Spectrometer

We manufacture different types of Spectrometers ranging from portable to benchtop model. they are widely used for monitoring dissolved oxygen content in freshwater and marine ecosystems, studying spectral emission lines of distant galaxies, characterization of proteins, respiratory gas analysis in hospitals, etc.

Angular Spectrometer LASM-A10
Angle Measurement Accuracy : 1inch
Optical Parameter :
Focal Length 170 mm
Effective Aperture Φ 22 mm
Field of View 3° 22inch
Focal Length of Telescope’s Eyepiece 24.3 mm
Maximum Length Between Collimator and Telescope 120 mm
Slit Width 0.02 to 2 mm
Diopter Compensation Range ≥ ± 5 diopters
Divided Circle :
Diameter Φ178 mm
Circle Graduation 0° to 360°
Division 0.5°
Vernier Reading Value 1inch
Stage :
Diameter Φ70 mm
Rotating Range 360°
Range of Vertical Adjustment 20 mm
Atomic Fluorescence Spectrometer LAFS-A10
Beam Configuration : Dual Channel
Elements ( Measuring Range ) :
As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L
Hg, Cd < 0.001 µg/L
Zn < 1.0 µg/L
Ge < 0.1 µg/L
Precision ( RSD ) : < 1.0
Linear range : More than 3 orders of magnitude
FTIR Spectrometer LIR-B10
Spectral Range : 7800 cm-1 to 350 cm-1
Resolution : 0.85 cm-1
Wave number precision : ± 0.01 cm-1
Scanning speed : Microprocessor control, different scanning speed selectable
Handheld XRF Spectrometer LXRF-B10
Analytical Method : Energy dispersive X-ray fluorescence analytical Method
Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
Range : Simultaneous detector
Content measurement range : ppm to 100%
Handheld XRF Spectrometer LXRF-B11
Analytical Method : Energy dispersive X-ray fluorescence analytical Method
Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
Range : Simultaneous detector
Content measurement range : ppm to 99.99%
ICP spectrometer LICP-A10
Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
Wavelength range ( 2400 lines / mm ) : 180 to 800 nm
Temperature : 20 ~ 28 °C
Elements per minute : 26 elements
ICP Spectrometer LICP-A11
Wavelength range : 180 to 900 nm
Elements per minute : 15 elements
Temperature : 29 °C
Incident slit : 25 µm
ICP Spectrometer LICP-A12
Wavelength range : 195 to 800 mm
Elements per minute : 10 elements
Temperature range : 32 °C
Incident slit : 20 µm
ICP Spectrometer LICP-B10
Monochromator Specifications :
Optical type Czerny turner
Resolution ≤ 0.015nm (3600 line grating)
≤ 0.030nm (2400 line grating)
Focal length 1000 mm
Grating specifications huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
Wavelength range 195 to 500 nm for 3600 line grating
195 to 800 nm for 2400 line grating
Solid State Power Specifications :
Frequency 27.12 MHz
Frequency stability: < 0.05%
Spray chamber Scott double pass spray chamber
Output power 800 W to 1600 W, adjustable with power efficiency more than 65%
Output power stability ≤ 0.05%
Induction coil 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
Technical Specifications :
Suitable sample content range Liquid sample: 0.01 ppm to several thousand ppm
Solid or power sample: 0.001% to 70%
Repeatability short-term stability- RSD ≤ 1.5%
Long-term stability: RSD ≤ 2%
Test speed 5 to 8 elements / min
Limits of detection (LOD, µg/L) for most elements 1ppb to 10ppb
Control Circuit :
Photomultiplier tube specification R212 / R928
Negative high voltage -50 to -1000 V
Circuit measuring range (10-12 to 10 -4) A
Signal acquisition VF conversion
XRD Diffractometer LXRD-A10
X-ray Tuble : Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
Focus Size : 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
Stability : ≤ 0.01 %
Tube Current : 5 to 80 mA
XRF-Spectrometer LXRF-A10
Measureable elements : S to U
Detection limit : 1 ppm
Temperature : 15 ~ 30 °C
Elemental content : 1 ppm to 99 %