Ask An Expert
Halogen moisture analyzer LHMA-A12 with benchtop design, user can manually open the door of heating chamber for analysis. Incorporated with halogen heating lamp for rapid and uniform heating, it determines the moisture content and dry weight of the test sample. It continuously measures and immediately display the loss of moisture and weight on backlight LCD screen during test.
Used in biology, food, agriculture, pharmacy, textile, dye and research industries for determination of moisture content in the test sample.
| Range | 10 mg to 110 g |
| Readability | 10 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 5 mg to 110 g |
| Readability | 5 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 1 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 1 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-2 |
| Range | 4 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Cable |
| Range | 4 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Wireless |
| Range | 4 mg to 210 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Cable |
| Range | 4 mg to 210 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Wireless |
| Measuring Element | Grain |
| Moisture Range | 3 % to 35 % |
| Repeating Error | ≤ 0.2 % |
| Measuring Error | ≤ ± 0.5 % |
| Measuring grains | 25 types |
| Measuring range | 3 to 80% |
| Operating temperature | 0 to 60°C |
| Operating humidity | 5 to 80% |
| Measurement Object | Poultry meat (pork, beef, lamb, chicken, etc.) |
| Moisture Measurement Range | 10% to 90% |
| Sampling Time | < 2s |
| Measurement Error In The Range | 70 to 78% ≤ 1.0% |
| Sample weight | 0.001 to 120.000 g |
| Weighing range | 0.001 to 120.000 g |
| Moisture measurement range | 0.00 to 100 % |
| Dry weight measurement range | 100 to 0.00% |
| Measuring Range | 0 to 99 % |
| Measurement Resolution | 0.0001 |
| Measuring Distance | 20 to 40 cm |
| Light Diameter | 10 cm |
| Measuring range | 0 % to 80 % |
| Resolution | 0.001 |
| Accuracy | 0 % to 10 % : ± 0.2 % 10 5 to 40 % : ± 0.5 % 40 % to 80 % : ± 1 % |
| Probe length | 600 mm |
| Measuring range | 0 to 40 % |
| Resolution | 0.001 |
| Accuracy | 0 to 10 %: ±0.2 % 10 to 40%: ±0.5 % |
| Scanning depth | 50 mm |