Test Chamber
We produce various types of Test Chambers, which are widely used in managed and controlled environments to test the endurance, stability, and practicality of equipment, products, and chemicals. Select the test chamber that best meets your requirements.
Ozone Test Chamber LOC-A10
Temperature range : |
0℃ ~ 100℃ |
Humidity range : |
30 % - 98 % R.H |
Temperature fluctuation : |
± 0.5 ℃ |
Speed rate for cooling : |
Ambient ~ 0 ℃ within 20 min |
Ozone Test Chamber LOC-A11
Diameter of holder (mm) : |
400 |
Length of each side (mm) : |
180 |
Temperature range : |
0℃ ~ 100℃ |
Humidity range : |
30 % - 98 % R.H |
Ozone Test Chamber LOC-A12
Diameter of holder (mm) : |
600 |
Length of each side (mm) : |
220 |
Temperature range : |
0℃ ~ 100℃ |
Humidity range : |
30 % - 98 % R.H |
Ozone Test Chamber LOC-A13
Diameter of holder (mm) : |
700 |
Length of each side (mm) : |
350 |
Temperature range : |
0℃ ~ 100℃ |
Humidity range : |
30 % - 98 % R.H |
Ozone Test Chamber LOC-A14
Diameter of holder (mm) : |
900 |
Length of each side (mm) : |
460 |
Temperature range : |
0℃ ~ 100℃ |
Humidity range : |
30 % - 98 % R.H |
Plant Growth Chamber LPGC-A10
Chamber Volume : |
300 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-A11
Chamber Volume : |
450 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-A12
Chamber Volume : |
800 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-A13
Chamber Volume : |
1000 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-B10
Chamber Volume : |
250 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-B11
Chamber Volume : |
300 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-B12
Chamber Volume : |
450 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-B13
Chamber Volume : |
800 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Plant Growth Chamber LPGC-B14
Chamber Volume : |
1000 L |
Shelves : |
3(PCS) |
Display Resolution : |
0.1 ℃ |
Temperature Range : |
Without Lighting: 0 to 50℃
With lighting:10 to 50℃ |
Salt Spray Test Chamber LSSC-A10
Testing room capacity : |
110 L |
Temperature range : |
Ambient to +60°C |
Humidity range : |
95 to 98% RH |
Temperature Fluctuation : |
± 0.5 ℃ |
Salt Spray Test Chamber LSSC-A11
Testing room capacity : |
326 L |
Temperature range : |
Ambient to +60°C |
Humidity range : |
95 to 98% RH |
Temperature Fluctuation : |
± 0.5 ℃ |
Salt Spray Test Chamber LSSC-A12
Testing room capacity : |
410 L |
Temperature range : |
Ambient to +60°C |
Humidity range : |
95 to 98% RH |
Temperature Fluctuation : |
± 0.5 ℃ |
Salt Spray Test Chamber LSSC-A13
Testing room capacity : |
780 L |
Temperature range : |
Ambient to +60°C |
Humidity range : |
95% to 98% RH |
Temperature Fluctuation : |
± 0.5 ℃ |
Salt Spray Test Chamber LSSC-A14
Testing room capacity : |
1030 L |
Temperature range : |
Ambient to +60°C |
Humidity range : |
95% to 98% RH |
Temperature Fluctuation : |
± 0.5 ℃ |
Salt Spray Test Chamber LSSC-A15
Testing room capacity : |
1600 L |
Temperature range : |
Ambient to +60°C |
Humidity range : |
95% to 98% RH |
Temperature Fluctuation : |
± 0.5 ℃ |
Sand and Dust Test Chamber LSC-A10
Temperature range : |
Ambient to + 50 ℃ |
Relative Humidity : |
< 30 % RH |
Normal wire diameter : |
50 um |
Normal width of a gap between wire : |
75 um |
Sand and Dust Test Chamber LSC-A11
Temperature range : |
Ambient to + 50 ℃ |
Relative Humidity : |
< 30 % RH |
Normal wire diameter : |
50 um |
Normal width of a gap between wire : |
75 um |
Sand and Dust Test Chamber LSC-A12
Temperature range : |
Ambient to + 50 ℃ |
Relative Humidity : |
< 30 % RH |
Normal wire diameter : |
50 um |
Normal width of a gap between wire : |
75 um |
Sand and Dust Test Chamber LSC-A13
Temperature range : |
Ambient to + 50 ℃ |
Relative Humidity : |
< 30 % RH |
Normal wire diameter : |
50 um |
Normal width of a gap between wire : |
75 um |
UV Test Chamber LUVC-A10
UV Temperature : |
50 °C to 75 °C |
Testing Capacity : |
48 piece (75 x 150 mm); 50 piece (75x 150 mm) |
Weight : |
136 kg |
Water Consumption : |
Distilled water, 8liters per day |
UV Test Chamber LUVC-A20
Temperature Range : |
RT + 100 °C ~ 850 °C |
Humidity range : |
At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 % |
Testing Time : |
20 hours |
Testing Voltage : |
120 V ~ 145 V (135 V) |
UV Test Chamber LUVC-A21
Temperature Range : |
RT + 100 °C ~ 630 °C |
Humidity range : |
30 % ~ 85 % RH |
Testing Time : |
20 hours |
Testing Voltage : |
120 V ~ 145 V |
Xenon Test Chamber LXC-A10
Bandwidth Measurement (nm) : |
280 ~ 800 |
Specimen Capacity (pcs) : |
28 |
Specimen holder size (mm) : |
80 × 15 |
Chamber Temperature Range : |
Ambient ~ 100 ℃ ± 2 °C |
Xenon Test Chamber LXC-A11
Bandwidth Measurement (nm) : |
300 - 420 |
Specimen Capacity (pcs) : |
34 |
Specimen holder size (mm) : |
80 × 15 |
Chamber Temperature Range : |
Ambient ~ 100 ℃ ± 2 °C |
Xenon Test Chamber LXC-A20
Bandwidth Measurement (nm) : |
280 ~ 800 |
Specimen Capacity (pcs) : |
28 |
Specimen holder size (mm) : |
80 × 15 |
Chamber Temperature Range : |
Ambient ~ 100 ℃ ± 2 °C |
Xenon Test Chamber LXC-A21
Bandwidth Measurement (nm) : |
300 - 420 |
Specimen Capacity (pcs) : |
34 |
Specimen holder size (mm) : |
80 × 15 |
Chamber Temperature Range : |
Ambient ~ 100 ℃ ± 2 °C |
Xenon Test Chamber LXC-A22
Temperature Range : |
RT+50℃ to 70℃ |
Temperature Fluctuation : |
±3℃ |
Cooling Way : |
Air-cooled |
Raining Time : |
0-99min adjustable |