A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 374

Backtrace:

File: /home/servetes/public_html/labtron.cc/application/helpers/common_helper.php
Line: 374
Function: _error_handler

File: /home/servetes/public_html/labtron.cc/application/controllers/Website.php
Line: 449
Function: generate_captcha

File: /home/servetes/public_html/labtron.cc/application/controllers/Website.php
Line: 64
Function: singlecatalog

File: /home/servetes/public_html/labtron.cc/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 378

Backtrace:

File: /home/servetes/public_html/labtron.cc/application/helpers/common_helper.php
Line: 378
Function: _error_handler

File: /home/servetes/public_html/labtron.cc/application/controllers/Website.php
Line: 449
Function: generate_captcha

File: /home/servetes/public_html/labtron.cc/application/controllers/Website.php
Line: 64
Function: singlecatalog

File: /home/servetes/public_html/labtron.cc/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 379

Backtrace:

File: /home/servetes/public_html/labtron.cc/application/helpers/common_helper.php
Line: 379
Function: _error_handler

File: /home/servetes/public_html/labtron.cc/application/controllers/Website.php
Line: 449
Function: generate_captcha

File: /home/servetes/public_html/labtron.cc/application/controllers/Website.php
Line: 64
Function: singlecatalog

File: /home/servetes/public_html/labtron.cc/index.php
Line: 318
Function: require_once

Biosafety Cabinet Class II B2 LBS2-B22 Catalog | Labtron

Ask An Expert

Biosafety Cabinet Class II B2 LBS2-B22 Catalog

Biosafety Cabinet Class II B2 LBS2-B22

Biosafety Cabinet Class II B2 LBS2-B22

Overview

Biosafety Cabinet Class II B2 LBS2-B22 is a Class II type B2 total exhaust cabinet with 420 mm (17 inch) maximum opening. It has ULPA Filter Two in number, 99.999 % efficient at 0.12 µm and offers two layer laminated toughened glass >5 mm. Designed with Large digital LCD display used to monitor all safety parameters and Universal caster for moving with brake and levelling feet. Work area surrounded by negative pressure and it can ensure maximum safety in work area.

Features

  • - Designed with ULPA filter and UV indicator
    Automatic air speed adjustable with filter block
    Large digital display used to monitor exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc
    Two layer laminated toughened glass >5 mm, anti UV
    Universal caster with brake and levelling feet
    Memory function in case of power-failure
    Equipped with Interlock function, UV lamp, front window, fluorescent lamp
    Designed with Remote control and Audio, visual alarm
    Time reserve function
    Motorized front window
    Maximum safety in work area surrounded by negative pressure
    Adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement
Specifications
Max Opening500 mm (20 inch)
Tested OpeningSafety Height 200 mm(8 inch)
Inflow Velocity0.53 ± 0.025 m/s
Down flow Velocity0.33 ± 0.025 m/s
Pre-FilterWashable
ULPA Filter99.999 % efficiency at 0.12 μm, filter life indicator
Front WindowMotorized, two-layer laminated toughened glass ≥ 5 mm, anti UV
NoiseNSF49 ≤ 61 dB / EN1246949 ≤ 58 dB 
Illumination≥ 1000 Lux
Consumption900 W
DisplayLCD display, exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.
Waterproof SocketsTwo, total load of two sockets 500 W
Control SystemMicroprocessor
Airflow System0 % air recirculation, 100 % air exhaust
AlarmAbnormal airflow velocity, Filter replacement, Front window at unsafe height
Exhaust Duct4 meters PVC duct, Diameter 300 mm
Material Work Zone304 stainless steel
Material Main BodyCold-rolled steel with anti-bacteria powder coating
Work Surface Height750 mm
CasterFoot master caster
UV Lamp30 W × 1 UV timer, UV life indicator, emission of 253.7 nano meters for most efficient decontamination
Illuminating LampLED Lamp 16 W × 2
Internal dimension (W×D×H)1350 × 600 × 660 mm
External dimension (W×D×H)1500 × 760 × 2250 mm
Power supplyAC 220V±10 %, 50/60 Hz; 110V±10 %, 60 Hz
Weight302 kg
Applications :

Biosafety Cabinet product is used in protection from biological hazards and contamination as well as protection from volatile toxic chemicals.

Applications :

Biosafety Cabinet product is used in protection from biological hazards and contamination as well as protection from volatile toxic chemicals.

Enquiry Now