Air Jacketed CO2 Incubator LAJI-C11 offers outstanding temperature stability. Available with heat decontamination function and optional UV disinfection. Equipped with colored touch screen controller for displaying temperature, humidity, CO2 concentration. In forced convection mode unit and offers heating function which prevents condensation on outer door.
Specifications
Chamber Volume | 80 L |
Shelves | 2 |
Heating Method | Air-jacketed |
Temperature Range | RT+5 ℃ to 50 ℃ |
Temperature Resolution | 0.1 ℃ |
Temperature Fluctuation | 0.1 ℃ |
Temperature Gradient | ≤ ± 0.5 ℃ |
Temperature Uniformity | ± 0.3 ℃ |
CO2 Range | (0~20)% V/V |
CO2 Sensor | IR sensor |
CO2 Control Resolution | ± 0.1% |
CO2 Deviation | ≤ ±0.3%V/V |
Humidity Method | Natural vaporization > 95% |
Interior Dimension (W×H×D) | 400 × 500 × 450 mm |
Exterior Dimension (W×H×D) | 590 × 790 × 690 mm |
Electrical Requirement | AC220 V,50 Hz |
Power Consumption | 500 W |
Features
Air jacketed CO2 Incubator
Coloured touch screen displays temperature, humidity, CO2 concentration curves
ISO Class 5 chamber with air renewal system
Data logger with alarm features and dry contact alarm, humidity sensor with water top up alarm
Meets sterilisation of 99.99% with 80°C heat on cells
90℃ high temperature hot and humid sterilization system
In forced convection mode
Heating function preventing condensation on outer door
Independent temperature-limiting protection system
CO2 pressure-relief valve with 2-stage control and stable pressure
Optional HEPA filtration system
Applications
Air jacketed CO2 incubators are widely used for a broad range of applications that includes Tissue engineering, In vitro fertilization, Neuroscience, Cancer research, Stem cell research, Regenerative medicine, Mammalian cell research.
Optional Accessories
CO2 pressure releasing valve
RS485 connector
Request Quote
Heating method | Water Jacketed |
Chamber volume | 170 L |
CO2 range | 0 to 20 % |
CO2 control resolution | ± 0.1% (IR Sensor) |
CO2 recovery | (Door open 30 s, recovery to 5%) ≤ 3 min |
Temperature range | RT + 5 to 50°C |
Ambient temperature | 5 to 30°C |
Temperature stability | ± 0.1°C |
Temperature recovery | (Door open 30 s, recovery to 37℃ ) ≤ 8 min |
Humidity method | Natural vaporization > 95 % |
No. of shelves | 3 pcs |
Sterilization method | UV lamp sterilization |
Interior dimension | 530×460×720 mm |
Exterior dimension | 684×700×960 mm |
Power consumption | 700 W |
Power supply | AC 220 V, 50 Hz |
Packaging dimension | 820×810×1230 mm |
Packaging weight | 125 kg (1 CTN) |
Chamber Volume | 49 L |
Temperature Range | Ambient 5 °C to 60 °C |
Temperature Accuracy | ± 0.2 at 37 °C |
CO2 Range | 0 to 20 % |
CO2 Accuracy | ± 0.1 % at 37 °C |
Circulation | Natural Convection |
Sensor | Digital NDIR Sensor |
Device Safety | Over Temperature safety, Leakage breaker & Alarm Function |
Interior Dimension(W × D × H) | 350 x 360 x 405 mm |
Exterior Dimension(W × D × H) | 500 x 495 x 785 mm |
Power Supply | AC 220 V, 50 / 60 Hz |
Chamber Volume | 101 L |
Temperature Range | Ambient 5 °C to 60 °C |
Temperature Accuracy | ± 0.2 at 37 °C |
CO2 Range | 0 to 20 % |
CO2 Accuracy | ± 0.1 % at 37 °C |
Circulation | Natural Convection |
Sensor | Digital NDIR Sensor |
Device Safety | Over Temperature safety, Leakage breaker & Alarm Function |
Interior Dimension(W × D × H) | 450 x 450 x 500 mm |
Exterior Dimension(W × D × H) | 600 x 600 x 900 mm |
Power Supply | AC 220 V, 50 / 60 Hz |
Chamber Volume | 150 L |
Temperature Range | Ambient 5 °C to 60 °C |
Temperature Accuracy | ± 0.2 at 37 °C |
CO2 Range | 0 to 20 % |
CO2 Accuracy | ± 0.1 % at 37 °C |
Circulation | Natural Convection |
Sensor | Digital NDIR Sensor |
Device Safety | Over Temperature safety, Leakage breaker & Alarm Function |
Interior Dimension(W × D × H) | 495 x 515 x 600 mm |
Exterior Dimension(W × D × H) | 660 x 645 x 1010 mm |
Power Supply | AC 220 V, 50 / 60 Hz |
Chamber Volume | 40 L |
Shelves | 2 |
Heating Method | Air-jacketed |
Temperature Range | RT+5 ℃ to 50 ℃ |
Temperature Resolution | 0.1 ℃ |
Temperature Fluctuation | 0.1 ℃ |
Temperature Gradient | ≤ ± 0.5 ℃ |
Temperature Uniformity | ± 0.3 ℃ |
CO2 Range | (0~20)% V/V |
CO2 Sensor | IR sensor |
CO2 Control Resolution | ± 0.1% |
CO2 Deviation | ≤ ±0.3%V/V |
Humidity Method | Natural vaporization > 95% |
Interior Dimension (W×H×D) | 400 × 350 × 286 mm |
Exterior Dimension (W×H×D) | 590 × 576 × 440 mm |
Electrical Requirement | AC220 V,50 Hz |
Power Consumption | 400 W |
Chamber Volume | 155 L |
Shelves | 3 |
Heating Method | Air-jacketed |
Temperature Range | RT+5 ℃ to 50 ℃ |
Temperature Resolution | 0.1 ℃ |
Temperature Fluctuation | 0.1 ℃ |
Temperature Gradient | ≤ ± 0.5 ℃ |
Temperature Uniformity | ± 0.3 ℃ |
CO2 Range | (0~20)% V/V |
CO2 Sensor | IR sensor |
CO2 Control Resolution | ± 0.1% |
CO2 Deviation | ≤ ±0.3%V/V |
Humidity Method | Natural vaporization > 95% |
Interior Dimension (W×H×D) | 480 × 610 × 530 mm |
Exterior Dimension (W×H×D) | 670 × 880 × 770 mm |
Electrical Requirement | AC220 V,50 Hz |
Power Consumption | 650 W |
Chamber Volume | 233 L |
Shelves | 3 |
Heating Method | Air-jacketed |
Temperature Range | RT+5 ℃ to 50 ℃ |
Temperature Resolution | 0.1 ℃ |
Temperature Fluctuation | 0.1 ℃ |
Temperature Gradient | ≤ ± 0.5 ℃ |
Temperature Uniformity | ± 0.3 ℃ |
CO2 Range | (0~20)% V/V |
CO2 Sensor | IR sensor |
CO2 Control Resolution | ± 0.1% |
CO2 Deviation | ≤ ±0.3%V/V |
Humidity Method | Natural vaporization > 95% |
Interior Dimension (W×H×D) | 600×670×630 mm |
Exterior Dimension (W×H×D) | 790 × 940 × 840 mm |
Electrical Requirement | AC220 V,50 Hz |
Power Consumption | 950 W |
CO2 range | 0-20% |
CO2 recovery time | (Return to 5% after opening the door for 30 seconds) ≤3 mins |
CO2 control accuracy | ±0.1% |
CO2 stability of 5%CO2 | ±0.1% |
CO2 uniformity | ±0.1% |
CO2 sensor | IR CO2 sensor |
Shaking frequency | 40-300 rpm |
Shaking Precision | ±1 rpm |
Amplitude | 20 mm |
Drive way | Three eccentric shaft balance drive type |
Humidity control | 50 to 90% |
37C humidity control accuracy | The chamber can reach 85%-95% when 37˚ C , and the humidity can be controlled in real time |
Humidity resolution | 0.001 |
Humidity deviation | ±2% |
Related humidity | Nature vaporate > 95% |
Allowable shaking load | 10 kg |
Temperature control range | 4-65° C |
Temperature control accuracy | ±0.1° C |
Temperature uniformity | ±0.5° C |
Temperature sensor | PT 100 |
Environment temperature detector | Independent |
Over temperature protection system | Independent |
Temperature recover time | (Return to 37˚ C after opening the door for 30 sec) ≤8 mins |
Heating method | 6 side heating |
Disinfection method | 90˚ C high temp |
Timing range | 0 to 99 hour 59 min |
Platform size (L×B) | 350×350 mm |
Shelf | 1 |
Display | Digital Color display with touch panel |
Sterilization system | 90 degree high temp. high humidity sterilization system (RHP); UV sterilization (option) |
Controller | PID |
Interface | RS485 |
Door Open/close message | Yes |
Alarm system | High and low temperature and over temperature; Chamber sensor failure; Independent temperature limiter; Door open; High/low CO2 condensation; Power off alarm; Door temperature sensor failure; Disinfection and sterilization status reminder; Over temp sensor failure and Abnormal function |
Interior dimension (W×D×H) | 505×600×420 mm |
Exterior dimension (W×D×H) | 693×875×753 mm |
Gross Weight | 91 kg |
Power | 1500 W |
Voltage | 220V 50Hz |
Flask Configuration | 50 ml×36, 100 ml×23, 250 ml×13, 500 ml×8, 1 L×5, 2 L×3, 4 L×1, 5 L×1 |