Need Help ?

Water Testing

We manufacture range of potable to benchtop Water Testing Equipment that are widely used by laboratories to check various parameter related to water quality like salinity, turbidity, BOD, etc.

Bench top Turbidity Meter (with built-in printer) LTM-C10
Measuring range (NTU) : 0 to 100, 0 to 200
Minimum readout value (NTU) : 0.01
Calibration point : 2
Sample volume : 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C11
Measuring range (NTU) : 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) : 0.01
Calibration point : 3
Sample volume : 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C12
Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) : 0.001
Calibration point : 4
Sample volume : 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C13
Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) : 0.01
Calibration point : 5
Sample volume : 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C14
Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) : 0.001
Calibration point : 5
Sample volume : 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C15
Measuring range (NTU) : 0 to 10, 0 to 100
Minimum readout value (NTU) : 0.001
Calibration point : 2
Sample volume : 18 to 20 ml
Bench top Turbidity Meter LTM-B10
Measuring range (NTU) : 0 to 100
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 1
Sample volume : 5 to 10 ml
Bench top Turbidity Meter LTM-B11
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 3
Sample volume : 5 to 10 ml
Bench top Turbidity Meter LTM-B12
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 4
Sample volume : 5 to 10 ml
Bench top Turbidity Meter LTM-B13
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 5
Sample volume : 5 to 10 ml
Bench top Turbidity Meter LTM-B14
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 6
Sample volume : 5 to 10 ml
Benchtop conductivity meter LBCM-A11
Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy : ± 1 % F.S.
Conductivity resolution : 0.01, 0.1, 1
Conductivity calibration solutions : 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Benchtop Conductivity Meter LBCM-A13
Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
Resistivity measurement range : 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range : 0.000 mg/L to 1000g/L
Salinity measurement range : 0.00 to 8.00 %
Benchtop Conductivity Meter LBCM-A14
Conductivity Mode :
Conductivity measurement range 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity accuracy ±1% F.S.
Conductivity resolution 0.001, 0.01, 0.1, 1
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode :
TDS measurement Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.01 to 1.00 (default 0.5)
TDS Calibration points 3 points
Temperature Mode :
Temperature range 0 to 105°C, 32 to 221°F
Temperature accuracy ±1°C
Temperature resolution 0.1°C, 0.1°F
Temperature calibration points 1 point
Temperature Compensation Range and Mode Manual or Automatic, 0 to 100°C , 32 to 212°F
Temperature coefficient 0.0 to 10.0 % per °C
Cell constant : K=0.1, 1, 10
Benchtop Dissolved oxygen meter LBDO-A10
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.5 mg / L
Resolution : 0.1 mg / L
Calibration points : 1 - 2 points
Benchtop Dissolved oxygen meter LBDO-A11
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.2 mg / L
Resolution : 0.01 mg / L
Calibration points : 1 - 2 points
Benchtop Ion meter for K, LBIM-A23
Ion measurement range : K range: 1×106 - 1M, 0.04 -39000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Ag, LBIM-A22
Ion measurement range : Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Br, LBIM-A14
Ion measurement range : Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Ca, LBIM-A13
Ion measurement range : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Cd, LBIM-A28
Ion measurement range : Cd range: 1×106– 1M, 0.01-11200 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Cl, LBIM-A10
Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Cn, LBIM-A21
Ion measurement range : Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Cu, LBIM-A27
Ion measurement range : Cu range: 1×108 - 1M, 0.06-6400 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for F, LBIM-A11
Ion measurement range : F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for I, LBIM-A26
Ion measurement range : I range: 1×108- 1M, 0.06 -127000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Na, LBIM-A12
Ion measurement range : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for NH3 , LBIM-A20
Ion measurement range : NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for NH4, LBIM-A15
Ion measurement range : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for Pb, LBIM-A25
Ion measurement range : Pb range: 1×108 – 0.1M, 0.2-20700 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Ion meter for S, LBIM-A24
Ion measurement range : S range: 1×107 - 1M, 0.003-32100 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
pH Mode :
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode :
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode :
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode :
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
pH Mode :
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode :
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode :
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode :
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
Benchtop Multi-parameter Water Quality Meter LMPWM-A32
pH Mode :
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode :
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode :
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
Dissolved Oxygen Mode :
Dissolved Oxygen Range 0.00 to 20.00 mg/ L
Dissolved Oxygen Accuracy ± 0.2 mg/ L
Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
Dissolved Oxygen Calibration Points 1 or 2 Points
% Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 to 50 g/ L
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
pH Mode :
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
ORP Mode :
mV Range ± 2000 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV, selectable
mV Calibration Points 1 Point, only for relative mode
Ion Mode :
Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection)
Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Ion measurement resolution 0.001/0.01/0.1/1
Ion measurement calibration points 2 to 5 points
Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L
Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction
Water Hardness Mode :
Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3)
Water hardness measurement accuracy ±1% F.S
Water hardness measurement resolution 0.001/0.01/0.1/1
Water hardness calibration points 2 to 5 points
Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L
Benchtop pH meter LBPM-A11
pH measurement range : 0.00 to 14.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Calibration points : 2 points
Benchtop pH meter LBPM-A20
pH measurement range : -1.00 to 15.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Calibration points : 1-3 points
Benchtop pH meter LBPM-B10
pH measurement range : -2.000 to 20.000 pH
pH accuracy : ± 0.002 pH
Calibration points : 1-5 points
Calibration solutions : USA, NIST, DIN or user defined
Benchtop pH Meter LBPM-B11
Temperature compensation : 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function : Manual or automatic endpoint detection
Stability criteria : Standard or High-accuracy
Interval readings : 10, 30, 60 seconds, 10, 30 minutes or Off
Benchtop Water hardness meter LBWM-A10
Water hardness range : 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy : ± 1 % F.S.
Calibration points : 2 to 5 points
Calibration solution : 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
BOD Meter LBOD-A10
Determination range :
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error : Less or less than 10 %
Sample container/ bottle quantity : 1 to 6
Sample container/ bottle Capacity : 1000 ml
Multi parameter water quality analyzer LMWA-A10
COD :
COD determination range 2 to 10000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen :
Ammonia nitrogen determination range 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous :
Total phosphorous determination range 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity :
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette
Multi parameter water quality analyzer LMWA-A11
COD :
COD determination range 5 to 5000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen :
Ammonia nitrogen determination range 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch 20 pcs
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous :
Total phosphorous determination range 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity :
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette
Multi purpose Pocket pH tester LPPT-B10
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Different electrodes can be connceted via BNC Connector
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Multi-range pocket TDS tester LPTS-A20
TDS range : 0 - 20 ppt
TDS accuracy : ± 1 % F.S.
TDS factor : 0.1 to 1.0 (default 0.5)
Calibration points : 1 - 3 points
Online Conductivity Controller LOCC-A10
Conductivity measurement range : 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm
Conductivity calibration points : 1 to 3 points
Conductivity accuracy : ±1 % F.S.
Conductivity resolution : 0.001/ 0.01/ 0.1/ 1
Online Dissolved Oxygen Controller LODC-A10
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen Calibration points : 1 - 2 points
Dissolved oxygen accuracy : ± 0.5 mg / L
Dissolved oxygen resolution : 0.1 mg / L
Online pH Controller LOPC-A10
pH measurement range : 01.00 to 15.00 pH
pH calibration points : 1 to 3 points
pH Buffer Solutions : USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy : ± 0.01 pH
Pocket Conductivity tester LPCT-A10
Conductivity measurement range : 1.0 to 199.9 µS/cm
Type of conductivity : Low range conductivity
Conductivity accuracy : ± 1 % F.S.
Conductivity calibration points : 1 point
Pocket Conductivity tester LPCT-A11
Conductivity measurement range : 10 to 1999 µS/cm
Type of conductivity : Mid-range conductivity
Conductivity accuracy : ± 1 % F.S.
Conductivity calibration points : 1 point
Pocket Conductivity tester LPCT-A12
Conductivity measurement range : 0.1 to 19.99 mS/cm
Type of conductivity : High range conductivity
Conductivity accuracy : ± 1 % F.S.
Conductivity calibration points : 1 point
Pocket Dissolved oxygen tester LPKDO-A10
Dissolved oxygen range : 0.0 to 20.0 mg/L (or ppm)
Dissolved oxygen accuracy : ± 0.5 mg/L
% of saturation of oxygen : 0.0 to 200.0%
Sensor type : Polarographic dissolved oxygen probe
Pocket ORP tester LPOT-A10
Sensor type : Platinum sensor
Connector : 6 pin
ORP measurement range : (-999) to 999 mV
ORP accuracy : ± 2 mV
Pocket ORP tester LPOT-A11
Connector : BNC
ORP measurement range : (-999) to 999 mV
ORP accuracy : ± 2 mV
ORP resolution : 1 mV
Pocket pH tester LPPT-A10
pH measurement range : 0.0 - 14.00 pH
Shape of electrode : Round glass pH electrode
pH measurement accuracy : ± 0.1 pH
Calibration point : 2 points
Pocket pH tester LPPT-A11
pH measurement range : 0.0 - 14.00 pH
Shape of electrode : Flat pH electrode
pH measurement accuracy : ± 0.1 pH
Calibration point : 2 points
Pocket pH tester LPPT-A12
pH measurement range : 0.0 - 14.00 pH
Shape of electrode : Long distance planar pH electrode
pH measurement accuracy : ± 0.1 pH
Calibration point : 2 points
Pocket pH tester LPPT-A20
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Round glass pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Pocket pH tester LPPT-A21
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Flat pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Pocket pH tester LPPT-A22
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Long distance planar pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Pocket pH tester LPPT-A30
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Round glass pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Pocket pH tester LPPT-A31
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Flat pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Pocket pH tester LPPT-A32
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Long distance planar pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Pocket Salinity tester LPST-A10
Salinity measurement range : 0.00 to 10.00 ppt
Salinity accuracy : ± 1 % F.S
Conductivity range : 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Calibration solutions : 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Pocket Salinity tester LPST-A11
Salinity measurement range : 0.00 to 80.00 ppt
Salinity accuracy : ± 1 % F.S
Conductivity range : 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
Calibration solutions : 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
Pocket TDS tester LPTS-A10
TDS range : 0.5 - 100.0 ppm
TDS accuracy : ± 1 % F.S.
TDS factor : 0.4 to 1.0 (default 0.5)
Calibration points : 1 point
Pocket TDS tester LPTS-A11
TDS range : 5 - 1000 ppm
TDS accuracy : ± 1 % F.S.
TDS factor : 0.4 to 1.0 (default 0.5)
Calibration points : 1 point
Pocket TDS tester LPTS-A12
TDS range : 0.05 - 10.00 ppt
TDS accuracy : ± 1 % F.S.
TDS factor : 0.4 to 1.0 (default 0.5)
Calibration points : 1 point
Portable Chlorine Meter LPCL-A10
Residual chlorine/total chlorine :
Range 0.00 to 5.00 mg/L
Accuracy 0.001 mg/L 0.001 ABS
Repeatability Lower detection limit ≤0.02 mg/L
Chlorine dioxide :
Range 0.00 to 10.00 mg/L
Resolution 0.001 mg/L 0.001 ABS
Accuracy ≤2 mg/L: ±0.10 mg/L ˃2 mg/L: ±5 %
Lower detection limit ≤0.04 mg/L
Light source : LED
Wavelength of light : 515 nm
Portable Conductivity Meter LPCM-A10
Conductivity :
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Temperature :
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient : Linear
Portable Conductivity Meter LPCM-A11
Conductivity :
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
TDS :
TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS accuracy ±1 % F.S
TDS factor 0.01 to 1.00 (Default 0.5)
TDS resolution 0.01, 0.1, 1
Temperature :
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A12
Conductivity :
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Salinity :
Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
Salinity accuracy ±1% F.S
Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
Salinity resolution 0.01, 0.1, 1
Temperature :
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A13
Conductivity :
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
TDS :
TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS accuracy ±1 % F.S
TDS factor 0.01 to 1.00 (Default 0.5)
TDS resolution 0.01, 0.1, 1
Salinity :
Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
Salinity accuracy ±1% F.S
Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
Salinity resolution 0.01, 0.1, 1
Resistivity :
Resistivity range 0.00 to 20 MΩ
Resistivity accuracy ±1% F.S
Resistivity resolution 0.01, 0.1, 1
Portable Dissolved oxygen meter LPRDO-A10
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.5 mg / L
Resolution : 0.1 mg / L
Calibration points : 1 - 2 points
Portable dissolved oxygen meter LPRDO-A11
Dissolved oxygen range : 0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.2 mg / L
Resolution : 0.01 mg / L
Calibration points : 1 - 2 points
Portable Multi-parameter Water Quality Meter LMPWM-A10
pH mode :
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement :
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement :
Ion measurement range 0 to 19999 ppm, mg/L, mol/L
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points 2 - 5 points
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurement :
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
Portable Multi-parameter Water Quality Meter LMPWM-A11
pH mode :
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement :
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement :
Ion measurement range
Ion accuracy
Ion calibration points
Ion calibration solutions
Conductivity measurement :
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
Portable Multi-parameter Water Quality Meter LMPWM-A20
pH mode :
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement :
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Conductivity measurement :
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement :
TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
Portable Multi-parameter Water Quality Meter LMPWM-A21
pH mode :
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement :
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Dissolved oxygen :
DO concentration range 0.00 to 20.00 mg/L
DO accuracy ± 0.2 mg/L
Calibration points 1 - 2 points
Pressure correction 60.0 to 112.5 kPa, 450 - 850 mmHg
Salinity correction 0 to 50 g/L
% Saturation of Oxygen 0.0 to 200.0 %
Accuracy ± 2.0 %
Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Portable pH meter LPRPM-A10
pH range : (-2.00) to 16.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Calibration points : 2 points
Portable pH/ORP meter LPRPM-A11
pH range : (-2.00) to 20.00 pH
pH accuracy : ± 0.002 pH
pH resolution : 0.1, 0.01, 0.001 pH
Calibration points : 1 - 5 points
Portable Turbidity Meter LTM-A10
Measuring range (NTU) : 0 to 200
Minimum readout value (NTU) : 0.1
Calibration point : Nil
Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A11
Measuring range (NTU) : 0 to 100, 0 to 200
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 4
Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A12
Measuring range (NTU) : 0 to 100, 100 to 400
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 5
Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A13
Measuring range (NTU) : 0 to 100, 100 to 500
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 6
Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A14
Measuring range (NTU) : 0 to 100, 100 to 800
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 6
Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A15
Measuring range (NTU) : 0 to 100, 100 to 1000
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 7
Sample volume : 5 to 10 ml
Portable turbidity meter LTM-A16
Light source : LED/860 nm (Wavelength)
Readings display : LCD
Unit switches : NTU, FTU, EBC, ASBC
Measurement range : 0.00-20.0; 20.01-200; 200.01-1000 NTU
Portable water hardness meter LPWM-A10
Water hardness range : 0.05 mmol / L - 0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy : ± 1 % F.S.
Calibration points : 2 to 5 points
Calibration solution : 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L
TSS Meter LTSS-A10
Measurement range : 20000 mg/L
0.01 mg/L ~ 45000 mg/L
0.01 mg/L ~ 120000 mg/L
Measurement accuracy : ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)
Pressure range : ≤ 0.4 Mpa
Flow rate : ≤ 2.5 m/s, 8.2 ft./s
Water Activity Meter LWTM-A10
Range : 0 to 1.0 aw
Resolution : 0 to 1.0 aw
Accuracy : ± 0.02 aw
Sensor : Nonconductive humidity sensor
Water Activity Meter with sensor LWAM-A10
Measuring range : Water activity 0 to 0.980 aw (no condensing )
Temperature range : 0 to 50°C
Measurement accuracy : ± 0.015 aw
Temperature accuracy : ± 0.5°C