ICP spectrometer LICP-A10 detects trace elements using argon plasma where the atomized liquid sample is injected. With an analyzing rate of 26 elements per minute results can be achieved with lower levels of detection and measurement of trace and ultra-trace elements. Elements can be traced from liquid and solid samples. Detection of liquid flow from the spray chamber by optical drain sensor offers exceptional sensitivity and accuracy.
Specifications
Wavelength range ( 3600 lines / mm ) | 180 to 500 nm |
Wavelength range ( 2400 lines / mm ) | 180 to 800 nm |
Temperature | 20 ~ 28 °C |
Elements per minute | 26 elements |
Humidity | 70% |
Focal length | 1000 mm |
Standard deviation | RSD ≤ 1.0 % |
Correlation coefficient | ≥ 0.9998 |
Gas source | Argon ( 99.99 % ) |
Plasma gas flow meter | 100 ~ 1000 L / h |
Auxillary gas flow meter | 10 ~ 100 L / h |
Carrier gas flow meter | 10 ~ 100 L / h |
Cooling water flow rate | 5 liters per min |
Cooling water temperature | 21 ~ 26 °C |
Water outlet diameter | Ø 10 mm |
Line dispersion rate | 0.26 nm |
Resolving power | ≤ 0.008 nm |
Incident slit | 20 µm |
Co-axial sprayer diameter | 6 mm |
Coil diameter | 25 mm ( 3 turn ) |
Double room fog diameter | 34 mm |
Quartz tube torch diameter | 20 mm |
Mirror dimensions | 78 x 105 x 16 mm |
Features
Scanning range variance ( 190 nm to 500 nm / 190 nm to 800 nm )
Rapid analysis – 26 elements per minute
Temperature range – 20 to 28 °C
Optical pathway – Czerny-turners
Low detection limit
Detection of multi-elements including non-metallic
Single and multi-element measurement method
Indication for wavelength error and repeatability
Range of measurement – common to trace
Applications
Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection
Element Detection Limits (Unit - µg / ml)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Request Quote
Monochromator Specifications |
|
||||||||||
Solid State Power Specifications |
|
||||||||||
Technical Specifications |
|
||||||||||
Control Circuit |
|
||||||||||
Working Environment |
|
||||||||||
Other Details |
|
Wavelength range | 180 to 900 nm |
Elements per minute | 15 elements |
Temperature | 29 °C |
Incident slit | 25 µm |
Standard deviation | RSD ≤ 2 % |
Correlation coefficient | ≥ 0.9995 % |
Gas source | Argon ( 99.99 % ) |
Plasma gas flow meter | 100 – 1000 L / h ( 1.6 - 16 L / min ) |
Auxillary gas flow meter | 10 – 100 L / h ( 0.16 – 1.66 L / min ) |
Carrier gas flow meter | 0 ~ 5 L / min |
Cooling water flow rate | 5 L / min |
Cooling water temperature | 20 ~ 26 °C |
Water outlet diameter | 10 mm |
Line dispersion rate | 0.26 nm |
Resolving power | ≤ 0.007 nm |
Co-axial sprayer diameter | 6 mm |
Coil diameter | 25 mm |
Double room fog diameter | 34 mm |
Quartz tube torch diameter | 20 mm |
Mirror dimensions | 80 x 110 x 16 mm |
Wavelength range | 195 to 800 mm |
Elements per minute | 10 elements |
Temperature range | 32 °C |
Incident slit | 20 µm |
Standard deviation | RSD ≤ 2 % |
Correlation coefficient | ≥ 0.9995 % |
Gas source | Argon ( 99.99 % ) |
Plasma gas flow meter | 100 ~ 1000 L / h ( 1.6 - 16 L / min ) |
Auxillary gas flow meter | 10 ~ 100 L / h ( 0.16 – 1.66 L / min ) |
Carrier gas flow meter | 0 ~ 5 L / min |
Cooling water flow rate | 5 L / min |
Cooling water temperature | 20 ~ 26 °C |
Water outlet diameter | 10 mm |
Line dispersion rate | 0.26 nm |
Resolving power | ≤ 0.008 nm |
Co-axial sprayer diameter | 6 mm |
Coil diameter | 25 mm ( 3 turn ) |
Double room fog diameter | 34 mm |
Quartz tube torch diameter | 20 mm |
Mirror dimensions | 78 x 105 x 16 mm |
Measureable elements | S to U |
Detection limit | 1 ppm |
Temperature | 15 ~ 30 °C |
Elemental content | 1 ppm to 99 % |
Repeatability | 0.001 |
Stability | 0.001 |
Power supply | AC 220 V ± 5 V |
Dimensions | 550 x 410 x 320 mm |
Weight | 45 kg |
Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
Range | Simultaneous detector |
Content measurement range | ppm to 100% |
Detector | SDD detector, Simultaneous analysis 40 elements |
Detector resolution | Minimum can reach 128 eV |
Detection limit | Minimum detection limits at 1 to 500 ppm |
Detection Objective Solid, liquid, powder | Detection Objective Solid, liquid, powder |
The detection time | 1 to 60 seconds (a second report results) |
Excitation source | 50 kV/200 uA- silver target end window integrated miniature X ray tube and high voltage power supply |
Collimator and filter | Collimator diameters are 4.0 mm and 2.0 mm, 6 kinds of filters with automatic switching functions |
Camera system | Built-in 500 W pixels high definition camera, to observe testing position at any time |
Display screen | Brand new 5 inch transflective LCD touch screen, the resolution is 1080×720 |
Built-in system | GPS, WIFI, Bluetooth |
Power Supply | Rechargeable lithium battery, standard is 9000 mAh, sustainable work up to 12 hours |
Ambient temperature | -20 to 50°C |
Relative Humidity | ≤ 90% |
Data transmission | Digital multi-channel technology, SPI data transmission, quick analysis, the high count rate; waterproof mini USB, and can be connected with a desktop computer |
Warning-Signalling System | Green light means power on, red flushing means testing and yellow flushing means the problems |
Dimension (L×W×H) | 244 × 90 × 330 mm |
Weight | 1.7 kg |
Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
Range | Simultaneous detector |
Content measurement range | ppm to 99.99% |
Detector | SDD detector or fast SDD detector (optional) |
Detector resolution | Minimum can reach 128 eV |
Detection limit | Minimum detection limits at 1 to 500 ppm |
Detection Objective Solid, liquid, powder | Solid, liquid, powder |
The detection time | 1 to 60 seconds (a second report results) |
Excitation source | 50 kV/200 uA- silver target end window integrated miniature X ray tube and high voltage power supply |
Collimator and filter | Collimator diameters are 4.0 mm and 2.0 mm, 6 kinds of filters with automatic switching functions |
Camera system | Built-in 500 W pixels high definition camera, to observe testing position at any time |
Display screen | Brand new 5 inch transflective LCD touch screen, the resolution is 1080×720 |
Built-in system | GPS, WIFI, Bluetooth |
Power Supply | Rechargeable lithium battery, standard is 27000 mAh, sustainable work up to 12 hours |
Ambient temperature | -20 to 50°C |
Relative Humidity | ≤ 90% |
Data transmission | Digital multi-channel technology, SPI data transmission, quick analysis, the high count rate; waterproof mini USB, and can be connected with a desktop computer |
Warning-Signalling System | Green light means power on, red flushing means testing and yellow flushing means the problems |
Dimension (L×W×H) | 244 × 90 × 330 mm |
Weight | 1.7 kg |