Portable spectrophotometer LSP-A11 is adopted with every test calibration ETC technology, where the standard white boards included in the optical system for great accuracy of every measurement. Equipped with automatic gloss compensation technology to ensures the accuracy of the color measurement data for the surface of different gloss. The measurement of the color of the powder, granules & other materials can be done by adding the powder accessories to this spectrophotometer.
Specifications
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03 |
Sensor | Dual light path sensor array |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation angle | 2°/10° |
Measurement time interval | 0.5 seconds |
Measurement time | 2 seconds |
Measuring aperture | 8 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,
Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz), Metamerism index Milm, adhesive/changing Color fastness, ISO illuminance, 8 gloss |
Color matching system | Matches |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Battery capacity | Rechargeable, 20000 continuous tests, 7.4V/6000 mAh |
Data being displayed | SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB, Bluetooth |
Data storage | 100 test samples , 200 measurement records for each sample |
Display | True color TFT touch screen |
Light source longevity | 10 years, 3 million tests |
Dimension (L*W*H) | 181 × 73 × 112 mm |
Weight | 550 g |
Features
2.8 inch TFT touch screen
Built-in camera to view measured area
High capacity rechargeable lithium-ion battery
CLED light source for measurement accuracy
SCS system for measurement repeatability
Simultaneous measurement of SCI & SCE
Equipped with gloss compensation technology
USB & Bluetooth data transmission
Customized for PANTONE color matching technology
Large storage capacity
Connection to mini printer for printing
Applications
Portable spectrophotometer has applications in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.
Standard Accessories
Accessories No. | Name |
1 | Power cord |
2 | USB cable |
3 | Driving software |
4 | Color QC software |
5 | Black and white calibration tile |
Request Quote
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Double beam 1200 lines/mm |
Photometric Range | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Accuracy | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Repeatability | ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) |
Detector | Imported silicon photodiode |
Light source | Imported Deuterium and Tungsten lamp |
Stray light | ≤ 0.03 % T @ 220 nm, 360 nm |
Stability | ± 0.0003 A/h @ 500 nm |
Data Output Port | USB drive, USB host, RS232 |
Power supply | AC 220 V, 50 Hz or 110 V, 60 Hz |
Noise | 0.0005 A @ 500 nm |
Display | 10.1 inches TFT colored capacitive touch screen |
Baseline flatness | ± 0.002 A |
Printer port | Parallel port |
Work mode | T, A, C, E |
Scanning speed | Hi, Med, Low (Max. 3000 nm/min) |
Wavelength setting | Auto |
Cuvette holder | 10 mm single hole cell holder |
Dimension | 810 × 660 × 390 mm |
Gross weight | 27 kg |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Double beam 1200 lines/mm |
Photometric Range | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Accuracy | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Repeatability | ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) |
Detector | Imported silicon photodiode |
Light source | Imported Deuterium and Tungsten lamp |
Stray light | ≤ 0.03 % T @ 220 nm, 360 nm |
Stability | ± 0.0003 A/h @ 500 nm |
Data Output Port | USB drive, USB host, RS232 |
Power supply | AC 220 V, 50 Hz or 110 V, 60 Hz |
Noise | 0.0005 A @ 500 nm |
Display | 10.1 inches TFT colored capacitive touch screen |
Baseline flatness | ± 0.001 A |
Printer port | Parallel port |
Work mode | T, A, C, E |
Scanning speed | Hi, Med, Low (Max. 3000 nm/min) |
Wavelength setting | Auto |
Cuvette holder | 10 mm single hole cell holder |
Dimension | 810 × 660 × 390 mm |
Gross weight | 27 kg |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4/5 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Double beam 1200 lines/mm |
Photometric Range | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Accuracy | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Repeatability | ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) |
Detector | Imported silicon photodiode |
Light source | Imported Deuterium and Tungsten lamp |
Stray light | ≤ 0.03 % T @ 220 nm, 360 nm |
Stability | ± 0.0003 A/h @ 500 nm |
Data Output Port | USB drive, USB host, RS232 |
Power supply | AC 220 V, 50 Hz or 110 V, 60 Hz |
Noise | 0.0005 A @ 500 nm |
Display | 10.1 inches TFT colored capacitive touch screen |
Baseline flatness | ± 0.001 A |
Printer port | Parallel port |
Work mode | T, A, C, E |
Scanning speed | Hi, Med, Low (Max. 3000 nm/min) |
Wavelength setting | Auto |
Cuvette holder | 10 mm single hole cell holder |
Dimension | 880 × 690 × 520 mm |
Gross weight | 45 kg |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 nm adjustable |
Wavelength Accuracy | ± 0.3 nm |
Wavelength Repeatability | ≤ 0.1 nm |
Photometric Range | (-4) ~ 4 A |
Photometric Mode | T,A,C,E |
Photometric Accuracy | ± 0.3 % τ(0 - 100 % τ) ; ± 0.002 A (0 ~ 0.5 A) ; ± 0.003 A(0.5 A ~ 1 A) |
Photometric Repeatability | 0.15 % τ(0 -100 % τ); ± 0.001 A(0 ~ 0.5 A) ; ± 0.0015 A(0.5 A ~ 1 A) |
Transmittance accuracy | |
Transmittance repeatability | |
Detector | |
Light Source | |
Stray Light | ≤ 0.03 % τ (220 nm NaI, 340 nm NaNO2) |
Stability | |
Data Output Port | |
Power Requirement | AC 220 V / 50 Hz, 110 V / 60 Hz. |
Dimensions | 560 × 450 × 230 mm |
Noise | ± 0.0002A @500nm |
Weight | 28 kg |
Gross Weight | |
Net Weight | |
Power | 120 W |
Display LCD | 6 inches blue LCD |
Optical System | Double beam |
Baseline Linearity | |
Baseline Drift | |
Baseline Flatness | ± 0.001 A |
Printer Port | |
Packing Size | |
Software | |
Packing Weight |
Cuvette | |
Temperature | |
PC | |
Wavelength range | 200 - 800 nm |
Path length | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | ≤ 3 nm (FWHM at Hg 546 nm) |
Path length of cuvette | |
Minimum Sample size | 0.5 - 2.0 µl |
Absorbance range | 0.02 - 90 A (10mm equivalent) |
Precision of wavelength | |
Absorbance precision | 0.003 Abs |
Absorbance accuracy | 1 % ( 7.332 Abs at 260 nm) |
Light source | Xenon flash lamp |
Measurement time | < 8 s |
Operating Voltage | 24 V DC |
Sample Pedestal Material | Aluminum alloy and Quartz fiber |
Detector Type | 3864-element linear silicon CCD array |
Screen | |
Software Compatibility | Windows 7, Windows XP |
Detects nucleic acid up to | 2 - 4500 ng/µL (dsDNA) |
Detects protein up to | |
Data Output | |
Operating Power Consumption | 20 W |
Standby Power Consumption | 5 W |
Dimension | 200 x 250 x 166 mm |
Weight | 2.6 kg |
Cuvette | |
Temperature | |
PC | |
Wavelength range | 200 - 850 nm |
Path length | 1 mm, 2 mm, 5 mm, 10 mm |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
Path length of cuvette | |
Minimum Sample size | 0.3 - 2.0 µl |
Absorbance range | 0.00 2 ~ 75 A (150, 300 optional, 10mm equivalent absorbance) |
Precision of wavelength | |
Absorbance precision | 0.002 Abs |
Absorbance accuracy | 1 % (0.76 absorbance at 350 nm) |
Light source | Xenon flash lamp |
Measurement time | < 5 s |
Operating Voltage | |
Sample Pedestal Material | |
Detector Type | 2048-element linear silicon CCD |
Screen | |
Software Compatibility | |
Detects nucleic acid up to | 4 - 3750 ng/µL (7500,15000 optional, dsDNA) |
Detects protein up to | 0.01 - 100 mg/mL (200, 400 optional, BSA) |
Data Output | |
Operating Power Consumption | |
Standby Power Consumption | |
Dimension | 240 x 210 x 110 mm |
Weight | 1.92 kg |
Cuvette | |
Temperature | |
PC | |
Wavelength range | 230 nm, 260 nm, 280 nm |
Path length | 1.0 mm, 0.2 mm |
Wavelength accuracy | |
Wavelength Resolution | |
Path length of cuvette | |
Minimum Sample size | 0.3 - 2.0 µl |
Absorbance range | 0.2 - 75A (10 mm equivalent absorbance) |
Precision of wavelength | |
Absorbance precision | 0.002 Abs |
Absorbance accuracy | 0.01 |
Light source | Xenon flash lamp |
Measurement time | < 5 s |
Operating Voltage | |
Sample Pedestal Material | |
Detector Type | |
Screen | |
Software Compatibility | |
Detects nucleic acid up to | 10 - 3750 ng/µL (dsDNA) |
Detects protein up to | 0.5 - 110 mg/mL (BSA) |
Data Output | |
Operating Power Consumption | |
Standby Power Consumption | |
Dimension | 240 x 220 x 140 mm |
Weight | 2.35 kg |
Cuvette | No |
Temperature | |
PC | Inbuilt |
Wavelength range | 190 - 850 nm |
Path length | 1 mm, 0.2 mm ,0.04 mm |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
Path length of cuvette | NA |
Minimum Sample size | 0.3 - 2.0 µl |
Absorbance range | 0 to 500 Abs |
Precision of wavelength | ± 1 nm |
Absorbance precision | 0.002 ~ 400 Abs (10 mm) |
Absorbance accuracy | 1 % (0.76 absorbance at 350 nm) |
Light source | Xenon flash lamp |
Measurement time | < 5 s |
Operating Voltage | |
Sample Pedestal Material | Stainless steel and quartz fiber |
Detector Type | 2048-element linear silicon CCD |
Screen | Color LCD Touchscreen display |
Software Compatibility | Win7 (64-bit operating system)/Win 8 |
Detects nucleic acid up to | 0.4 ~ 19000 ng/µL (dsDNA) |
Detects protein up to | 0.01 ~ 400 mg/mL (BSA) |
Data Output | |
Operating Power Consumption | |
Standby Power Consumption | |
Dimension | 350 x 240 x 220 mm |
Weight | 5.2 kg |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Single beam 1200 lines/mm |
Photometric Range | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Accuracy | 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) |
Photometric Repeatability | ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) |
Detector | Imported silicon photodiode |
Light source | Imported Deuterium and Tungsten lamp |
Stray light | ≤ 0.03 % T @ 220 nm, 360 nm |
Stability | ± 0.0005 A/h @ 500 nm |
Data Output Port | USB drive, USB host, RS232 |
Power supply | AC 220 V, 50 Hz or 110 V, 60 Hz |
Noise | 0.0005 A @ 500 nm |
Display | 10.1 inches TFT colored capacitive touch screen |
Baseline flatness | ± 0.002 A |
Printer port | Parallel port |
Work mode | T, A, C, E |
Scanning speed | Hi, Med, Low (Max. 3000 nm/min) |
Wavelength setting | Auto |
Cuvette holder | 10 mm manual 4 cell holder |
Dimension | 810 × 660 × 390 mm |
Gross weight | 27 kg |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Single beam 1200 lines/mm |
Photometric Range | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Accuracy | 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) |
Photometric Repeatability | ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) |
Detector | Imported silicon photodiode |
Light source | Imported Deuterium and Tungsten lamp |
Stray light | ≤ 0.03 % T @ 220 nm, 360 nm |
Stability | ± 0.0005 A/h @ 500 nm |
Data Output Port | USB drive, USB host, RS232 |
Power supply | AC 220 V, 50 Hz or 110 V, 60 Hz |
Noise | 0.0005 A @ 500 nm |
Display | 10.1 inches TFT colored capacitive touch screen |
Baseline flatness | ± 0.001 A |
Printer port | Parallel port |
Work mode | T, A, C, E |
Scanning speed | Hi, Med, Low (Max. 3000 nm/min) |
Wavelength setting | Auto |
Cuvette holder | 10 mm manual 4 cell holder |
Dimension | 810 × 660 × 390 mm |
Gross weight | 27 kg |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4/5 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Single beam 1200 lines/mm |
Photometric Range | 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) |
Photometric Accuracy | 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) |
Photometric Repeatability | ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) |
Detector | Imported silicon photodiode |
Light source | Imported Deuterium and Tungsten lamp |
Stray light | ≤ 0.03 % T @ 220 nm, 360 nm |
Stability | ± 0.0005 A/h @ 500 nm |
Data Output Port | USB drive, USB host, RS232 |
Power supply | AC 220 V, 50 Hz or 110 V, 60 Hz |
Noise | 0.0005 A @ 500 nm |
Display | 10.1 inches TFT colored capacitive touch screen |
Baseline flatness | ± 0.001 A |
Printer port | Parallel port |
Work mode | T, A, C, E |
Scanning speed | Hi, Med, Low (Max. 3000 nm/min) |
Wavelength setting | Auto |
Cuvette holder | 10 mm manual 4 cell holder |
Dimension | 810 × 660 × 390 mm |
Gross weight | 27 kg |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 1 nm |
Wavelength Accuracy | ± 0.3 nm |
Wavelength Repeatability | 0.2 nm |
Photometric Range | 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C |
Photometric Mode | |
Photometric Accuracy | ± 0.3 % T |
Photometric Repeatability | 0.2 % T |
Transmittance accuracy | |
Transmittance repeatability | |
Detector | Silicon Photodiode |
Light Source | Deuterium & Tungsten Halogen Lamp |
Stray Light | ≤ 0.05 % T at 220 nm, 360 nm |
Stability | 0.002 A / h at 500 nm |
Data Output Port | USB |
Power Requirement | AC 220 V / 50 Hz, 110 V / 60 Hz. |
Dimensions | |
Noise | ± 0.001 A |
Weight | |
Gross Weight | |
Net Weight | |
Power | |
Display LCD | |
Optical System | Single Beam (1200 lines / mm grating) |
Baseline Linearity | |
Baseline Drift | |
Baseline Flatness | ± 0.001 A |
Printer Port | Parallel Port |
Packing Size | 860 x 660 x 465 mm |
Software | |
Packing Weight | 35 kg |
Wavelength Range | 330 to 1000 nm |
Setting Wavelength | |
Spectral Bandwidth | 5 nm |
Wavelength Accuracy | ± 2 nm |
Wavelength Repeatability | ≤ 1.0 nm |
Photometric Range | T: 0 to199.9%, A: -0.3 to2.5 Abs, F; 0 to 9999, C: 0 to 9999 |
Photometric Mode | |
Photometric Accuracy | ± 0.5 % T |
Photometric Repeatability | ≤ 0.2 % T |
Transmittance accuracy | |
Transmittance repeatability | |
Detector | Silicone photo diode |
Light Source | 20 W, 12 V Tungsten lamp |
Stray Light | ≤ 0.5 % T (360 nm) |
Stability | Dark current: ≤ 0.2 % T, Light Current: ≤ 0.5 % T |
Data Output Port | |
Power Requirement | 220 V ± 20 V, 50 Hz ± 1 Hz |
Dimensions | 470 × 350 × 200 mm |
Noise | |
Weight | 8 kg |
Gross Weight | |
Net Weight | |
Power | |
Display LCD | |
Optical System | Single beam, C-T grating monochromator 1200 lines/ mm |
Baseline Linearity | |
Baseline Drift | |
Baseline Flatness | |
Printer Port | |
Packing Size | |
Software | |
Packing Weight |
Wavelength Range | 335 ~ 1000 nm |
Setting Wavelength | |
Spectral Bandwidth | 4 nm |
Wavelength Accuracy | ± 2 nm |
Wavelength Repeatability | 1 nm |
Photometric Range | T: 0 ~ 199.9 % , A: (-0.3) ~ 2.5A bs, F: 0 ~ 9999, C: 0 ~ 9999 |
Photometric Mode | |
Photometric Accuracy | ± 0.5 % T |
Photometric Repeatability | 0.2 % T |
Transmittance accuracy | |
Transmittance repeatability | |
Detector | Silicon photo diode |
Light Source | Tungsten lamp (Socket Type, 20W / 12V, 2000h) |
Stray Light | ≤ 0.5 % T (360 nm) |
Stability | ≤ 0.5 % T / 5min |
Data Output Port | |
Power Requirement | 220 V / 50 Hz |
Dimensions | 385 × 330 × 185 mm |
Noise | |
Weight | 10 kg |
Gross Weight | |
Net Weight | |
Power | |
Display LCD | |
Optical System | 1200 lines / mm grating |
Baseline Linearity | |
Baseline Drift | |
Baseline Flatness | |
Printer Port | |
Packing Size | |
Software | |
Packing Weight |
Wavelength Range | 325 ~ 1000 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 1.0 nm |
Wavelength Repeatability | ≤ 0.2 nm |
Photometric Range | (-0.3) ~ 3 A |
Photometric Mode | |
Photometric Accuracy | ± 0.3 % T |
Photometric Repeatability | 0.15 % τ |
Transmittance accuracy | |
Transmittance repeatability | |
Detector | Import Silicon Photodiode Detector |
Light Source | Import Tungsten Lamp |
Stray Light | ≤ 0.05 % τ |
Stability | 0.001 A / h at 500 nm |
Data Output Port | |
Power Requirement | AC 220 V / 50 Hz, 110 V / 60 Hz. |
Dimensions | 460 × 330 × 210 mm |
Noise | |
Weight | 11 kg |
Gross Weight | |
Net Weight | |
Power | 120 W |
Display LCD | |
Optical System | |
Baseline Linearity | |
Baseline Drift | |
Baseline Flatness | |
Printer Port | |
Packing Size | |
Software | |
Packing Weight |
Wavelength Range | 320 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 4 nm |
Wavelength Accuracy | ± 0.5 nm |
Wavelength Repeatability | ≤ 0.2 nm |
Photometric Range | (-0.3) ~ 3 A |
Photometric Mode | |
Photometric Accuracy | ± 0.3 % T |
Photometric Repeatability | 0.15 % τ |
Transmittance accuracy | |
Transmittance repeatability | |
Detector | Import Silicon Photodiode Detector |
Light Source | Import Tungsten Lamp |
Stray Light | ≤ 0.05 % τ |
Stability | 0.001 A / h 30 min at 500 nm |
Data Output Port | |
Power Requirement | AC 220 V / 50 Hz, 110 V / 60 Hz. |
Dimensions | 480 × 350 × 220 mm |
Noise | |
Weight | 11 kg |
Gross Weight | |
Net Weight | |
Power | 120 W |
Display LCD | Display resolution 128 × 64 Dots LCD |
Optical System | |
Baseline Linearity | |
Baseline Drift | |
Baseline Flatness | |
Printer Port | |
Packing Size | |
Software | |
Packing Weight |
Working spectral range | 190 to 900 nm |
Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
Wavelength accuracy | ± 0.15 nm |
Wavelength repeatability | ≤ 0.04 nm |
Baseline stability | ≤ 0.002 Abs / 30 min |
Characteristic concentration of copper | 0.02 μg / ml / 1 % |
Detection limit of copper | 0.004 μg / ml |
Measurement Repeatability | 0.005 |
Grating | 1800 lines / mm |
Inflamer | All-metal titanium burner |
Atomizer | Efficient glass atomizer |
Lamp stand | 8 lamps automatic turret, automatic alignment |
D2 Background calibration ability | 1 A ≤ 30 times correction ability |
Dimensions | 700 × 550 × 450 mm |
Net weight | 75 Kg |
Power supply | 220 V ± 22 V AC |
Acetylene air burner | 100 mm |
Ignition dynamic baseline drift | ≤ 0.006 Abs / 30 min |
Characteristic viscocity | ≤ 0.025 μg / ml / 1 % |
Standard deviation of the accuracy | ≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml) |
Protection system | Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner |
Monochromator | |
Wavelength range | 190 - 900 nm |
Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
Wavelength accuracy | ≤ ± 0.5 nm |
Wavelength repeatability | ≤ 0.3 nm(single direction) |
Baseline drift | ± 0.004 Abs / 30 min |
Grating groove density | |
Sample Volume | |
The volume of sample | |
Repeated Sampling Frequency | |
Cleaning and waste container volume | |
Absorbance Range | |
The Program | |
Temperature Range | |
Detector | |
Heating Mode | |
Temperature Control Method | |
Temperature Control | |
Resolution | < 40 % |
Lamp holder | |
Lamp current adjustment range | |
Lamp power supply mode | |
Optical System | |
Atomization Chamber | |
Characteristics Volume | |
Characteristic concentration (Cu) | ≤ 0.04 mg / ml / 1 % |
Detection Limit | |
Detection Limit (Cu) | 0.008 mg/ml |
Background calibration ability | Greater than 30 times |
Burner | |
Nebulizer | |
Precision | |
Ignition Type | |
Sprayer | |
Room Spray | |
Sample Tray | |
The Smallest Lincrement | |
Safety measures | |
Gas Control | |
Measurement | |
Concentration calculation | |
The Cooling Water | |
The number of repeated measurements | |
Print results | |
Software Environment | |
Operating temperature | |
Working humidity | |
Power supply | 220 V / 3 A, 50 Hz |
Power (VAC) | |
Gross Weight | 160 kg |
Weight | |
Dimension (L × W × H) | 1220 x 770 x 730 mm |
Monochromator | |
Wavelength range | 180 - 900 nm |
Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
Wavelength accuracy | ≤ 0.15 nm |
Wavelength repeatability | ± 0.1 nm |
Baseline drift | ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic) |
Grating groove density | |
Sample Volume | |
The volume of sample | |
Repeated Sampling Frequency | |
Cleaning and waste container volume | |
Absorbance Range | 0 - 4 A |
The Program | |
Temperature Range | |
Detector | Imported photomultiplier tube |
Heating Mode | |
Temperature Control Method | |
Temperature Control | |
Resolution | |
Lamp holder | ≤ 6 lamps automatic turret, automatic alignment |
Lamp current adjustment range | |
Lamp power supply mode | pulsed power supply |
Optical System | large 1800 /mm grating ruling, full closed optical system |
Atomization Chamber | Polymer explosion-proof spray chamber |
Characteristics Volume | |
Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
Detection Limit | |
Detection Limit (Cu) | 0.002 μg/mL |
Background calibration ability | |
Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
Nebulizer | Atomizer efficient glass atomizer,can also be customized |
Precision | RSD ≤ 0.5 % |
Ignition Type | Microcomputer control, automatic ignition |
Sprayer | |
Room Spray | |
Sample Tray | |
The Smallest Lincrement | |
Safety measures | |
Gas Control | Automatic gas control system |
Measurement | Flame method, Hydride generation-Atomic absorption method |
Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
The Cooling Water | |
The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
Software Environment | |
Operating temperature | |
Working humidity | |
Power supply | 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA |
Power (VAC) | |
Gross Weight | |
Weight | |
Dimension (L × W × H) |
Monochromator | |
Wavelength range | 180 – 900 nm |
Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) |
Wavelength accuracy | ≤ 0.15 nm |
Wavelength repeatability | ± 0.1 nm |
Baseline drift | ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic) |
Grating groove density | |
Sample Volume | |
The volume of sample | |
Repeated Sampling Frequency | |
Cleaning and waste container volume | |
Absorbance Range | 0 - 4 A |
The Program | |
Temperature Range | |
Detector | |
Heating Mode | |
Temperature Control Method | |
Temperature Control | |
Resolution | |
Lamp holder | ≤ 3 lamps automatic turret, automatic alignment |
Lamp current adjustment range | |
Lamp power supply mode | pulsed power supply |
Optical System | large 1800 /mm grating ruling, full closed optical system |
Atomization Chamber | Polymer explosion-proof spray chamber |
Characteristics Volume | |
Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
Detection Limit | |
Detection Limit (Cu) | 0.002 μg/mL |
Background calibration ability | |
Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
Nebulizer | Atomizer efficient glass atomizer,can also be customized |
Precision | RSD ≤ 0.5 % |
Ignition Type | Microcomputer control, automatic ignition |
Sprayer | |
Room Spray | |
Sample Tray | |
The Smallest Lincrement | |
Safety measures | |
Gas Control | Automatic gas control system |
Measurement | Flame method, Hydride generation-Atomic absorption method |
Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
The Cooling Water | |
The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
Software Environment | |
Operating temperature | |
Working humidity | |
Power supply | |
Power (VAC) | |
Gross Weight | |
Weight | |
Dimension (L × W × H) |
Wavelength Range | 400 nm to 700 nm |
Wavelength Interval | 10 nm |
Sensor | High sensitivity silicon photodiode |
Light Source | LED |
Working Temperature Range | 0 ℃ to 45 ℃ |
Measurement Aperture | 11 mm |
Geometry | 45/0 (45 ringed shaped illumination, 0 degree viewing) |
Observer Viewing Angles | 2°/ 10° |
Repeatability | Standard deviation within 0.08% Chromaticity Value; ΔE*ab |
Inter-Instrument Agreement | ΔE*ab within 0.2 (BCRA Series II, average measurement of the 12 tiles) |
Illuminants | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30.DLF,NBF,TL83,TL84.U35 |
Color Spaces | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance Hunter lab, Munsell MI,CMYK,RGB,HSB |
Color Difference | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 shade sort |
Other Indices | WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby); YI(ASTM D1925, ASTM E313-00,ASTM E313-73); Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness ISO Brightness, 8 gloss, A density, T density, M density, E density |
Standards | CIE-15-2004; ASTM-D523; ASTM-D2244; ASTM D2457 |
Illumination Life time | 10 years 3 million test |
Interface | USB |
Screen Size | 5 Inches Color Screen |
Storage Memory | 20000 test results |
Battery Capacity | Rechargeable, 1000 continuous tests |
Power | 7.4 V/ 6000 mAh |
Dimensions (L × W × H) | 350 × 300 × 200 mm |
Weight | 4.5 kg (without battery) |
Wavelength Range | 360 nm to 780 nm |
Wavelength Pitch | 10 nm |
Sensor | Silicon Photodiode Array |
Grating Method | Concave Grating |
Sphere Diameter | 152 mm |
Half Band Width | 5 nm |
Reflectance Range | 0 to 200 % |
Resolution | 0.0001 |
Light Source | Pulse Xenon Lamp LED |
UV Measurement | Include UV, 400nm cut, 420nm cut, 460nm cut |
Operating Temperature | 5 ℃ to 40 ℃ |
Storage Temperature | -20 ℃ to 45 ℃ |
Relative Humidity | 80 % RH (at 35 ℃) |
Measurement Time | SCI/SCE < 2 SCI+SCE < 4s |
Measurement Aperture | Reflectance: XLAV Φ30mm LAV 18mm,MAV Φ11mm SAV Φ6mm Transmittance:Φ25mm (Auto aperture size recognition) |
Viewing Angles | 2° and 10° |
Transmittance Sample Size | No limit on sample width and height Thickness ≤ 50mm |
Repeatability | XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1% XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration |
Inter-Instrument Agreement | XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃) |
Illuminants | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 |
Display | Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency |
Color Spaces | L*a*b, L*C*h, Hunter Lab, Yxy, XYZ |
Color Difference | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort |
Other Indices | WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength |
Other Functions | 1. Camera to view measurement area 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement) 3. Auto humidity and temperature compensation function |
Illumination/ Viewing System | Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing ) |
Interface | USB USB-B RS-232 |
Screen Size | 7 Inches Touch Screen |
Storage Memory | 8 GB U Disk for data storage and transfer |
Power | 12V/3A |
Dimensions (L × W × H) | 430 × 240 × 260 mm |
Weight | 10.8 kg |
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Sensor | Dual light path sensor array |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation Angle | 2°/10° |
Measurement caliber | |
Measurement time interval | 0.5 s |
Measurement time | 1 s |
Measuring aperture | 11 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73) Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density |
Repeatability | light splitting reflectivity:standard deviation within 0.08% color values:ΔE*ab |
Color matching system | Matches |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Battery capacity | Rechargeable, 20000 continuous tests, 7.4V/6000mAh |
Data being displayed | SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB |
Display | 5.5 inch TFT touch screen |
Data storage | 20000 test results |
Light source longevity | 10 years, 3 million tests |
Dimension (L*W*H) | 350 × 300 × 200 mm |
Weight | 4.5 kg |
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Sensor | Dual light path sensor array |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation Angle | 2°/10° |
Measurement caliber | |
Measurement time interval | 0.5 s |
Measurement time | 1 s |
Measuring aperture | 11 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73) Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density |
Repeatability | light splitting reflectivity:standard deviation within 0.08% color values:ΔE*ab |
Color matching system | Matches |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Battery capacity | Rechargeable, 20000 continuous tests, 7.4V/6000mAh |
Data being displayed | SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB |
Display | 5.5 inch TFT touch screen |
Data storage | 20000 test results |
Light source longevity | 10 years, 3 million tests |
Dimension (L*W*H) | 350 × 300 × 200 mm |
Weight | 4.5 kg |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab |
Sensor | High sensitivity silicon photodiode |
Test angle | - |
Test area | - |
Test range | - |
Test repeatability | - |
Reproducibility | - |
Inter instrument agreement | 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles) |
Illumination light source | LED |
Light source | A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35 |
Wavelength range | 400 nm to 700 nm |
Wavelength interval | 10 nm |
Observation angle | 2°/10° |
Measuring aperture | 11 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK |
Color difference formula | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density. |
Color matching system | Not included |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Battery capacity | Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh |
Interface | USB |
Data storage | 20000 samples |
Display | True color TFT touch screen |
Light source longevity | 10 years, 3 million test |
Dimension | 181 × 73 × 112 mm |
Weight | 800 g (without battery) |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab |
Sensor | High sensitivity silicon photodiode |
Test angle | 60° |
Test area | 5 × 10 mm |
Test range | 0 to 1000 GU |
Test repeatability | 0.2 GU (0 to 100 GU), 0.2% (100 to 1000 GU) |
Reproducibility | 1.0 GU (0 to 100 GU), 1.0% (100 to 1000 GU) |
Inter instrument agreement | 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles) |
Illumination light source | LED |
Light source | A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35 |
Wavelength range | 400 nm to 700 nm |
Wavelength interval | 10 nm |
Observation angle | 2°/10° |
Measuring aperture | 11 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK |
Color difference formula | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density. |
Color matching system | Not included |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Battery capacity | Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh |
Interface | USB |
Data storage | 20000 samples |
Display | True color TFT touch screen |
Light source longevity | 10 years, 3 million test |
Dimension | 181 × 73 × 112 mm |
Weight | 800 g (without battery) |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab |
Sensor | Blue light enhanced sensor array |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation angle | 2°/10° |
Measurement time interval | 2 seconds |
Measurement time | 2 seconds |
Measuring aperture | 8 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance |
Color difference formula | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00 |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness |
Color matching system | Not match |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Battery capacity | Rechargeable, 10000 continuous tests, 7.4V/6000 mAh |
Data being displayed | SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB |
Data storage | 100 test samples , 200 measurement records for each sample |
Display | True color TFT touch screen |
Light source longevity | 5 years, 1.5 million tests |
Dimension (L*W*H) | 181 × 73 × 112 mm |
Weight | 550 g |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab |
Sensor | Photoelectric diode sensor |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation angle | 2°/10° |
Measurement time interval | 0.5 seconds |
Measurement time | 2 seconds |
Measuring aperture | 8 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Staining fastness, Color fastness |
Color matching system | Not match |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Battery capacity | Rechargeable, 10000 continuous tests, 7.4V/6000 mAh |
Data being displayed | SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB |
Data storage | 100 test samples , 200 measurement records for each sample |
Display | True color 2.8 inch TFT touch screen |
Light source longevity | 10 years, 3 million tests |
Dimension (L*W*H) | 181 × 73 × 112 mm |
Weight | 550 g |
Light source | 150 W Xenon lamp |
Excitation wavelength | 200 nm to 900 nm |
Emission wavelength | 200 nm to 900 nm |
Excitation slit | 2 nm, 5 nm, 10 nm, 20 nm |
Emission slit | 2 nm, 5 nm, 10 nm, 20 nm |
Wavelength accuracy | ±0.4 nm |
Wavelength repeatability | ≤ 0.2 nm |
Signal-to-Noise Ratio | Raman peak of water (P-P): S/N ≥ 200 (10 nm Slit) |
Detection limit | ≤5×10-11 g/ml (Quinine Sulphate Solution) |
Linearity | γ ≥ 0.995 |
Peak repeatability | ≤ 1.5% |
Stability (10 min) Zero Drift | ±0.3 |
Stability (10 min) Value Limit | ±1.5% |
Wavelength scan speed | Multi-speed level, Maximum at 48000 nm/min |
Photometric value | 0.00 to 10000.00 |
Data interface | USB 2.0 |
Maximum power consumption | 200 W |
Power Source | AC 220 V/50 Hz; 110 V/60 Hz |
Dimension | 380×445×310 mm |
Net weight | 12 kg |
Gross weight | 14 kg |
Light source | 150 W Xenon lamp |
Excitation wavelength | 200 nm to 900 nm |
Emission wavelength | 200 nm to 900 nm |
Excitation slit | 2 nm, 5 nm, 10 nm, 20 nm |
Emission slit | 2 nm, 5 nm, 10 nm, 20 nm |
Wavelength accuracy | ±1.0 nm |
Wavelength repeatability | ≤ 0.5 nm |
Signal-to-Noise Ratio | Raman peak of water (P-P): S/N ≥ 150 (10 nm Slit) |
Detection limit | ≤1×10-10 g/ml (Quinine Sulphate Solution) |
Linearity | γ ≥ 0.995 |
Peak repeatability | ≤ 1.5% |
Stability (10 min) Zero Drift | ±0.3 |
Stability (10 min) Value Limit | ±1.5% |
Wavelength scan speed | Multi-speed level, Maximum at 48000 nm/min |
Photometric value | 0.00 to 10000.00 |
Data interface | USB 2.0 |
Maximum power consumption | 200 W |
Power Source | AC 220 V/50 Hz; 110 V/60 Hz |
Dimension | 380×445×310 mm |
Net weight | 12 kg |
Gross weight | 14 kg |
Excitation Source | 150 W Xenon Lamp |
Excitation Wavelength | 200 nm to 900 nm |
Excitation Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
Emission Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
Wavelength Accuracy | ± 0.4 nm |
Wavelength Repeatability | ≤ 0.2 nm |
Signal-to-Noise Ratio | S/N ≥ 350 (P-P), S/N ≥ 1000 (RMS) |
Limit | ≤ 5 × 10 -11 g /ml(Quinine Sulfate Solution) |
Linearity | γ ≥ 0.995 |
Peak Repeatability | ≤ 1.5 % |
Wavelength Scan Speed | Multi-speed Level, Maximum at 60000 nm / min |
Minimum sample size | 0.5 mL (Using a standard 10 mm square sample cell) |
Octave filter | Build in Octave filter |
Photometric Quantity Range | -9999 to 9999 |
Response Time | Auto adjust (0.02 s, 0.1 s, 0.5 s, 1 s, 2 s, 4 s, 8 s ) |
Data Transportation | USB 2.0 |
Power | 200 W |
Power Supply | AC 220 V / 50 Hz, 110 V / 60 Hz |
Dimension | 610×460×365 mm |
Net Weight | 21 kg |
Gross Weight | 26 kg |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Photometric Accuracy | 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A) |
Photometric Repeatability | ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A) |
Photometric Range | 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F) |
Stray Light | ≤ 0.03 % T @ 22 nm, 360 nm |
Stability | ± 0.0005 A/h @500 nm |
Baseline Flatness | ± 0.002 A |
Noise | 0.0005 A @ 500 nm |
Work Mode | T, A, C, E |
Scanning Speed | High, Medium, Low ( Max 3000 nm/ min ) |
Wavelength Setting | Auto |
Display | 7 inch TFT Coloured Capacitive Touch Screen |
Light Source | Imported Xenon Lamp |
Detector | Imported Silicon Photodiode |
Cuvette Holder | 10 mm single hole cell holder |
Output | USB Drive, USB host, RS232 |
Power Supply | AC 220 V/ 500 Hz or AC 110 V / 60 Hz |
Packaging dimension | 810 × 660 × 390 mm |
Gross Weight | 27 kg |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Photometric Accuracy | 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A) |
Photometric Repeatability | ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A) |
Photometric Range | 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F) |
Stray Light | ≤ 0.03 % T @ 22 nm, 360 nm |
Stability | ± 0.0005 A/h @500 nm |
Baseline Flatness | ± 0.001 A |
Noise | 0.0005 A @ 500 nm |
Work Mode | T, A, C, E |
Scanning Speed | High, Medium, Low ( Max 3000 nm/ min ) |
Wavelength Setting | Auto |
Display | 7 inch TFT Coloured Capacitive Touch Screen |
Light Source | Imported Xenon Lamp |
Detector | Imported Silicon Photodiode |
Cuvette Holder | 10 mm single hole cell holder |
Output | USB Drive, USB host, RS232 |
Power Supply | AC 220 V/ 500 Hz or AC 110 V / 60 Hz |
Packaging dimension | 810 × 660 × 390 mm |
Gross Weight | 27 kg |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Photometric Accuracy | 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A) |
Photometric Repeatability | ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A) |
Photometric Range | 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F) |
Stray Light | ≤ 0.03 % T @ 22 nm, 360 nm |
Stability | ± 0.0003 A/h @500 nm |
Baseline Flatness | ± 0.002 A |
Noise | 0.0005 A @ 500 nm |
Work Mode | T, A, C, E |
Scanning Speed | High, Medium, Low ( Max 3000 nm/ min ) |
Wavelength Setting | Auto |
Display | 10.1inch TFT Coloured Capacitive Touch Screen |
Light Source | Imported Xenon Lamp |
Detector | Imported Silicon Photodiode |
Cuvette Holder | 10 mm single hole cell holder |
Output | USB Drive, USB host, RS232 |
Power Supply | AC 220 V/ 500 Hz or AC 110 V / 60 Hz |
Packaging dimension | 810 × 660 × 390 mm |
Gross Weight | 27 kg |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Photometric Accuracy | 0.2 % T (0 to 100%T), ± 0002 A (0-0.5A), ± 0.004A(0.5-1A) |
Photometric Repeatability | ≤ 0.15 % T ( 0-100 % T), 0.001A (0-0.5A), 0.002A(0.5-1A) |
Photometric Range | 0-200% T, -0.3 to 3A, 0-9999 C (0-9999 F) |
Stray Light | ≤ 0.03 % T @ 22 nm, 360 nm |
Stability | ± 0.0003 A/h @500 nm |
Baseline Flatness | ± 0.001 A |
Noise | 0.0005 A @ 500 nm |
Work Mode | T, A, C, E |
Scanning Speed | High, Medium, Low ( Max 3000 nm/ min ) |
Wavelength Setting | Auto |
Display | 10.1inch TFT Coloured Capacitive Touch Screen |
Light Source | Imported Xenon Lamp |
Detector | Imported Silicon Photodiode |
Cuvette Holder | 10 mm single hole cell holder |
Output | USB Drive, USB host, RS2 |
Power Supply | AC 220 V/ 500 Hz or AC 110 V / 60 Hz |
Packaging dimension | 810 × 660 × 390 mm |
Gross Weight | 27 kg |