Differential Scanning Calorimeter LDSC-A11

Differential Scanning Calorimeter LDSC-A11 is an analyzer which allows the measurement of different characteristic properties of various samples from RT to 600°C. It meets ASTM, ISO standards. High resolution, stable base line, air flow meter, bilateral control etc. are some of the features which ensures accurate and reliable results. It finds applications in fields like polymer development, quality control of different materials, performance testing and many other industries.

Specifications Features Applications Standard Accessories Get Quote View Catalog

Specifications

Temperature range RT to 600°C (Air cooled)
Temperature resolution 0.1°C
Temperature fluctuations ± 0.1°C
Temperature repeatability ± 0.1°C
Dynamic heat flow range (DSC range) 0 to ± 500 mW
Heating rate 1 to 80°C / min
Cooling rate 1 to 20°C / min
DSC noise 0.01 μW
DSC resolution 0.01 µW
DSC accuracy 0.1 µW
DSC sensitivity 0.1 µW
Control Mode Rising temperature, constant temperature (full automatic)
Curve scanning Rising scan, cooling scan
Gas flow control Embedded digital flow meter & Software control, automatic changing
Parameter standard With standard material, with calibration function, the user may correct temperature and heat enthalpy
Display 24 bit 7 inches LCD touch screen display
Data interface Standard USB connector
Power Consumption Less than 2000 W
Packaging Dimension and Gross weight (2 case) 580×490×520 mm / 29 kg
530×270×280 mm / 15 kg

Features

Renewed design of oven structure

High stability and resolution of base line

Accurate control of air flow rate

Test data storage function

Both main frame and software control option

LCD touch screen display

Meets ISO and ASTM standards

Applications

It is used to study thermal transitions, heat capacity, glass transition temperature, crystallinity, melting temperature etc. of various materials like polymers, plastics, elastomer, food stuffs, biomolecules, non-corrosive samples, electronic components etc.

Standard Accessories

Name of Accessories Quantity
Host instrument 1
CD 1
Data Line 1
Power Line 1
Aluminium crucibles 100
Ceramic crucibles 100
pure tin grains 1bag
Fuse 4A 5

Request Quote

Differential Scanning Calorimeters

Differential Scanning Calorimeter LDSC-A10

Temperature range RT to 800°C (Air cooled)
Temperature resolution 0.1°C
Temperature fluctuations ± 0.1°C
Temperature repeatability ± 0.1°C
Dynamic heat flow range (DSC range) 0 to ± 500 mW
Heating rate 1 to 80°C / min
Cooling rate 1 to 20°C / min (OPTIONAL)
DSC noise 0.01 μW
DSC resolution 0.01 µW
DSC accuracy 0.1 µW
DSC sensitivity 0.1 µW
Control Mode Rising temperature, constant temperature (full automatic)
Curve scanning Rising scan, cooling scan(OPTIONAL)
Gas flow control Embedded digital flow meter & Software control, automatic changing
Parameter standard With standard material, with calibration function, the user may correct temperature and heat enthalpy
Display 24 bit 7 inches LCD touch screen display
Data interface Standard USB connector
Power Consumption Less than 2000 W
Packaging Dimension and Gross weight (2 case) 580×490×520 mm / 29 kg 530×270×280 mm / 15 kg

Differential Scanning Calorimeter LDSC-A12

Temperature range -100°C to 800°C (Liquid nitrogen refrigeration)
Temperature resolution 0.1°C
Temperature fluctuations ± 0.1°C
Temperature repeatability ± 0.1°C
Dynamic heat flow range (DSC range) 0 to ± 500 mW
Heating rate 1 to 80°C / min
Cooling rate 1 to 20°C / min (OPTIONAL) (For instant cool only, cannot be Isothermal below RT, and if heating up, the rate can be controlled)
DSC noise 0.01 μW
DSC resolution 0.01 µW
DSC accuracy 0.1 µW
DSC sensitivity 0.1 µW
Control Mode Rising temperature, constant temperature (full automatic)
Curve scanning Rising scan, cooling scan(OPTIONAL)
Gas flow control Embedded digital flow meter & Software control, automatic changing
Parameter standard With standard material, with calibration function, the user may correct temperature and heat enthalpy
Display 24 bit 7 inches LCD touch screen display
Data interface Standard USB connector
Power Consumption Less than 2000 W
Packaging Dimension and Gross weight (2 case) 580×490×520 mm / 29 kg 530×270×280 mm / 15 kg