Benchtop Conductivity Meter LBCM-A13 with 7 inch display conducts up to 5 point calibration, automatically recognizes calibration standards. Comes with 03 reading mode: fast, medium, strict, custom to balance the work operations. Complied with GLP specifications, meter allows user to carry data statistics, measure results, carry out and review, analyze, and compare statistics.
Specifications
Conductivity measurement range | 0.000 μS/cm to 3000mS/cm | ||||||
Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm | ||||||
TDS measurement range | 0.000 mg/L to 1000g/L | ||||||
Salinity measurement range | 0.00 to 8.00 % | ||||||
Temperature measurement range | -5.0 to 135.0 °C | ||||||
Conductivity accuracy | ± 0.5 % FS | ||||||
Resistivity accuracy | ± 0.5 % FS | ||||||
TDS accuracy | ± 0.5 % FS | ||||||
Salinity accuracy | ± 0.1 % | ||||||
Temperature accuracy | ± 0.1 °C | ||||||
Automatic temperature compensation | Yes | ||||||
Automatic calibration | Yes | ||||||
Automatic range switching | Yes | ||||||
Calibration function | Yes | ||||||
Reading mode |
|
||||||
Data interface | RS232, USB | ||||||
Data storage | 1000 sets | ||||||
Complied with GLP specifications | Yes | ||||||
Power supply | (Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A) | ||||||
Dimension | 280 × 280 × 130 mm | ||||||
Weight | 2.5 kg |
Features
7 inch color touch screen
Automatic temperature compensation and calibration
Electrode correction function
5 point conductivity calibrations
Intelligent operating system
100 sets of measurement data
Different conductivity compensation methods (includes pure water)
Different salinity compensation methods (includes saline , brine water)
Supports USB, RS232 connection with PC, serial printer
Supports firmware upgrade, support U disk hot swap
Applications
Used to test Conductivity, TDS, Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.
Standard Accessories
Accessories no. | Name |
1 | Conductivity Electrode |
2 | Temperature sensor |
3 | Electrode holder |
4 | AC/DC Power Adapter |
5 | USB Communication Line |
Optional Accessories
Accessories No. | Name |
1 | Conductivity Probe (K=0.01) |
2 | Conductivity Probe (K=0.1) |
3 | Conductivity Probe (K=1) |
4 | Conductivity Probe (K=10) |
Request Quote
Temperature compensation | 0 to 100°C, 32°F to 212°F Manual or Automatic |
Hold function | Manual or automatic endpoint detection |
Stability criteria | Standard or High-accuracy |
Interval readings | 10, 30, 60 seconds, 10, 30 minutes or Off |
Calibration due alarm | 1 to 31 days |
Memory | Stores up to 1000 data sets |
Output | USB communication interface |
Display | 7 inch TFT LCD |
pH Specifications | Measuring range -2.000 to 20.000 pH Accuracy ± 0.002 pH Resolution 0.001, 0.01 pH Calibration points 1 to 5 points |
mV Specifications | Measuring range ± 2000 mV Accuracy ± 0.1 mV Resolution 0.1 mV Calibration points 1 point ( Only for relative mV mode ) |
Temperature Specifications | Measuring range 0 ~ 105 °C, 32 °F ~ 221 °F Accuracy ± 0.5 °C, ± 0.9 °F Resolution 0.1 °C, 0.1 °F Calibration points 1 point |
Power | DC 1 2V / 2A power adapter |
Dimensions ( L x W x H ) | 240 × 220 × 80 mm |
Weight | 1.7 kg |
pH measurement range | 0.00 to 14.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 2 points |
Calibration solutions | USA (pH 4.0/7.00/10.01) |
ORP measurement range | |
ORP accuracy | |
ORP calibration points | |
ORP calibration range | |
ORP calibration solutions | |
Temperature compensation | 0 to 100°C |
Compensation mode | Manual or automatic |
mV range | -1999 to 1999 mV |
mV accuracy | ±1mV |
mV resolution | 1 mV |
Temperature range | 0 to 100°C, 32 to 212°F |
Temperature accuracy | ±1°C |
Stability conditions | |
Calibration due | |
memory | |
Output | |
Temperature resolution | 1°C |
Hold function | |
Power off | |
Reset function | |
Connector | BNC |
Display | LCD |
Dimension (L*W*H) | 210×205×65 mm |
Weight | 1.5 kg |
Power | DC9V, Ac adapter, AC220V /50Hz |
pH measurement range | -1.00 to 15.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 1-3 points |
Calibration solutions | USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18) |
ORP measurement range | |
ORP accuracy | |
ORP calibration points | |
ORP calibration range | |
ORP calibration solutions | |
Temperature compensation | 0 to 100°C, 32 to 212°F |
Compensation mode | Manual or automatic |
mV range | -1000 to 1000 mV |
mV accuracy | ±1mV |
mV resolution | 1 mV |
Temperature range | 0 to 105°C, 32 to 221°F |
Temperature accuracy | ±1°C |
Stability conditions | |
Calibration due | |
memory | |
Output | |
Temperature resolution | 0.1°C |
Hold function | Manual or automatic endpoint detection |
Power off | Manual or automatic (180 minutes after last key is pressed) |
Reset function | Yes |
Connector | BNC |
Display | LCD |
Dimension (L*W*H) | 210×205×75 mm |
Weight | 1.5 kg |
Power | DC9V, AC adapter, AC220V/50Hz |
pH measurement range | -2.000 to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH resolution | |
Calibration points | 1-5 points |
Calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration range | ±200 mV |
ORP calibration solutions | mV & relative mV |
Temperature compensation | 0 to 100°C, 32 to 212°F |
Compensation mode | Manual or automatic |
mV range | |
mV accuracy | |
mV resolution | |
Temperature range | |
Temperature accuracy | |
Stability conditions | Low or high |
Calibration due | 0 to 31 days |
memory | Stores up to 500 data sets |
Output | USB communication interface |
Temperature resolution | |
Hold function | |
Power off | |
Reset function | |
Connector | BNC |
Display | LCD |
Dimension (L*W*H) | 210×188×60 mm |
Weight | 1.5 kg |
Power | DC5V using AC adapter, AC220V /50 Hz |
Conductivity measurement range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy | ± 1 % F.S. |
Conductivity resolution | 0.01, 0.1, 1 |
Conductivity calibration solutions | 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm |
Conductivity calibration points | 1 - 3 points |
Temperature compensation range & mode | Manual or automatic, 0 to 100 °C , 32 to 212 °F |
Temperature range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 1° |
Temperature resolution | 0.1 °C |
Temperature coefficient | 0.0 to 10.0 % per °C |
Cell constant | K= 0.1, 1, 10 or User-defined |
Data hold function | Manual or automatic |
Connector | 6 - pin mini plug |
Display | LCD (315 × 75 mm) |
Power | DC 6 V / 400 mA power adapter, AC 220 V / 50Hz |
Dimension (L × W × H) | 210 × 205 × 75 mm |
Weight | 1.5 kg |
Conductivity Mode |
|
||||||||||||
TDS Mode |
|
||||||||||||
Temperature Mode |
|
||||||||||||
Cell constant | K=0.1, 1, 10 | ||||||||||||
Power requirements | DC 9 V, using AC adapter, AC 220 V, 50 Hz | ||||||||||||
Dimension (L×W×H) | 210 × 205 × 75 mm | ||||||||||||
Weight | 1.5 kg |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
Calibration points | 1 - 2 points |
Sensor type | Polarographic DO probe |
Temperature compensation range | 0 to 40 °C, 32 to 104 °F |
Barometric pressure correction | 60.0 to 112.5 kPa, 450 to 850 mmHg |
Salinity correction | 0 - 35 g / L |
% of saturation of oxygen range | 0.0 to 200.0 % |
% of saturation of oxygen accuracy | ± 10 % F.S. |
% of saturation of oxygen resolution | 0.001 |
System menu | Allows setting of 6 parameters |
Data hold function | Manual or automatic endpoint detection |
Power off | Manual or automatic (180 minutes) |
Reset function | Yes |
Memory | |
Display | Backlit LCD (135 × 75 mm) |
Connector | 6 pin mini plug |
Stability conditions | |
Calibration due | |
Power | DC 9 V, use of SC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 205 × 75 mm |
Weight | 1.5 kg |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Calibration points | 1 - 2 points |
Sensor type | Polarographic DO probe |
Temperature compensation range | 0 to 50 °C, 32 to 122 °F |
Barometric pressure correction | 60.0 to 112.5 kPa, 450 to 850 mmHg |
Salinity correction | 0 - 50 g / L |
% of saturation of oxygen range | 0.0 to 200.0 % |
% of saturation of oxygen accuracy | ± 2.0 % F.S. |
% of saturation of oxygen resolution | 0.1, 1 % |
System menu | Allows setting of 9 parameters |
Data hold function | Manual or automatic endpoint detection |
Power off | Manual or automatic (10, 20, 30 minutes) |
Reset function | Yes |
Memory | Stores up to 50 data sets |
Display | Backlit LCD (130 × 110 mm) |
Connector | 6 pin mini plug |
Stability conditions | Low or high |
Calibration due | 0 to 31 days |
Power | DC 5 V, use of AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Ion measurement range | Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration points | 2 to 5 points |
Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
mV range | (-1999.9) to 1999.9 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1 mV |
Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1°C |
Temperature compensation | 0 to 100 °C, 32 to 212 °F |
Compensation mode | Manual or automatic |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Stability condition | Low or high |
Calibration due | 0 to 31 days |
Power off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Ion measurement range | F range: 1 × 106M – saturation, 0.02 ppm to saturation |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration points | 2 to 5 points |
Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
mV range | (-1999.9) to 1999.9 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1 mV |
Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1°C |
Temperature compensation | 0 to 100 °C, 32 to 212 °F |
Compensation mode | Manual or automatic |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Stability condition | Low or high |
Calibration due | 0 to 31 days |
Power off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Ion measurement range | Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration points | 2 to 5 points |
Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
mV range | (-1999.9) to 1999.9 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1 mV |
Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1°C |
Temperature compensation | 0 to 100 °C, 32 to 212 °F |
Compensation mode | Manual or automatic |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Stability condition | Low or high |
Calibration due | 0 to 31 days |
Power off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Ion measurement range | Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration points | 2 to 5 points |
Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
mV range | (-1999.9) to 1999.9 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1 mV |
Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1°C |
Temperature compensation | 0 to 100 °C, 32 to 212 °F |
Compensation mode | Manual or automatic |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Stability condition | Low or high |
Calibration due | 0 to 31 days |
Power off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Conductivity measurement range | 1.0 to 199.9 µS/cm |
Type of conductivity | Low range conductivity |
Conductivity accuracy | ± 1 % F.S. |
Conductivity calibration points | 1 point |
Conductivity calibration solutions | 146.5 µS/cm |
Sensor type | Platinum sensor |
Temperature compensation | 0 °C - 50 °C |
Temperature coefficient | 2 % per °C |
Cell constant | K=1 |
Normalization temperature | 25 °C |
Data hold function | Manual |
Display | LCD screen |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G134” batteries |
Battery life | Approximately 150 hours |
Dimension (L*dia.) | 185 × 40 mm |
Weight | 100 g |
Conductivity measurement range | 10 to 1999 µS/cm |
Type of conductivity | Mid-range conductivity |
Conductivity accuracy | ± 1 % F.S. |
Conductivity calibration points | 1 point |
Conductivity calibration solutions | 1413 µS/cm |
Sensor type | Platinum sensor |
Temperature compensation | 0 °C - 50 °C |
Temperature coefficient | 2 % per °C |
Cell constant | K=1 |
Normalization temperature | 25 °C |
Data hold function | Manual |
Display | LCD screen |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G134” batteries |
Battery life | Approximately 150 hours |
Dimension (L*dia.) | 185 × 40 mm |
Weight | 100 g |
Conductivity measurement range | 0.1 to 19.99 mS/cm |
Type of conductivity | High range conductivity |
Conductivity accuracy | ± 1 % F.S. |
Conductivity calibration points | 1 point |
Conductivity calibration solutions | 12.88 mS/cm |
Sensor type | Platinum sensor |
Temperature compensation | 0 °C - 50 °C |
Temperature coefficient | 2 % per °C |
Cell constant | K=1 |
Normalization temperature | 25 °C |
Data hold function | Manual |
Display | LCD screen |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G134” batteries |
Battery life | Approximately 150 hours |
Dimension (L*dia.) | 185 × 40 mm |
Weight | 100 g |
Sensor type | Platinum sensor |
Connector | 6 pin |
ORP measurement range | (-999) to 999 mV |
ORP accuracy | ± 2 mV |
ORP resolution | 1 mV |
ORP calibration solutions | mV & relative mV |
ORP calibration points | 1 point (only for relative mV mode) |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Display | LCD screen |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 2 × 1.5V “AAA” batteries |
Battery life | 200 hours |
Dimension (L*dia.) | 175 × 40 mm |
Weight | 100 g |
Sensor type | |
Connector | BNC |
ORP measurement range | (-999) to 999 mV |
ORP accuracy | ± 2 mV |
ORP resolution | 1 mV |
ORP calibration solutions | mV & relative mV |
ORP calibration points | 1 point (only for relative mV mode) |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Display | LCD screen |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 2 × 1.5V “AAA” batteries |
Battery life | 200 hours |
Dimension (L*dia.) | 175 × 40 mm |
Weight | 100 g |
pH measurement range | 0.0 - 14.00 pH |
Shape of electrode | Round glass pH electrode |
pH measurement accuracy | ± 0.1 pH |
Calibration point | 2 points |
Calibration solution | USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18) |
Operating temperature | |
Temperature accuracy | |
Temperature compensation range | |
Data hold function | Manual or Automatic |
Connector | 6 pin |
Shutdown mode | Manual or automatic ( 8 minutes without key operations) |
Dimension (length × diameter) | 185 × 40 mm |
Weight | 100 g |
Power type | 3 × 1.5 V G13A button battery 3 |
Battery life | About 150 hours |
pH measurement range | 0.0 - 14.00 pH |
Shape of electrode | Flat pH electrode |
pH measurement accuracy | ± 0.1 pH |
Calibration point | 2 points |
Calibration solution | USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18) |
Operating temperature | |
Temperature accuracy | |
Temperature compensation range | |
Data hold function | Manual or Automatic |
Connector | 6 pin |
Shutdown mode | Manual or automatic ( 8 minutes without key operations) |
Dimension (length × diameter) | 185 × 40 mm |
Weight | 100 g |
Power type | 3 × 1.5 V G13A button battery 3 |
Battery life | About 150 hours |
pH measurement range | 0.0 - 14.00 pH |
Shape of electrode | Long distance planar pH electrode |
pH measurement accuracy | ± 0.1 pH |
Calibration point | 2 points |
Calibration solution | USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18) |
Operating temperature | |
Temperature accuracy | |
Temperature compensation range | |
Data hold function | Manual or Automatic |
Connector | 6 pin |
Shutdown mode | Manual or automatic ( 8 minutes without key operations) |
Dimension (length × diameter) | 185 × 40 mm |
Weight | 100 g |
Power type | 3 × 1.5 V G13A button battery 3 |
Battery life | About 150 hours |
pH measurement range | pH range: (-1.00) to 15.00 pH |
Shape of electrode | Flat pH electrode |
pH measurement accuracy | ± 0.01 pH |
Calibration point | 1 - 3 points |
Calibration solution | USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18) |
Operating temperature | |
Temperature accuracy | |
Temperature compensation range | 0 °C to 60 °C, Automatic |
Data hold function | Manual or Automatic |
Connector | 6 pin |
Shutdown mode | Manual or automatic ( 8 minutes without key operations) |
Dimension (length × diameter) | 185 × 40 mm |
Weight | 100 g |
Power type | 2 × 1.5 V AAA batteries |
Battery life | About 200 hours |
Salinity measurement range | 0.00 to 10.00 ppt |
Salinity accuracy | ± 1 % F.S |
Conductivity range | 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm |
Calibration solutions | 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
Conductivity accuracy | ± 1 % F.S |
Calibration points | 1 - 3 points |
Temperature compensation range | 0 °C to 60 °C, 32 °F to 140 °F |
Temperature accuracy | ± 1 °C |
Temperature coefficient | 2 % per °C |
Normalization temperature | 25 °C |
Reset function | Yes |
Cell constant | K=1 |
Data hold function | Manual or automatic endpoint detection |
Power off | Manual or automatic (8 minute after last key is pressed) |
Sensor type | Platinum sensor |
Battery life | Approximately 200 hours |
Power | 2 × 1.5 V AAA batteries |
Dimension (L × Dia.) | 185 × 40 mm |
Weight | 100 g |
Salinity measurement range | 0.00 to 80.00 ppt |
Salinity accuracy | ± 1 % F.S |
Conductivity range | 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm |
Calibration solutions | 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
Conductivity accuracy | ± 1 % F.S |
Calibration points | 1 - 3 points |
Temperature compensation range | 0 °C to 60 °C, 32 °F to 140 °F |
Temperature accuracy | ± 1 °C |
Temperature coefficient | 2 % per °C |
Normalization temperature | 25 °C |
Reset function | Yes |
Cell constant | K=1 |
Data hold function | Manual or automatic endpoint detection |
Power off | Manual or automatic (8 minute after last key is pressed) |
Sensor type | Platinum sensor |
Battery life | Approximately 200 hours |
Power | 2 × 1.5 V AAA batteries |
Dimension (L × Dia.) | 185 × 40 mm |
Weight | 100 g |
TDS range | 0.5 - 100.0 ppm |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.4 to 1.0 (default 0.5) |
Calibration points | 1 point |
TDS type range | Low range TDS |
Calibration solutions | 71.8 ppm |
Type of sensor | Platinum sensor |
Temperature compensation | 0 °C - 50 °C, Automatic |
Temperature coefficient | 2 % per °C |
Normalization temperature | 25 °C |
Operating temperature | 0 °C - 60 °C, 32 °F - 140 °F |
Connector | 6 pin |
Display | LCD screen |
Data hold function | Manual |
Battery life | Approximately 150 hours |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G13A” |
Dimension (L × dia.) | 185 × 40 mm |
Weight | 100 g |
TDS range | 5 - 1000 ppm |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.4 to 1.0 (default 0.5) |
Calibration points | 1 point |
TDS type range | Mid-range TDS |
Calibration solutions | 744.7 ppm |
Type of sensor | Platinum sensor |
Temperature compensation | 0 °C - 50 °C, Automatic |
Temperature coefficient | 2 % per °C |
Normalization temperature | 25 °C |
Operating temperature | 0 °C - 60 °C, 32 °F - 140 °F |
Connector | 6 pin |
Display | LCD screen |
Data hold function | Manual |
Battery life | Approximately 150 hours |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G13A” |
Dimension (L × dia.) | 185 × 40 mm |
Weight | 100 g |
TDS range | 0.05 - 10.00 ppt |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.4 to 1.0 (default 0.5) |
Calibration points | 1 point |
TDS type range | High range TDS |
Calibration solutions | 7447 ppm |
Type of sensor | Platinum sensor |
Temperature compensation | 0 °C - 50 °C, Automatic |
Temperature coefficient | 2 % per °C |
Normalization temperature | 25 °C |
Operating temperature | 0 °C - 60 °C, 32 °F - 140 °F |
Connector | 6 pin |
Display | LCD screen |
Data hold function | Manual |
Battery life | Approximately 150 hours |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G13A” |
Dimension (L × dia.) | 185 × 40 mm |
Weight | 100 g |
TDS range | 0 - 20 ppt |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.1 to 1.0 (default 0.5) |
Calibration points | 1 - 3 points |
TDS type range | Low range TDS |
Calibration solutions | 100 ppm, 1000 ppm, 10 ppt |
Type of sensor | Platinum sensor |
Temperature compensation | 0 °C - 60 °C, Automatic |
Temperature coefficient | 2 % per °C |
Normalization temperature | 25 °C |
Operating temperature | 0 °C - 60 °C, 32 °F - 140 °F |
Connector | 6 pin |
Display | LCD screen |
Data hold function | Manual |
Battery life | Approximately 150 hours |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 2 × 1.5 V “AAA” |
Dimension (L × dia.) | 185 × 40 mm |
Weight | 100 g |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
Calibration points | 1 - 2 points |
Sensor type | Polarographic DO probe |
Temperature compensation range | 0 to 40 °C, 32 °F to 104 °F |
Barometric pressure correction | 60.0 to 112.5 kPa, 450 to 850 mmHg |
Salinity correction | 0 - 35 g / L |
% of saturation of oxygen range | 0.0 to 200.0 % |
% of saturation of oxygen accuracy | ± 10 % F.S. |
% of saturation of oxygen resolution | 0.001 |
System menu | |
Data hold function | Manual |
Power off | |
Reset function | Yes |
Memory | Stores up to 48 sets of data |
Output | USB communication interface |
Display | LCD screen |
Connector | 4-pin mini plug |
Calibration due | |
Stability connector | |
Battery life | Approximately 150 hours |
Power | 1 x 9 V / 800 mA battery |
Dimension (L x W x H) | 185 × 88 × 32 mm |
Weight | 300 g |
Dissolved oxygen range | 0.0 - 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Calibration points | 1 - 2 points |
Sensor type | Polarographic DO probe |
Temperature compensation range | 0 to 50 °C, 32 °F to 122 °F, Automatic |
Barometric pressure correction | 60.0 to 112.5 kPa, 450 to 850 mmHg |
Salinity correction | 0 to 50 g / L |
% of saturation of oxygen range | 0.0 to 200.0 % |
% of saturation of oxygen accuracy | ± 2.0 % F.S. |
% of saturation of oxygen resolution | 0.1, 1 % |
System menu | Allows setting of 9 parameters |
Data hold function | Manual or automatic endpoint detection |
Power off | Manual or automatic (10, 20, 30 minutes) |
Reset function | Yes |
Memory | Stores up to 500 data sets |
Output | USB communication interface |
Display | Backlit LCD (130 × 110 mm) |
Connector | 6 pin mini plug |
Calibration due | 0 to 31 days |
Stability connector | Low or high |
Battery life | |
Power | 3 x 1.5 V “AA” batteries |
Dimension (L x W x H) | 170 × 85 × 30 mm |
Weight | 300 g |
pH mode |
|
||||||||||||||||
ORP measurement |
|
||||||||||||||||
Ion measurement |
|
||||||||||||||||
Conductivity measurement |
|
||||||||||||||||
TDS measurement |
|
||||||||||||||||
Salinity measurement |
|
||||||||||||||||
Resistivity |
|
||||||||||||||||
Dissolved oxygen |
|
||||||||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic | ||||||||||||||||
Stability conditions | Low or high | ||||||||||||||||
Calibration due | 0 to 31 days | ||||||||||||||||
Memory | Stores up to 500 data sets | ||||||||||||||||
Output | USB communication interface | ||||||||||||||||
Connector | |||||||||||||||||
Display | |||||||||||||||||
Dimension (L × W × H) | 185 × 88 × 32 mm | ||||||||||||||||
Weight | 300 g | ||||||||||||||||
Power supply | 3 × 1.5 V “AA batteries or DC 5 V power adapter |
pH mode |
|
||||||||||||||||
ORP measurement |
|
||||||||||||||||
Ion measurement |
|
||||||||||||||||
Conductivity measurement |
|
||||||||||||||||
TDS measurement |
|
||||||||||||||||
Salinity measurement |
|
||||||||||||||||
Resistivity |
|
||||||||||||||||
Dissolved oxygen |
|
||||||||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic | ||||||||||||||||
Stability conditions | Low or high | ||||||||||||||||
Calibration due | 0 to 31 days | ||||||||||||||||
Memory | Stores up to 500 data sets | ||||||||||||||||
Output | USB communication interface | ||||||||||||||||
Connector | |||||||||||||||||
Display | |||||||||||||||||
Dimension (L × W × H) | 185 × 88 × 32 mm | ||||||||||||||||
Weight | 300 g | ||||||||||||||||
Power supply | 3 × 1.5 V “AA batteries or DC 5 V power adapter |
pH mode |
|
||||||||||||||||
ORP measurement |
|
||||||||||||||||
Conductivity measurement |
|
||||||||||||||||
TDS measurement |
|
||||||||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic | ||||||||||||||||
Stability conditions | Low or high | ||||||||||||||||
Calibration due | 0 to 31 days | ||||||||||||||||
Memory | Stores up to 500 data sets | ||||||||||||||||
Output | USB communication interface | ||||||||||||||||
Connector | BNC, 6- pin MINI connector | ||||||||||||||||
Display | LCD | ||||||||||||||||
Dimension (L × W × H) | 170×85×30 mm | ||||||||||||||||
Weight | 300 g | ||||||||||||||||
Power supply | 3 × 1.5 V “AA batteries or DC 5 V power adapter |
pH mode |
|
||||||||||||||
ORP measurement |
|
||||||||||||||
Dissolved oxygen |
|
||||||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic | ||||||||||||||
Stability conditions | Low or high | ||||||||||||||
Calibration due | 0 to 31 days | ||||||||||||||
Memory | Stores up to 500 data sets | ||||||||||||||
Output | USB communication interface | ||||||||||||||
Connector | BNC, 6- pin MINI connector | ||||||||||||||
Display | LCD | ||||||||||||||
Dimension (L × W × H) | 170×85×30 mm | ||||||||||||||
Weight | 300 g | ||||||||||||||
Power supply | 3 × 1.5 V “AA batteries or DC 5 V power adapter |
pH range | (-2.00) to 16.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 2 points |
Calibration solutions | USA (pH 4.01 / 7.00 / 10.01), |
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic |
mV range | (-1999) to 1999 mV |
mV accuracy | ± 1 mV |
mV resolution | 1 mV |
Temperature measuring range | 0 to 100 °C, 32 to 212 °F |
Temperature accuracy | ± 1 °C |
Temperature resolution | 0.1 °C |
Hold function | Manual |
Storage/memory | Stores up to 50 data sets |
Communication output | USB |
Connector | BNC |
Dimension (L × W × H) | 185 × 88 × 32 mm |
Weight | 300 g |
Battery life | About 150 hours |
Power | 9 V / 800 mA battery |
pH range | (-2.00) to 20.00 pH |
pH accuracy | ± 0.002 pH |
pH resolution | 0.1, 0.01, 0.001 pH |
Calibration points | 1 - 5 points |
Calibration solutions | USA (pH 4.01 / 7.00 / 10.01 / 12.45), NIST(pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45), DIN (pH 1.09 / 4.65 / 6.79 / 9.23 / 12.75) or user defined |
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic |
mV range | (-1999) to 1999 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1, 1 mV |
Temperature measuring range | 0 to 100 °C, 32 to 212 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1 °C |
Hold function | Manual |
Storage/memory | Stores up to 500 data sets |
Communication output | USB interface |
Connector | BNC |
Dimension (L × W × H) | 170 × 85 × 30 mm |
Weight | 300 g |
Battery life | About 150 hours |
Power | 4.5 V “AA batteries or DC 5 V power adapter |
COD |
|
||||||||||||||||||||||
Ammonia nitrogen |
|
||||||||||||||||||||||
Total phosphorous |
|
||||||||||||||||||||||
Turbidity |
|
||||||||||||||||||||||
Light source life | 100000 hours | ||||||||||||||||||||||
Optical stability | ≤ 0.001 A/ 10 min | ||||||||||||||||||||||
No. of curves | 166 | ||||||||||||||||||||||
Storage data | 12000 | ||||||||||||||||||||||
Display | LCD (320 × 240) | ||||||||||||||||||||||
Interface | USB | ||||||||||||||||||||||
Power supply | AC 200 V | ||||||||||||||||||||||
Dimension | 550 × 300 × 250 mm | ||||||||||||||||||||||
Gross Weight | 21 kg |
COD |
|
||||||||||||||||||||||
Ammonia nitrogen |
|
||||||||||||||||||||||
Total phosphorous |
|
||||||||||||||||||||||
Turbidity |
|
||||||||||||||||||||||
Light source life | 100000 hours | ||||||||||||||||||||||
Optical stability | ≤ 0.001 A/ 10 min | ||||||||||||||||||||||
No. of curves | 56 | ||||||||||||||||||||||
Storage data | 12000 | ||||||||||||||||||||||
Display | LCD (320 × 240) | ||||||||||||||||||||||
Interface | USB | ||||||||||||||||||||||
Power supply | AC 200 V | ||||||||||||||||||||||
Dimension | 450 × 300 × 250 mm | ||||||||||||||||||||||
Gross Weight | 18 kg |
Light source | LED/860 nm (Wavelength) |
Readings display | LCD |
Unit switches | NTU, FTU, EBC, ASBC |
Measurement range | 0.00-20.0; 20.01-200; 200.01-1000 NTU |
Minimum reading | 0.001 |
Calibration modes | 6 |
Allowable error of indication | ≤±6% |
Zero Drift | ≤±0.5%FS |
Stability of indication | ≤±0.5% FS |
Repeatability | ≤0.5% |
Sample bottle | Φ 25 mm×65 mm |
Sample volume | 20-25 ml |
Interface | USB |
Data storage | 2000 sets |
Net Weight | 650 gm |
Measuring range (NTU) | 0 to 200 |
Minimum readout value (NTU) | 0.1 |
Calibration point | Nil |
Sample volume | 5 to 10 ml |
Principle method | 90° scattered light |
Operating temperature | 5 to 40°C |
Working temperature | 5 to 40°C |
Light source | Infrared-emitting diode (850 nm λ) |
Detector | Silicon photodiode |
Error value | ± 6 % (± 2 % F.S) |
Zero drift | ± 0.5 % F.S. |
Reset functions | Yes |
Memory | Stores up to 20 sets data |
Output | |
Dimension | 370 × 260 × 150 mm |
Weight | 1.5 kg |
Power batteries | DC 1.5 V, 5 AA alkaline batteries |
Power supply | AC 220 V, 50 Hz |
Measuring range (NTU) | 0 to 100, 0 to 200 |
Minimum readout value (NTU) | 0.01, 0.1 |
Calibration point | 4 |
Sample volume | 5 to 10 ml |
Principle method | 90° scattered light |
Operating temperature | 5 to 40°C |
Working temperature | 5 to 40°C |
Light source | Infrared-emitting diode (850 nm λ) |
Detector | Silicon photodiode |
Error value | ± 6 % (± 2 % F.S) |
Zero drift | ± 0.5 % F.S. |
Reset functions | Yes |
Memory | Stores up to 20 sets data |
Output | |
Dimension | 370 × 260 × 150 mm |
Weight | 1.5 kg |
Power batteries | DC 1.5 V, 5 AA alkaline batteries |
Power supply | AC 220 V, 50 Hz |
Measuring range (NTU) | 0 to 100, 100 to 400 |
Minimum readout value (NTU) | 0.01, 0.1 |
Calibration point | 5 |
Sample volume | 5 to 10 ml |
Principle method | 90° scattered light |
Operating temperature | 5 to 40°C |
Working temperature | 5 to 40°C |
Light source | Infrared-emitting diode (850 nm λ) |
Detector | Silicon photodiode |
Error value | ± 6 % (± 2 % F.S) |
Zero drift | ± 0.5 % F.S. |
Reset functions | Yes |
Memory | Stores up to 20 sets data |
Output | |
Dimension | 370 × 260 × 150 mm |
Weight | 1.5 kg |
Power batteries | DC 1.5 V, 5 AA alkaline batteries |
Power supply | AC 220 V, 50 Hz |
pH Mode | pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
ORP Mode | |
mV Mode | mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point |
Ion Mode | |
Water Hardness Mode | |
Temperature Mode | |
Conductivity Mode | Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C |
TDS Mode | TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS Accuracy ± 1 % F.S. TDS Factor 0.1 to 1.0 (default 0.5) |
Salinity Mode | |
Resistivity Mode | |
Dissolved Oxygen Mode | |
Temperature Range | 0 to 105°C, 32 to 221°F |
Temperature Accuracy | ± 0.5°C |
Temperature Resolution | 0.1°C |
Temperature Calibrations Points | 1 Point |
Temperature Compensation Mode | Manual or Automatic |
Data Hold Function | Manual or Automatic Endpoint Detection |
Stability Criteria | Low or High |
Calibration Due Alarm | 1 to 31 Days |
Reset Function | Yes |
Memory | Stores Up to 500 data sets |
Output | USB interface |
Connector | BNC, 6-pin mini plug |
Display | LCD |
Power supply | DC5 V, AC 220 V, 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
pH Mode | pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
ORP Mode | |
mV Mode | mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point |
Ion Mode | |
Water Hardness Mode | |
Temperature Mode | |
Conductivity Mode | Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C |
TDS Mode | TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS Accuracy ± 1 % F.S. TDS Factor 0.1 to 1.0 (default 0.5) |
Salinity Mode | Salinity Range 0 to 10 ppt (maximum 80 ppt) Salinity Accuracy ± 1 % F.S. Measurement modes Seawater or practical salinity |
Resistivity Mode | Resistivity Range 0 to 100 MΩ Resistivity Accuracy ± 1 % F.S. Resistivity Resolution 0.01, 0.1, 1 |
Dissolved Oxygen Mode | |
Temperature Range | 0 to 105°C, 32 to 221°F |
Temperature Accuracy | ± 0.5°C |
Temperature Resolution | 0.1°C |
Temperature Calibrations Points | 1 Point |
Temperature Compensation Mode | Manual or Automatic |
Data Hold Function | Manual or Automatic Endpoint Detection |
Stability Criteria | Low or High |
Calibration Due Alarm | 1 to 31 Days |
Reset Function | Yes |
Memory | Stores Up to 500 data sets |
Output | USB interface |
Connector | BNC, 6-pin mini plug |
Display | LCD |
Power supply | DC5 V, AC 220 V, 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
pH Mode | pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
ORP Mode | |
mV Mode | mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point |
Ion Mode | |
Water Hardness Mode | |
Temperature Mode | |
Conductivity Mode | Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C |
TDS Mode | |
Salinity Mode | |
Resistivity Mode | |
Dissolved Oxygen Mode | Dissolved Oxygen Range 0.00 to 20.00 mg/ L Dissolved Oxygen Accuracy ± 0.2 mg/ L Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable Dissolved Oxygen Calibration Points 1 or 2 Points % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg Salinity correction 0 to 50 g/ L |
Temperature Range | 0 to 105°C, 32 to 221°F |
Temperature Accuracy | ± 0.5°C |
Temperature Resolution | 0.1°C |
Temperature Calibrations Points | 1 Point |
Temperature Compensation Mode | Manual or Automatic |
Data Hold Function | Manual or Automatic Endpoint Detection |
Stability Criteria | Low or High |
Calibration Due Alarm | 1 to 31 Days |
Reset Function | Yes |
Memory | Stores Up to 500 data sets |
Output | USB interface |
Connector | BNC, 6-pin mini plug |
Display | LCD |
Power supply | DC5 V, AC 220 V, 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
pH Mode | pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
ORP Mode | mV Range ± 2000 mV mV Accuracy ± 0.2 mV mV Resolution 0.1 mV, selectable mV Calibration Points 1 Point, only for relative mode |
mV Mode | |
Ion Mode | Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Ion measurement resolution 0.001/0.01/0.1/1 Ion measurement calibration points 2 to 5 points Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction |
Water Hardness Mode | Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3) Water hardness measurement accuracy ±1% F.S Water hardness measurement resolution 0.001/0.01/0.1/1 Water hardness calibration points 2 to 5 points Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L |
Temperature Mode | Temperature measurement range 0 to 105°, 32 to 212°F Temperature measurement accuracy ± 0.5°C, ± 0.9°F Temperature measurement resolution 0.1°C, 0.1°F Temperature measurement calibration points 1 point |
Conductivity Mode | |
TDS Mode | |
Salinity Mode | |
Resistivity Mode | |
Dissolved Oxygen Mode | |
Temperature Range | 0 to 100°C, 32 to 221°F |
Temperature Accuracy | |
Temperature Resolution | |
Temperature Calibrations Points | |
Temperature Compensation Mode | Manual or Automatic |
Data Hold Function | Manual or Automatic end point detection |
Stability Criteria | Standard or high accuracy |
Calibration Due Alarm | 1 to 31 days |
Reset Function | Yes |
Memory | Stores up to 1000 sets data |
Output | USB communication interface |
Connector | BNC Connector |
Display | 7 inch TFT LCD display |
Power supply | DC 12 V, AC adapter, AC 220 V, 50 Hz |
Dimension (L × W × H) | 240 × 220 × 80 mm |
Weight | 1.7 kg |
Conductivity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient | Linear | ||||||||||
Reference temperature | 25 °C | ||||||||||
Stability conditions | Low or high | ||||||||||
Cell constant | K= 0.1, 1, 10 or custom | ||||||||||
Calibration due | 1 to 31 days or off | ||||||||||
Memory | 100 data sets | ||||||||||
Data hold | Manual or auto-end point | ||||||||||
Connector | 6 pin mini plug | ||||||||||
Power Control | Manual or Automatic (10, 20 or 30 minutes after last key pressed) | ||||||||||
Power | 3 × 1.5 V AA batteries or DC 5 V power adapter | ||||||||||
Dimension (L × W × H) | 170 × 85 × 30 mm | ||||||||||
Weight | 300 g |
Conductivity |
|
||||||||||
TDS |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient | Linear and Pure water compensation | ||||||||||
Reference temperature | 20 °C or 25 °C | ||||||||||
Stability conditions | Low or high | ||||||||||
Cell constant | K= 0.1, 1, 10 or custom | ||||||||||
Calibration due | 1 to 31 days or off | ||||||||||
Memory | 500 data sets | ||||||||||
Data hold | Manual or auto-end point | ||||||||||
Connector | 6 pin mini plug | ||||||||||
Power Control | Manual or Automatic (10, 20 or 30 minutes after last key pressed) | ||||||||||
Power | 3 × 1.5 V AA batteries or DC 5 V power adapter | ||||||||||
Dimension (L × W × H) | 170 × 85 × 30 mm | ||||||||||
Weight | 300 g |
Conductivity |
|
||||||||||
Salinity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient | Linear and Pure water compensation | ||||||||||
Reference temperature | 20 °C or 25 °C | ||||||||||
Stability conditions | Low or high | ||||||||||
Cell constant | K= 0.1, 1, 10 or custom | ||||||||||
Calibration due | 1 to 31 days or off | ||||||||||
Memory | 500 data sets | ||||||||||
Data hold | Manual or auto-end point | ||||||||||
Connector | 6 pin mini plug | ||||||||||
Power Control | Manual or Automatic (10, 20 or 30 minutes after last key pressed) | ||||||||||
Power | 3 × 1.5 V AA batteries or DC 5 V power adapter | ||||||||||
Dimension (L × W × H) | 170 × 85 × 30 mm | ||||||||||
Weight | 300 g |
Conductivity |
|
||||||||||
TDS |
|
||||||||||
Salinity |
|
||||||||||
Resistivity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient | Linear and Pure water compensation | ||||||||||
Reference temperature | 20 °C or 25 °C | ||||||||||
Stability conditions | Low or high | ||||||||||
Cell constant | K= 0.1, 1, 10 or custom | ||||||||||
Calibration due | 1 to 31 days or off | ||||||||||
Memory | 500 data sets | ||||||||||
Data hold | Manual or auto-end point | ||||||||||
Connector | 6 pin mini plug | ||||||||||
Power Control | Manual or Automatic (10, 20 or 30 minutes after last key pressed) | ||||||||||
Power | 3 × 1.5 V AA batteries or DC 5 V power adapter | ||||||||||
Dimension (L × W × H) | 170 × 85 × 30 mm | ||||||||||
Weight | 300 g |
Range | 0 to 1.0 aw |
Resolution | 0 to 1.0 aw |
Accuracy | ± 0.02 aw |
Sensor | Nonconductive humidity sensor |
Sampling Time | 5 Minutes |
Display | 6 bit backlight LCD digital display, (3 bit humidity aw, 3 bit temperature display) |
Operating Temperature | 0 to 50˚C |
Condition Humidity | < 95 % RH |
Dimension | 275 × 230 × 150 mm |
Power Supply | 2 × 1.5V AAA (UM-4) Battery |
Weight | 1.5 kg |
Measuring range | Water activity 0 to 0.980 aw (no condensing ) |
Temperature range | 0 to 50°C |
Measurement accuracy | ± 0.015 aw |
Temperature accuracy | ± 0.5°C |
Repeatability | ≤ 0.015 aw |
Temperature coefficient | ≤ 0.0005/°C |
Measurement points | 1 |
Print method | Measurement of the end of print Real-time print |
Display | Large screen LCD |
Output mode | Micro printer |
Relative Humidity | 0 to 95 % RH |
Dimension | 320 × 120 × 340 mm |
Packaging dimension | 540 × 420 × 240 mm |
Power consumption | ≤15 W |
Power supply | 220 V AC± 10 % |
Weight | 11 kg |