
Measurement accuracy : | ± 0.015 aw |
Temperature accuracy : | ± 0.5°C |