Nucleic Acid Purification System LNAP-A20 is a benchtop unit comes with sample quantity of 10 and process volume ranges from 50 to 1000 µl. Adopted with magnetic bead separation technology with consumable of 5 ml tube strip and magnetic rod’s tip. Offers elution temperature ranges from ambient temperature to 120°C and lysis temperature ranges from ambient temperature to 120°C. Built-in exhaust fan, lighting LED lights to observe running status of the instrument in real time and 4.3 inch touch screen display. Integrated with program management includes PC software, APP software, program editing, setting and management procedures.

Specifications Features Applications Optional Accessories Get Quote View Catalog

Specifications

Maximum Sample Volume 5 ml
Sample Quantity 10
Process Volume 50 to 1000 µl
Consumable 5 ml tube strip+ Magnetic rod’s tip
Throughput 1 to 10
Block Heating None
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Purification Accuracy 100 Copy sample positive rate > 95 %
Stability CV < 5 %
Collection Efficiency > 95 %
Mixing Mixing methods is editable according to different requirements
Operation Interface 4.3 inch touch screen, 3 shortcut keys, external mouse
Built-in Protocol Pre-set 6 group programs, 100 pcs program can be saved
Program Management PC software, APP software, Program editing, Easier management
Extension Interface Standard USB, LAN, Wi-Fi
Lighting Yes
Pollution Control UV light
Exhaust Way By Fan
Data Storage Built-in SD card
Maximum Input Power 300 W
Dimension 340×350×410 mm
Weight 18 kg

Features

High yield of nucleic acid with low magnetic bead loss and good repeatability of results

Large guide rail design offers more reliable structure and Screw rod design provide high operating accuracy

4.3 inch touch screen display for ease of monitoring various parameters

Space saving design with maximum sample volume of 5 ml

10 samples can be processed at a same time

Avoid cross contamination and provide UV disinfection

Integrated with elution, lysis and heating function

Manual setting of open instrument parameters

APP software (Android system) which can monitor the system in real time through mobile device

Built in with function such as QR code identification, magnetic absorption and release, mixing speed, cooling fan and other function

Applications

Nucleic Acid Purification System is widely used in extraction of nucleic acids in animal and plant tissues, blood, body fluids, criminal examinations, DNA and RNA. It is suitable to use in molecular biology, biotechnology, immunology, cell and microbiology.

Optional Accessories

Tube Strips
Magnetic Rod's Tip

Request Quote

Nucleic Acid Purification System

Nucleic Acid Purification System LNAP-A21

Maximum Sample Volume 5 ml
Sample Quantity 10
Process Volume 50 to 1000 µl
Consumable 5 ml tube strip+ Magnetic rod’s tip
Throughput 1 to 10
Block Heating Yes (RT + 5°C to 105°C)
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Purification Accuracy 100 Copy sample positive rate > 95 %
Stability CV < 5 %
Collection Efficiency > 95 %
Mixing Mixing methods is editable according to different requirements
Operation Interface 4.3 inch touch screen, 3 shortcut keys, external mouse
Built-in Protocol Pre-set 6 group programs, 100 pcs program can be saved
Program Management PC software, APP software, Program editing, Easier management
Extension Interface Standard USB, LAN, Wi-Fi
Lighting Yes
Pollution Control UV light
Exhaust Way By Fan
Data Storage Built-in SD card
Maximum Input Power 350 W
Dimension 340×350×410 mm
Weight 18.5 kg

Nucleic Acid Purification System LNAP-A30

Maximum Processing Volume 1 ml
Sample Quantity 16
Process Volume 50 to 1000 µl
Consumable 96 Deep well plate and Magnetic rod’s tip
Throughput 1 to 16
Block Heating None
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
PurificationAccuracy 100 Copy sample positive rate > 95 %
Stability CV < 5 %
Collection Efficiency > 95 %
Short Operation Time 15 to 40 min per run
Mixing Mixing methods is editable according to different requirements
Operation Interface 4.3 inch touch screen, 3 shortcut keys, external mouse
Built-in Protocol Pre-set 6 group programs, 100 pcs program can be saved
Program Management PC software, APP software, Program editing, Easier management
Extension Interface Standard USB, LAN, Wi-Fi
Lighting Yes
Pollution Control UV light
Exhaust Way By Fan
Data Storage Built-in SD card
Maximum Input Power 300 W
Dimension 340×350×410 mm
Weight 18 kg
Nucleic Acid Purification System LNAP-A40
Maximum Processing Volume 10 ml
Sample Quantity 24
Process Volume 200 to 10000 µl
Consumable 10 ml tube strips and magnetic rod’s tip
Throughput 1 to 24
Working Principle Magnetic beads method
Purification Accuracy 100 copy sample positive rate > 95 %
Stability CV < 5 %
Magnetic Beads Recycling Rate > 95 %
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Mixing Mixing ways can be editable
Operation Interface 7-inch touch screen, 3 shortcut buttons and mouse is available
Built-In Protocol 8 groups of pre-set protocols, 100 groups of protocols can be stored
Protocol Management New, Edit, Delete, Save as
Expansion Interface Standard USB, Ethernet port and WIFI are available
Lighting Yes
Exhaust Way By fan
Data Storage Available with built-in SD card
Maximum Input Power 300 W
Dimension 560×620×500 mm
Weight 54 kg
Nucleic Acid Purification System LNAP-A50
Maximum Processing Volume 1ml
Sample Quantity 96
Process Volume 50 to 1000 µl
Consumable 96 Deep well plate and 96 magnetic rod’s tip
Throughput 1 to 96
Working Principle Magnetic beads method
Purification Accuracy 100 copy sample positive rate > 95 %
Stability CV < 5 %
Magnetic Beads Recycling Rate > 95 %
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Mixing Mixing ways can be editable
Operation Interface 7-inch touch screen, 3 shortcut buttons and mouse is available
Built-In Protocol 8 groups of pre-set protocols, 100 groups of protocols can be stored
Protocol Management New, Edit, Delete, Save as
Expansion Interface Standard USB, Ethernet port and WIFI are available
Lighting Yes
Exhaust Way By fan
Data Storage Available with built-in SD card
Maximum Input Power 300 W
Dimension 560×620×500 mm
Weight 54 kg

Nucleic acid purification system LNAP-A10

Throughput 1 ~ 20
Process volume 50 µl ~ 3000 µl
Collection efficiency > 95 %
Magnetic rod number 20
Purification accuracy 100 copy sample positive rate > 95%
Stability CV < 5%
Plate types 3 ml tube strip
Heating for lysis tube Ambient temperature ~ 120°C
Heating for elution tube Ambient temperature ~ 120°C
Operation 7 inch color touch screen
Extraction steps Lysis, Sample binding, Washing and elution
Storage capacity more than 100 programs
Protocol management Create, edit, delete, protocol mode
Pollution control UV light
Lighting Yes
Extension interface 4 standard USB port, built-in SD card
Exhaust Fan
Power supply 450 W
Dimensions 400 × 520 × 450 mm
Weight 28 kgs

Nucleic acid purification system LNAP-A11

Throughput 1 ~ 20
Process volume 50 µl ~ 5000 µl
Collection efficiency > 95 %
Magnetic rod number 20
Purification accuracy 100 copy sample positive rate > 95%
Stability CV < 5%
Plate types 5 ml tube strip
Heating for lysis tube Ambient temperature ~ 120°C
Heating for elution tube Ambient temperature ~ 120°C
Operation 7 inch color touch screen
Extraction steps Lysis, Sample binding, Washing and elution
Storage capacity more than 100 programs
Protocol management Create, edit, delete, protocol mode
Pollution control UV light
Lighting Yes
Extension interface 4 standard USB port, built-in SD card
Exhaust Fan
Power supply 450 W
Dimensions 400 × 520 × 450 mm
Weight 28 kgs

Nucleic acid purification system LNAP-A12

Throughput 1 ~ 32
Process volume 50 µl ~ 1000 µl
Collection efficiency > 95 %
Magnetic rod number 32
Purification accuracy 100 copy sample positive rate > 95%
Stability CV < 5%
Plate types 96 deep well plate
Heating for lysis tube Ambient temperature ~ 120°C
Heating for elution tube Ambient temperature ~ 120°C
Operation 7 inch color touch screen
Extraction steps Lysis, Sample binding, Washing and elution
Storage capacity more than 100 programs
Protocol management Create, edit, delete, protocol mode
Pollution control UV light
Lighting Yes
Extension interface 4 standard USB port, built-in SD card
Exhaust Fan
Power supply 450 W
Dimensions 400 × 470 × 450 mm
Weight 25 kgs