Microwave Digestion System LMWD-B16 is newly designed and fully upgraded with higher performance and safer protection system. Vessel quantity of 12 and vertical design for even distribution of microwave with multi safety protection functions. Equipped with contactless sensor monitoring with no burst disk design saves consumables cost and maintenance cost. Designed with 7 inch color touch screen with user-friendly interface for easy operation. Material used TFM material for inner vessel and PEEK glass material for outer vessel prevents corrosion. Offers free temperature and pressure measurement avoids cross contamination. It is used to dissolve compounds such as heavy metals, inorganic compounds, etc.
Specifications
Vessel Quantity | 12 |
Temperature Monitoring System | Contactless IR Sensor, scan monitoring for each vessel |
Temperature Controlling Range | 50 to 400℃ |
Display Accuracy | ± 0.1℃ |
Temperature Display Accuracy | ± 0.1℃ |
Pressure Monitoring System | Contactless Sensor, scan monitoring for each vessel |
Pressure Controlling Range | 0 to 15 Mpa |
Pressure Accuracy | ±0.01 Mpa |
Pressure Display Accuracy | ±0.01 Mpa |
Vessel Volume | 100 mL |
Sample Vessel Material | Imported TFM |
Protection Vessel Material | Peek+ Glass Fiber |
Display | 7 inch Touch Screen |
Rotation | 360° Continuous rotating |
Microwave Tank | 316 L stainless steel tank with corrosion-proof coating |
Microwave Power | 0 to 1000 W (Adjustable) |
Microwave Leakage | < 5 mw/cm2 |
Air Exhaust | High power corrosion-proof air blower |
Dimension | 490 × 560 × 630 mm |
Power | AC 220V±10%, 10A, 50/60 Hz |
Weight | 47 kg |
Features
Offers vessel quantity of 12 vessels to meet different digestion requirements
Vertical design for even distribution of microwave
Its controlling temperature ranges from 50 to 400℃
Pressure controlling range is 0 to 15 MPa
Equipped with contactless sensor monitoring with no burst disk design saves consumables cost and maintenance cost
Real-time monitoring for both temperature and pressure of each vessel
Imported vessel material for both sample vessel and protection vessel highly ensures safety
Designed with 7 inch color touch screen with user-friendly interface for easy operation
Adopts CFRP outer shell material with high strength ensures impact resistance
Pre-installed general standard methods to save, modify and delete the method
Material used 316 L industrial stainless steel tank with multilayer teflon coating avoids acid corrosion, also improved cooling efficiency
Applications
Microwave Digestion System is used to dissolve compounds such as heavy metals, inorganic compounds, filters and sediments in food, textile, plastic, geology, metallurgy, coal, bio-pharmaceutical, petrochemical, environmental monitoring, wastewater treatment, battery manufacturing, cosmetics and other fields.
Request Quote
Vessel Quantity | 6 |
Temperature Monitoring System | Contactless IR Sensor, scan monitoring for each vessel |
Temperature Controlling Range | 50 to 400℃ |
Display Accuracy | ± 0.1℃ |
Temperature Display Accuracy | ± 0.1℃ |
Pressure Monitoring System | Contactless Sensor, scan monitoring for each vessel |
Pressure Controlling Range | 0 to 15 MPa |
Pressure Accuracy | ±0.01 MPa |
Pressure Display Accuracy | ±0.01 Mpa |
Vessel Volume | 100 mL |
Sample Vessel Material | Imported TFM |
Protection Vessel Material | Peek+ Glass Fiber |
Display | 7 inch Touch Screen |
Rotation | 360° Continuous rotating |
Microwave Tank | 316 L stainless steel tank with corrosion-proof coating |
Microwave Power | 0 to 1000 W (Adjustable) |
Microwave Leakage | < 5 mw/cm2 |
Air Exhaust | High power corrosion-proof air blower |
Dimension | 490 × 560 × 630 mm |
Power | AC 220V±10%, 10A, 50/60 Hz |
Weight | 47 kg |
Vessel Quantity | 8 |
Temperature Monitoring System | Contactless IR Sensor, scan monitoring for each vessel |
Temperature Controlling Range | 50 to 400℃ |
Display Accuracy | ± 0.1℃ |
Temperature Display Accuracy | ± 0.1℃ |
Pressure Monitoring System | Contactless Sensor, scan monitoring for each vessel |
Pressure Controlling Range | 0 to 15 Mpa |
Pressure Accuracy | ±0.01 Mpa |
Pressure Display Accuracy | ±0.01 Mpa |
Vessel Volume | 100 mL |
Sample Vessel Material | Imported TFM |
Protection Vessel Material | Peek+ Glass Fiber |
Display | 7 inch Touch Screen |
Rotation | 360° Continuous rotating |
Microwave Tank | 316 L stainless steel tank with corrosion-proof coating |
Microwave Power | 0 to 1000 W (Adjustable) |
Microwave Leakage | < 5 mw/cm2 |
Air Exhaust | High power corrosion-proof air blower |
Dimension | 490 × 560 × 630 mm |
Power | AC 220V±10%, 10A, 50/60 Hz |
Weight | 47 kg |
Vessel Quantity | 10 |
Temperature Monitoring System | Contactless IR Sensor, scan monitoring for each vessel |
Temperature Controlling Range | 50 to 400℃ |
Display Accuracy | ± 0.1℃ |
Temperature Display Accuracy | ± 0.1℃ |
Pressure Monitoring System | Contactless Sensor, scan monitoring for each vessel |
Pressure Controlling Range | 0 to 15 Mpa |
Pressure Accuracy | ±0.01 Mpa |
Pressure Display Accuracy | ±0.01 Mpa |
Vessel Volume | 100 mL |
Sample Vessel Material | Imported TFM |
Protection Vessel Material | Peek+ Glass Fiber |
Display | 7 inch Touch Screen |
Rotation | 360° Continuous rotating |
Microwave Tank | 316 L stainless steel tank with corrosion-proof coating |
Microwave Power | 0 to 1000 W (Adjustable) |
Microwave Leakage | < 5 mw/cm2 |
Air Exhaust | High power corrosion-proof air blower |
Dimension | 490 × 560 × 630 mm |
Power | AC 220V±10%, 10A, 50/60 Hz |
Weight | 47 kg |
Cavity | 48 L Resonant Cavity |
Teflon Coating | 10 |
Power Output | 1600 W |
Digestion Method | 20 preinstalled methods, programming 50 method |
Max. Temperature | 305 ℃ |
Temperature Accuracy | ± 1 ℃ |
Temperature Sensor | Optical fiber sensor |
Running Abnormal Monitoring | No |
Vessel Pressure Capacity | 75 MPa |
Vessel Quantity | 1 - 12 / batch |
Vessel Volume | 100 mL |
Microwave Cavity | SS316 with 8 layer Teflon |
Cooling Method | Forced Air Cooling |
Interface | No |
Wi-Fi Module | No |
Power Supply | 220 VAC ± 10 % 50 Hz |
Detection Of Abnormal Voltage | Yes |
Video Monitoring | No |
Dimension | 770×700×890 |
Weight | 80 kg |
Microwave Digestion System LMWD-A11
Cavity | 48 L Resonant Cavity |
Teflon Coating | 10 |
Power Output | 1600 W |
Digestion Method | 50 preinstalled methods, programming 100 method |
Max. Temperature | 305 ℃ |
Temperature range | - 40°C - 305° |
Temperature Accuracy | ± 1 ℃ |
Temperature Sensor | Optical fiber sensor |
Running Abnormal Monitoring | Yes |
Pressure accuracy | ± 0.01 Mpa |
Max pressure | 80 Mpa |
Vessel Pressure Capacity | 80 MPa |
Vessel Quantity | 1 - 12 / batch |
Vessel Volume | 100 mL |
Microwave Cavity | SS316 with 10 layer Teflon |
Cooling Method | Forced Air Cooling |
Interface | USB RS 232 |
Wi-Fi Module | Optional |
Display | 7" LCD screen |
Control mode | Touch screen |
Power Supply | 220 VAC ± 10 % 50 Hz |
Detection Of Abnormal Voltage | Yes |
Video Monitoring | Yes |
Dimensions | 520 × 593 × 660 mm |
Weight | 67 kg |
Microwave Digestion System LMWD-B12
Sample quantity | 12 per batch |
Chamber volume | 100 ml |
Rotation mode | 360° continuous rotation |
Microwave power | 0 to 2000 W adjustable |
Microwave frequency | 2450 MHz |
Pressure control range | 0 to 10 MPa |
Maximum working pressure | 6 MPa |
Pressure control accuracy | 0.01 MPa |
Outer vessel pressure limit | 20 MPa |
Temperature control range | 50 to 400 °C |
Temperature limit | |
Maximum working temperature | 250 °C |
Temperature control accuracy | ± 0.3 °C |
Heating method | |
Inner vessel temperature limit | 300 °C |
Microwave leak | < 5 mW / cm4 |
Inner vessel material | TFM |
Outer vessel material | PEEK + glass fiber |
Explosion proof frame | Polypropylene Glass Fiber |
Temperature control | |
Temperature testing | Contactless |
Pressure control | |
Pressure testing | Contactless |
Display | 8 inch touch screen |
Power | AC 220 V 16A , 50 Hz / 60 Hz |
Dimension | 640 x 630 x 590 mm |
Weight | 70 kgs |
Microwave Digestion System LMWD-B13
Sample quantity | 18 per batch |
Chamber volume | 100 ml |
Rotation mode | 360° continuous rotation |
Microwave power | 0 to 3000 W adjustable |
Microwave frequency | 2450 MHz |
Pressure control range | 0 to 10 MPa |
Maximum working pressure | 6 MPa |
Pressure control accuracy | 0.01 MPa |
Outer vessel pressure limit | 20 MPa |
Temperature control range | 50 to 400 °C |
Temperature limit | |
Maximum working temperature | 250 °C |
Temperature control accuracy | ± 0.3 °C |
Heating method | |
Inner vessel temperature limit | 300 °C |
Microwave leak | < 5 mW / cm5 |
Inner vessel material | TFM |
Outer vessel material | PEEK + glass fiber |
Explosion proof frame | Polypropylene Glass Fiber |
Temperature control | |
Temperature testing | Contactless |
Pressure control | |
Pressure testing | Contactless |
Display | 8 inch touch screen |
Power | AC 220 V 16A , 50 Hz / 60 Hz |
Dimension | 640 x 630 x 590 mm |
Weight | 75 kgs |
Microwave Digestion System LMWD-B14
Sample quantity | 40 per batch |
Chamber volume | 50 ml |
Rotation mode | 360° continuous rotation |
Microwave power | 0 to 3000 W adjustable |
Microwave frequency | 2450 MHz |
Pressure control range | 0 to 10 MPa |
Maximum working pressure | 6 MPa |
Pressure control accuracy | 0.01 MPa |
Outer vessel pressure limit | 20 MPa |
Temperature control range | 50 to 400 °C |
Temperature limit | |
Maximum working temperature | 250 °C |
Temperature control accuracy | ± 0.3 °C |
Heating method | |
Inner vessel temperature limit | 300 °C |
Microwave leak | < 5 mW / cm6 |
Inner vessel material | TFM |
Outer vessel material | PEEK + glass fiber |
Explosion proof frame | Polypropylene Glass Fiber |
Temperature control | |
Temperature testing | Contactless |
Pressure control | |
Pressure testing | Contactless |
Display | 8 inch touch screen |
Power | AC 220 V 16A , 50 Hz / 60 Hz |
Dimension | 640 x 630 x 590 mm |
Weight | 78 kgs |
Microwave Digestion System LMWD-A12
Power | 220 - 240 VAC 50 / 60 Hz 8 A |
Microwave Frequency | 2450 MHz |
Installed Power | 1800 W |
Maximum Output Power | 1000 W, non-pulse continuous automatic variable frequency control |
Turntable Design | Load 8 MP - 100 closed digestion vessels at same time |
Pressure Measurement And Control System | Piezoelectric crystal pressure sensor, pressure control range : 0 -10 MPa (1500 psi ), accuracy ± 0.01 MPa |
Temperature Measurement And Control System | High-precision platinum resistor temperature sensor, temperature range : 0 – 300 °C, accuracy ± 1℃ |
Outer Vessel Material | Explosion-proof outer vessel made of aerospace composite fiber |
Inner Vessel Material | TFM material |
Chamber Exhaust System | High-power anticorrosion axial fan, exhaust speed: 3.1 m3 / min |
Operating Temperature | 0 – 40 °C |
Working Humidity | 15 - 80 % RH |
Whole Physical Size ( W x D x H ) | 450 x 515 x 510 mm |
Net Weight | 40 kg |