We manufacture CO2 incubators in both air jacketed and water jacketed type, those are widely used for a broad range of applications that includes tissue engineering, in vitro fertilization, neuroscience, cancer research, stem cell research, etc. Air jacketed incubators features outstanding temperature stability. Our water jacketed incubator is made up of corrosion resistant stainless steel and provides protection against over temperature and current leakage.
Chamber Volume : | 40 L |
Shelves : | 2 |
Heating Method : | Air-jacketed |
Temperature Range : | RT+5 ℃ to 50 ℃ |
Chamber Volume : | 80 L |
Shelves : | 2 |
Heating Method : | Air-jacketed |
Temperature Range : | RT+5 ℃ to 50 ℃ |
Chamber Volume : | 155 L |
Shelves : | 3 |
Heating Method : | Air-jacketed |
Temperature Range : | RT+5 ℃ to 50 ℃ |
Chamber Volume : | 233 L |
Shelves : | 3 |
Heating Method : | Air-jacketed |
Temperature Range : | RT+5 ℃ to 50 ℃ |
Chamber Volume : | 80 L |
Shelves : | 2 (pcs) |
Heating Method : | Air-jacketed, PID Control |
Temperature Range : | RT + 5 to 50°C |
Chamber Volume : | 155 L |
Shelves : | 3 (pcs) |
Heating Method : | Air-jacketed, PID Control |
Temperature Range : | RT + 5 to 50°C |
Chamber Volume : | 233 L |
Shelves : | 3 (pcs) |
Heating Method : | Air-jacketed, PID Control |
Temperature Range : | RT + 5 to 50°C |
Chamber Volume : | 49 L |
Shelves : | 2 (pcs) |
Heating Method : | Air-jacketed, PID Control |
Temperature Range : | RT + 5 to 50°C |
Chamber Volume : | 80 L |
Shelves : | 2 (pcs) |
Heating Method : | Air-jacketed, PID Control |
Temperature Range : | RT + 5 to 50°C |
Chamber Volume : | 150 L |
Shelves : | 2 (pcs) |
Heating Method : | Air-jacketed, PID Control |
Temperature Range : | RT + 5 to 50°C |
CO2 range : | 0-20% |
CO2 recovery time : | (Return to 5% after opening the door for 30 seconds) ≤3 mins |
CO2 control accuracy : | ±0.1% |
CO2 stability of 5%CO2 : | ±0.1% |
CO2 range : | 0-20% |
CO2 recover time : | (Return to 5% after opening the door for 30 seconds) ≤3 mins |
CO2 control accuracy : | ±0.1% |
CO2 stability of 5%CO2 : | ±0.1% |
Chamber Volume : | 101 L |
Temperature Range : | Ambient 5 °C to 60 °C |
Temperature Accuracy : | ± 0.2 at 37 °C |
CO2 Range : | 0 to 20 % |
Chamber Volume : | 150 L |
Temperature Range : | Ambient 5 °C to 60 °C |
Temperature Accuracy : | ± 0.2 at 37 °C |
CO2 Range : | 0 to 20 % |
Chamber Volume : | 324 L |
Temperature Range : | Ambient 5 °C to 60 °C |
Temperature Accuracy : | ± 0.2 at 37 °C |
CO2 Range : | 0 to 20 % |
Chamber Volume : | 49 L |
Temperature Range : | Ambient 5 °C to 60 °C |
Temperature Accuracy : | ± 0.2 at 37 °C |
CO2 Range : | 0 to 20 % |
Heating method : | Water Jacketed |
Chamber volume : | 170 L |
CO2 range : | 0 to 20 % |
CO2 control resolution : | ± 0.1% (IR Sensor) |
Chamber volume : | 240 L |
Heating method : | Water Jacketed |
CO2 control range : | 0 to 20% |
CO2 control accuracy : | ±0.1% (IR sensor) |