Labtron manufactures LSC-A11 an excellent quality, corrosion resistant sand test chamber that test the stability, quality, reactivity and characteristics of product against the sand and dust exposed environmental conditions. The test chamber is carefully designed as per the CE and ISO standards and provides protection against current leakage, overload, over-current, short circuit, over temperature, motor overheating, over pressure for safe and precise results.
Specifications
Temperature range | Ambient to + 50 ℃ |
Relative Humidity | < 30 % RH |
Normal wire diameter | 50 um |
Normal width of a gap between wire | 75 um |
The Talcum powder amount | 2 kg ~ 4 kg / m3 |
Fight time | 0 ~ 99 H 59 M |
Fan cycle time | 0 ~ 99 H 59 M |
Specimen power outlet | Dust-proof socket AC220V 16A |
Vacuum system | Equipped with a pressure gauge, air filter, pressure regulator, connecting tube |
Circulating fan | Enclosed alloy low-noise motor, multi-vane centrifugal fan |
Heating system | Independent Nichrome electronic heating system |
Internal dimensions | 1000 × 1000 × 1000 mm |
Overall dimensions | 1200 × 1450 × 1960 mm |
Nominal power | 7500 W |
Power supply | 380 V 50 Hz |
Features
PID programmable controller with LCD touch screen display
Circulatory pump system uses effective dust re-cycle blowing
Uses enclosed heater to keep dust dry
Made up of corrosion resistant stainless steel material
Protection against current leakage, overload, over-current, short circuit, over temperature, motor overheating, over pressure
Applications
Used to test the products quality such as electronic, plastic products, electrical appliances, metals, chemicals, building materials, aerospace, medical care, food and beverages.
Request Quote
Interior Volume | 100 L |
Heat load | 1000 W |
Temperature Range | 0℃ to 100 ℃ |
Temperature Deviation in time | ± 2.0 ℃ |
Temperature Fluctuation | ± 0.5 ℃ |
Humidity Range | 20% to 98% RH |
Humidity Deviation in time | ± 2.5% RH |
Cooling Rate | 1 ℃ / min |
Heating Rate | 3 ℃ / min |
Cooling system | Mechanical compression refrigeration system |
Refrigerating unit | French TECUMSEH compressor |
Refrigerant | R404A, R23 |
Heating Element | Nichrome heater |
Controller | Programmable color LCD touch screen controller Ethernet connection, PC Link |
Water supply system | Automatic water supply Water purification system |
Humidifier | External isolation, stainless steel surface evaporation humidifier |
Dehumidification | Evaporator |
Temperature Sensor | PTR Platinum Resistance PT100 Ω/MV A-class, accuracy 0.001℃ |
Humidity Sensor | Dry and wet bulb sensor |
Build-in Water Tank | 270 × 300 × 400 mm |
View Window Size | 250 × 280 mm |
Air Circulation | Centrifugal wind fan |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Thermal Insulation | Polyurethane foam and insulation cotton |
Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing |
Standard Configuration | 1 Cable hole (Φ 50,) with plug; 2 shelves |
Maximum Noise | 65 dBA |
Ambient Temperature | 5℃ to +35 ℃ |
Relative Humidity | ≤ 85% RH |
Internal dimension | 400 × 500 × 500 mm |
External dimension | 860 × 1050 × 1620 mm |
Power Supply | 220 V, 50 Hz / 380 V, 50 Hz |
Net weight | 290 kg |
Gross weight | 340 kg |
Interior Volume | 225 L |
Heat load | 1000 W |
Temperature Range | 0℃ to 100 ℃ |
Temperature Deviation in time | ± 2.0 ℃ |
Temperature Fluctuation | ± 0.5 ℃ |
Humidity Range | 20% to 98% RH |
Humidity Deviation in time | ± 2.5% RH |
Cooling Rate | 1 ℃ / min |
Heating Rate | 3 ℃ / min |
Cooling system | Mechanical compression refrigeration system |
Refrigerating unit | French TECUMSEH compressor |
Refrigerant | R404A, R23 |
Heating Element | Nichrome heater |
Controller | Programmable color LCD touch screen controller Ethernet connection, PC Link |
Water supply system | Automatic water supply Water purification system |
Humidifier | External isolation, stainless steel surface evaporation humidifier |
Dehumidification | Evaporator |
Temperature Sensor | PTR Platinum Resistance PT100 Ω/MV A-class, accuracy 0.001℃ |
Humidity Sensor | Dry and wet bulb sensor |
Build-in Water Tank | 270 × 300 × 400 mm |
View Window Size | 250 × 280 mm |
Air Circulation | Centrifugal wind fan |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Thermal Insulation | Polyurethane foam and insulation cotton |
Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing |
Standard Configuration | 1 Cable hole (Φ 50,) with plug; 2 shelves |
Maximum Noise | 65 dBA |
Ambient Temperature | 5℃ to +35 ℃ |
Relative Humidity | ≤ 85% RH |
Internal dimension | 500 × 600 × 750 mm |
External dimension | 960 × 1150 × 1860 mm |
Power Supply | 220 V, 50 Hz / 380 V, 50 Hz |
Net weight | 400 kg |
Gross weight | 440 kg |
Interior Volume | 500 L |
Heat load | 1000 W |
Temperature Range | 0℃ to 100 ℃ |
Temperature Deviation in time | ± 2.0 ℃ |
Temperature Fluctuation | ± 0.5 ℃ |
Humidity Range | 20% to 98% RH |
Humidity Deviation in time | ± 2.5% RH |
Cooling Rate | 1 ℃ / min |
Heating Rate | 3 ℃ / min |
Cooling system | Mechanical compression refrigeration system |
Refrigerating unit | French TECUMSEH compressor |
Refrigerant | R404A, R23 |
Heating Element | Nichrome heater |
Controller | Programmable color LCD touch screen controller Ethernet connection, PC Link |
Water supply system | Automatic water supply Water purification system |
Humidifier | External isolation, stainless steel surface evaporation humidifier |
Dehumidification | Evaporator |
Temperature Sensor | PTR Platinum Resistance PT100 Ω/MV A-class, accuracy 0.001℃ |
Humidity Sensor | Dry and wet bulb sensor |
Build-in Water Tank | 270 × 300 × 450 mm |
View Window Size | 300 × 330 mm |
Air Circulation | Centrifugal wind fan |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Thermal Insulation | Polyurethane foam and insulation cotton |
Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing |
Standard Configuration | 1 Cable hole (Φ 50,) with plug; 2 shelves |
Maximum Noise | 65 dBA |
Ambient Temperature | 5℃ to +35 ℃ |
Relative Humidity | ≤ 85% RH |
Internal dimension | 700 × 800 × 900 mm |
External dimension | 1180 × 1350 × 2010 mm |
Power Supply | 220 V, 50 Hz / 380 V, 50 Hz |
Net weight | 515 kg |
Gross weight | 550 kg |
Interior Volume | 800 L |
Heat load | 1000 W |
Temperature Range | 0℃ to 100 ℃ |
Temperature Deviation in time | ± 2.0 ℃ |
Temperature Fluctuation | ± 0.5 ℃ |
Humidity Range | 20% to 98% RH |
Humidity Deviation in time | ± 2.5% RH |
Cooling Rate | 1 ℃ / min |
Heating Rate | 3 ℃ / min |
Cooling system | Mechanical compression refrigeration system |
Refrigerating unit | French TECUMSEH compressor |
Refrigerant | R404A, R23 |
Heating Element | Nichrome heater |
Controller | Programmable color LCD touch screen controller Ethernet connection, PC Link |
Water supply system | Automatic water supply Water purification system |
Humidifier | External isolation, stainless steel surface evaporation humidifier |
Dehumidification | Evaporator |
Temperature Sensor | PTR Platinum Resistance PT100 Ω/MV A-class, accuracy 0.001℃ |
Humidity Sensor | Dry and wet bulb sensor |
Build-in Water Tank | 270 × 300 × 450 mm |
View Window Size | 300 × 330 mm |
Air Circulation | Centrifugal wind fan |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Thermal Insulation | Polyurethane foam and insulation cotton |
Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing |
Standard Configuration | 1 Cable hole (Φ 50,) with plug; 2 shelves |
Maximum Noise | 65 dBA |
Ambient Temperature | 5℃ to +35 ℃ |
Relative Humidity | ≤ 85% RH |
Internal dimension | 800 × 1000 × 1000 mm |
External dimension | 1280 × 1550 × 2110 mm |
Power Supply | 220 V, 50 Hz / 380 V, 50 Hz |
Net weight | 550 kg |
Gross weight | 600 kg |
Diameter of holder (mm) | |
Length of each side (mm) | |
Temperature range | 0℃ ~ 100℃ |
Humidity range | 30 % - 98 % R.H |
Temperature fluctuation | ± 0.5 ℃ |
Speed rate for cooling | Ambient ~ 0 ℃ within 20 min |
Timing range | 0 ~ 999 hours |
Ozone concentration | 1 ~ 1000PPHM |
Sample holder rotate speed | 0 ~ 10 r/min (adjustable) |
Clamps tensile stretch | 5 % ~ 35 % |
Max. ozone concentration | 120 g O3/m³ |
Ozone output | 3.5 g O3/h (oxygen input, flow rate 100L/h) |
Nominal power | 5500 W |
Internal dimensions | 400 × 500 × 500 mm |
Overall dimensions (mm) | 860 × 1050 × 1620 mm |
Power & voltage | AC 380 V 50Hz |
Diameter of holder (mm) | 400 |
Length of each side (mm) | 180 |
Temperature range | 0℃ ~ 100℃ |
Humidity range | 30 % - 98 % R.H |
Temperature fluctuation | ± 0.5 ℃ |
Speed rate for cooling | Ambient ~ 0 ℃ within 20 min |
Timing range | 0 ~ 999 hours |
Ozone concentration | 1 ~ 1000PPHM |
Sample holder rotate speed | 0 ~ 10 r/min (adjustable) |
Clamps tensile stretch | 5 % ~ 35 % |
Max. ozone concentration | 120 g O3/m³ |
Ozone output | 3.5 g O3/h (oxygen input, flow rate 100L/h) |
Nominal power | 6000 W |
Internal dimensions | 600 × 600 × 700 mm |
Overall dimensions (mm) | 960 × 1150 × 1860 mm |
Power & voltage | AC 380 V 50Hz |
Diameter of holder (mm) | 600 |
Length of each side (mm) | 220 |
Temperature range | 0℃ ~ 100℃ |
Humidity range | 30 % - 98 % R.H |
Temperature fluctuation | ± 0.5 ℃ |
Speed rate for cooling | Ambient ~ 0 ℃ within 20 min |
Timing range | 0 ~ 999 hours |
Ozone concentration | 1 ~ 1000PPHM |
Sample holder rotate speed | 0 ~ 10 r/min (adjustable) |
Clamps tensile stretch | 5 % ~ 35 % |
Max. ozone concentration | 120 g O3/m³ |
Ozone output | 3.5 g O3/h (oxygen input, flow rate 100L/h) |
Nominal power | 7500 W |
Internal dimensions | 700 × 800 × 900 mm |
Overall dimensions (mm) | 1180 × 1350 × 2010 mm |
Power & voltage | AC 380 V 50Hz |
Diameter of holder (mm) | 700 |
Length of each side (mm) | 350 |
Temperature range | 0℃ ~ 100℃ |
Humidity range | 30 % - 98 % R.H |
Temperature fluctuation | ± 0.5 ℃ |
Speed rate for cooling | Ambient ~ 0 ℃ within 20 min |
Timing range | 0 ~ 999 hours |
Ozone concentration | 1 ~ 1000PPHM |
Sample holder rotate speed | 0 ~ 10 r/min (adjustable) |
Clamps tensile stretch | 5 % ~ 35 % |
Max. ozone concentration | 120 g O3/m³ |
Ozone output | 3.5 g O3/h (oxygen input, flow rate 100L/h) |
Nominal power | 9000 W |
Internal dimensions | 800 × 1000 × 1000 mm |
Overall dimensions (mm) | 1280 × 1550 × 2110 mm |
Power & voltage | AC 380 V 50Hz |
Chamber Volume | 300 L |
Shelves | 3(PCS) |
Display Resolution | 0.1 ℃ |
Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
Temperature Stability | ± 1 ℃ |
Temperature Uniformity | ± 1.5 ℃ |
Ambient Temperature | RT+5°C to 30 ℃ |
Humidity Range | 50 to 90 % RH |
Humidity Accuracy | ± 5 to 7 % RH |
Continuous Working Time | Not less than 180 h |
Lighting Intensity | 0 to 20000 LX Four-grade adjustable |
Lighting type | Three surface illumination |
Interior Dimension(W × D × H) | 520 × 550 × 1140 mm |
Exterior Dimension(W × D × H) | 830 × 850 × 1850 mm |
Power Consumption | 1700 W |
Power | 220 V 50 Hz |
Chamber Volume | 450 L |
Shelves | 3(PCS) |
Display Resolution | 0.1 ℃ |
Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
Temperature Stability | ± 1 ℃ |
Temperature Uniformity | ± 1.5 ℃ |
Ambient Temperature | RT+5°C to 30 ℃ |
Humidity Range | 50 to 90 % RH |
Humidity Accuracy | ± 5 to 7 % RH |
Continuous Working Time | Not less than 180 h |
Lighting Intensity | 0 to 25000 LX Four-grade adjustable |
Lighting type | Three surface illumination |
Interior Dimension(W × D × H) | 700 × 550 × 1140 mm |
Exterior Dimension(W × D × H) | 950 × 850 × 1850 mm |
Power Consumption | 2050 W |
Power | 220 V 50 Hz |
Chamber Volume | 800 L |
Shelves | 3(PCS) |
Display Resolution | 0.1 ℃ |
Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
Temperature Stability | ± 1 ℃ |
Temperature Uniformity | ± 2 ℃ |
Ambient Temperature | RT+5°C to 30 ℃ |
Humidity Range | 50 to 90 % RH |
Humidity Accuracy | ± 5 to 7 % RH |
Continuous Working Time | Not less than 180 h |
Lighting Intensity | 0 to 30000 LX Four-grade adjustable |
Lighting type | Shelves illumination (02 shelves) |
Interior Dimension(W × D × H) | 965 × 580 × 1430 mm |
Exterior Dimension(W × D × H) | 1475 × 890 × 1780 mm |
Power Consumption | 3700 W |
Power | 380 V 50 Hz |
Chamber Volume | 1000 L |
Shelves | 3(PCS) |
Display Resolution | 0.1 ℃ |
Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
Temperature Stability | ± 1 ℃ |
Temperature Uniformity | ± 2 ℃ |
Ambient Temperature | RT+5°C to 30 ℃ |
Humidity Range | 50 to 90 % RH |
Humidity Accuracy | ± 5 to 7 % RH |
Continuous Working Time | Not less than 180 h |
Lighting Intensity | 0 to 35000 LX Four-grade adjustable |
Lighting type | Shelves illumination (02 shelves) |
Interior Dimension(W × D × H) | 900 × 580 × 1600 mm |
Exterior Dimension(W × D × H) | 1410 × 890 × 1950 mm |
Power Consumption | 3800 W |
Power | 380 V 50 Hz |
Testing room capacity | 110 L |
Temperature range | Ambient to +60°C |
Humidity range | 95 to 98% RH |
Temperature Fluctuation | ± 0.5 ℃ |
Temperature Deviation | ± 2.0 ℃ |
Spray deposition | 1 to 2 ml / 80 cm2 .h |
Spray type | Continuous /Periodic |
Spraying system | Atomizer tower and Spray nozzle |
Air preheating | Saturated air barrel; 31 L |
Heating element | Nichrome heater |
Salt fog collection | Fog collector and Fog measure cylinder |
Standard sample holder | 6 round bars and 5 V-shaped grooves |
Controller | PID |
Sensor | PT100 Ω / MV A-class sensor |
Housing | Glass fiber reinforced plastics |
Lid | Transparent resin lid |
Sealing | Hydrostatic hood seal |
Protection | Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
Maximum noise | 65 dBA |
Power supply | 220 V 50 Hz 1 P |
Water solution tank dimension (W×D×H) | 350×180×320 mm |
Internal dimension (W×D×H) | 600×460×400 mm |
External dimension (W×D×H) | 1100×700×1000 mm |
Net weight | 110 kg |
Gross weight | 185 kg |
Testing room capacity | 326 L |
Temperature range | Ambient to +60°C |
Humidity range | 95 to 98% RH |
Temperature Fluctuation | ± 0.5 ℃ |
Temperature Deviation | ± 2.0 ℃ |
Spray deposition | 1 to 2 ml / 80 cm2 .h |
Spray type | Continuous /Periodic |
Spraying system | Atomizer tower and Spray nozzle |
Air preheating | Saturated air barrel; 31 L |
Heating element | Nichrome heater |
Salt fog collection | Fog collector and Fog measure cylinder |
Standard sample holder | 7 round bars and 6 V-shaped grooves |
Controller | PID |
Sensor | PT100 Ω / MV A-class sensor |
Housing | Glass fiber reinforced plastics |
Lid | Transparent resin lid |
Sealing | Hydrostatic hood seal |
Protection | Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
Maximum noise | 65 dBA |
Power supply | 220 V 50 Hz 1 P |
Water solution tank dimension (W×D×H) | 350×180×320 mm |
Internal dimension (W×D×H) | 1000×640×510 mm |
External dimension (W×D×H) | 1580×910×1200 mm |
Net weight | 225 kg |
Gross weight | 260 kg |
Testing room capacity | 410 L |
Temperature range | Ambient to +60°C |
Humidity range | 95 to 98% RH |
Temperature Fluctuation | ± 0.5 ℃ |
Temperature Deviation | ± 2.0 ℃ |
Spray deposition | 1 to 2 ml / 80 cm2 .h |
Spray type | Continuous /Periodic |
Spraying system | Atomizer tower and Spray nozzle |
Air preheating | Saturated air barrel; 31 L |
Heating element | Nichrome heater |
Salt fog collection | Fog collector and Fog measure cylinder |
Standard sample holder | 8 round bars and 7 V-shaped grooves |
Controller | PID |
Sensor | PT100 Ω / MV A-class sensor |
Housing | Glass fiber reinforced plastics |
Lid | Transparent resin lid |
Sealing | Hydrostatic hood seal |
Protection | Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
Maximum noise | 65 dBA |
Power supply | 220 V 50 Hz 1 P |
Water solution tank dimension (W×D×H) | 350×180×320 mm |
Internal dimension (W×D×H) | 1100×750×500 mm |
External dimension (W×D×H) | 1900×920×1200 mm |
Net weight | 260 kg |
Gross weight | 310 kg |
Testing room capacity | 780 L |
Temperature range | Ambient to +60°C |
Humidity range | 95% to 98% RH |
Temperature Fluctuation | ± 0.5 ℃ |
Temperature Deviation | ± 2.0 ℃ |
Spray deposition | 1 to 2 ml / 80 cm2 .h |
Spray type | Continuous /Periodic |
Spraying system | Atomizer tower and Spray nozzle |
Air preheating | Saturated air barrel; 31 L |
Heating element | Nichrome heater |
Salt fog collection | Fog collector and Fog measure cylinder |
Standard sample holder | 8 round bars and 7 V-shaped grooves |
Controller | PID |
Sensor | PT100 Ω / MV A-class sensor |
Housing | Glass fiber reinforced plastics |
Observation window | Glass |
Sealing | Pneumatic seal |
Protection | Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
Maximum noise | 65 dBA |
Power supply | 220 V 50 Hz 1 P |
Water solution tank dimension (W×D×H) | 600×370×350 mm |
Observation window dimension (L×B) | 800×300 mm |
Internal dimension (W×D×H) | 1300×1000×600 mm |
External dimension (W×D×H) | 2200×1200×1400 mm |
Net weight | 280 kg |
Gross weight | 450 kg |
Temperature range | Ambient to + 50 ℃ |
Relative Humidity | < 30 % RH |
Normal wire diameter | 50 um |
Normal width of a gap between wire | 75 um |
The Talcum powder amount | 2 kg ~ 4 kg / m3 |
Fight time | 0 ~ 99 H 59 M |
Fan cycle time | 0 ~ 99 H 59 M |
Specimen power outlet | Dust-proof socket AC220V 16A |
Vacuum system | Equipped with a pressure gauge, air filter, pressure regulator, connecting tube |
Circulating fan | Enclosed alloy low-noise motor, multi-vane centrifugal fan |
Heating system | Independent Nichrome electronic heating system |
Internal dimensions | 800 × 1000 × 1000 mm |
Overall dimensions | 1040 × 1450 × 1960 mm |
Nominal power | 5500 W |
Power supply | 380 V 50 Hz |
Temperature range | Ambient to + 50 ℃ |
Relative Humidity | < 30 % RH |
Normal wire diameter | 50 um |
Normal width of a gap between wire | 75 um |
The Talcum powder amount | 2 kg ~ 4 kg / m3 |
Fight time | 0 ~ 99 H 59 M |
Fan cycle time | 0 ~ 99 H 59 M |
Specimen power outlet | Dust-proof socket AC220V 16A |
Vacuum system | Equipped with a pressure gauge, air filter, pressure regulator, connecting tube |
Circulating fan | Enclosed alloy low-noise motor, multi-vane centrifugal fan |
Heating system | Independent Nichrome electronic heating system |
Internal dimensions | 1000 × 1500 × 1000 mm |
Overall dimensions | 1250 × 1900 × 1960 mm |
Nominal power | 7500 W |
Power supply | 380 V 50 Hz |
Temperature range | Ambient to + 50 ℃ |
Relative Humidity | < 30 % RH |
Normal wire diameter | 50 um |
Normal width of a gap between wire | 75 um |
The Talcum powder amount | 2 kg ~ 4 kg / m3 |
Fight time | 0 ~ 99 H 59 M |
Fan cycle time | 0 ~ 99 H 59 M |
Specimen power outlet | Dust-proof socket AC220V 16A |
Vacuum system | Equipped with a pressure gauge, air filter, pressure regulator, connecting tube |
Circulating fan | Enclosed alloy low-noise motor, multi-vane centrifugal fan |
Heating system | Independent Nichrome electronic heating system |
Internal dimensions | 1000 × 2000 × 1000 mm |
Overall dimensions | 1300 × 2400 × 1960 mm |
Nominal power | 9000 W |
Power supply | 380 V 50 Hz |
Capacity | 50 L |
Temperature range | (- 20 °C) to 150 °C |
Low type | I – 40 °C, II – 70 °C |
Environmental condition | 5 ℃ ~ + 40 ℃ ≤ 85 % RH |
Humidity range | 20 % - 98 % RH |
Temperature fluctuation | ± 0.5 °C |
Temperature deviation | ± 2 °C |
Humidity deviation | ± 2.5 % RH |
Heating rate | 3 °C / min |
Cooling rate | 1 °C / min |
Temperature sensor | PTR Platinum resistance PT 100 Ω / MV A-class |
Temperature resolution | ± 0.001 ℃ |
Humidity sensor | Dry and wet bulb sensor |
Humidity resolution | ± 1 % RH |
Internal dimension | 320 × 350 × 450 mm |
Overall dimension | 800 × 1050 × 950 mm |
Power supply | AC 220 , 50 Hz |
Capacity | 80 L |
Temperature range | (- 20 °C) to 150 °C |
Low type | I – 40 °C, II – 70 °C |
Environmental condition | 5 ℃ ~ + 40 ℃ ≤ 85 % RH |
Humidity range | 20 % - 98 % RH |
Temperature fluctuation | ± 0.5 °C |
Temperature deviation | ± 2 °C |
Humidity deviation | ± 2.5 % RH |
Heating rate | 3 °C / min |
Cooling rate | 1 °C / min |
Temperature sensor | PTR Platinum resistance PT 100 Ω / MV A-class |
Temperature resolution | ± 0.001 ℃ |
Humidity sensor | Dry and wet bulb sensor |
Humidity resolution | ± 1 % RH |
Internal dimension | 400 × 400 × 500 mm |
Overall dimension | 900 × 1100 × 1000 mm |
Power supply | AC 220 , 50 Hz |
Capacity | 100 L |
Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
Temperature cooling rate | 1 ℃ / min |
Overall dimension (D x W x H) | 860 x 1050 x 1620 mm |
Temperature heating rate | 3 ℃ / min |
Temperature fluctuations | ± 0.5 ℃ |
Temperature deviation | ± 2.0 ℃ |
Humidity range | 20 % ~ 98 % R.H |
Humidity deviation | ± 2.5 % RH |
High temperature | 180 ℃ |
Lowest humidity | 10 % RH |
Internal dimension (D x W x H) | 400 x 500 x 500 mm |
Capacity | 225 L |
Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
Temperature cooling rate | 1 ℃ / min |
Overall dimension (D x W x H) | 960 x 1150 x 1860 mm |
Temperature heating rate | 3 ℃ / min |
Temperature fluctuations | ± 0.5 ℃ |
Temperature deviation | ± 2.0 ℃ |
Humidity range | 20 % ~ 98 % R.H |
Humidity deviation | ± 2.5 % RH |
High temperature | 180 ℃ |
Lowest humidity | 10 % RH |
Internal dimension (D x W x H) | 500 x 600 x 750 mm |
Temperature Range | |
Humidity range | |
Testing Time | |
Testing Voltage | |
Testing Current | |
Black Panel Temperature | |
Black Bulb Thermometer | |
Sample Rack Size | |
Sample Rack Rotation Speed | |
Specimens capacity | |
Specimen Sample Rack | |
UV wavelength | |
UV Temperature | 50 °C to 75 °C |
Testing Capacity | 48 piece (75 x 150 mm); 50 piece (75x 150 mm) |
Irradiance Control | |
Irradiation Source | |
Weight | 136 kg |
Water Spray | |
Water Consumption | Distilled water, 8liters per day |
Distance of Specimen and lamp | |
Internal dimensions | |
Overall dimensions | |
Dimension(W x D x H) | 137 x 53 x 136 cm |
Nominal power | |
Power | 1ψ, 120 V / 60 Hz, 16 A or 230 V / 50 Hz, 9 A, 1800 W(max) |
Temperature Range | RT + 100 °C ~ 850 °C |
Humidity range | At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 % |
Testing Time | 20 hours |
Testing Voltage | 120 V ~ 145 V (135 V) |
Testing Current | 15 A ~ 17 A (16 A) |
Black Panel Temperature | |
Black Bulb Thermometer | 63 °C ± 30 °C ~ 83 °C ± 30 °C |
Sample Rack Size | 800Ø |
Sample Rack Rotation Speed | 1 rpm |
Specimens capacity | |
Specimen Sample Rack | 390 x 70 mm,30 pcs |
UV wavelength | |
UV Temperature | |
Testing Capacity | |
Irradiance Control | |
Irradiation Source | |
Weight | |
Water Spray | |
Water Consumption | |
Distance of Specimen and lamp | |
Internal dimensions | |
Overall dimensions | |
Dimension(W x D x H) | 100 x 900 x 100 cm |
Nominal power | |
Power | 1∮ 220 V 11 KVA |
Temperature Range | RT + 100 °C ~ 630 °C |
Humidity range | 30 % ~ 85 % RH |
Testing Time | 20 hours |
Testing Voltage | 120 V ~ 145 V |
Testing Current | 15 A ~ 17 A |
Black Panel Temperature | |
Black Bulb Thermometer | 63 °C ± 30 °C ~ 83 °C ± 30 °C |
Sample Rack Size | 508Ø |
Sample Rack Rotation Speed | 3 rpm |
Specimens capacity | |
Specimen Sample Rack | 248 x 50 mm, 20 pcs |
UV wavelength | |
UV Temperature | |
Testing Capacity | |
Irradiance Control | |
Irradiation Source | |
Weight | |
Water Spray | |
Water Consumption | |
Distance of Specimen and lamp | |
Internal dimensions | |
Overall dimensions | |
Dimension(W x D x H) | 130 x 130 x 200 cm |
Nominal power | |
Power | 1∮ 220 V 6 KVA |
Temperature Range | RT+50℃ to 70℃ |
Temperature Fluctuation | ±3℃ |
Cooling Way | Air-cooled |
Raining Time | 0-99min adjustable |
Irradiation Strength | 400-700w/m2 |
Wavelength | 290-800nm |
Dimming Range | 5%-100% |
Lamp Power | 2.5kW |
Total Power | 4.5kW |
Power Supply | AC380V±10% 50±0.5Hz (three-phase five wire system) |
Interior Size(W×D×H) | 500×320×300mm |
Exterior Size(W×D×H) | 900×800×750mm |
Standard Configurations | Stainless steel sample holder, one air-cooled xenon lamp, one portable irradiation meter |
Bandwidth Measurement (nm) | 280 ~ 800 |
Specimen Capacity (pcs) | 28 |
Specimen holder size (mm) | 80 × 15 |
Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |
Irradiation Source | 1 piece of 6500 W water-cooled Xenon Lamp with inner quartz and outer borosilicate filter |
Irradiance (W/㎡) | 100 ~ 1200 |
Black Panel Temperature | BPT 35 ~ 85 ℃ ± 2 °C |
Average Lamp Life | 1600 hours |
Relative Humidity Range | 50 ~ 98 % R.H ± 5 % RH |
Water Spray cycle | 1 ~ 9999 Hr 59 M, adjustable |
Internal dimensions | 500 × 760 × 500 mm |
Overall dimensions | 1200 × 1150 × 1480 mm |
Power Supply | AC 380 V 50 Hz |
Bandwidth Measurement (nm) | 300 - 420 |
Specimen Capacity (pcs) | 34 |
Specimen holder size (mm) | 80 × 15 |
Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |
Irradiation Source | 1 piece of 6500 W water-cooled Xenon Lamp with inner quartz and outer borosilicate filter |
Irradiance (W/㎡) | 35 ~ 150 |
Black Panel Temperature | BPT 35 ~ 85 ℃ ± 2 °C |
Average Lamp Life | 1600 hours |
Relative Humidity Range | 50 ~ 98 % R.H ± 5 % RH |
Water Spray cycle | 1 ~ 9999 Hr 59 M, adjustable |
Internal dimensions | 950 × 950 × 850 mm |
Overall dimensions | 1300 × 1420 × 1800 mm |
Power Supply | AC 380 V 50 Hz |
Bandwidth Measurement (nm) | 280 ~ 800 |
Specimen Capacity (pcs) | 28 |
Specimen holder size (mm) | 80 × 15 |
Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |
Irradiation Source | 1 piece of 6500 W water-cooled Xenon Lamp with inner quartz and outer borosilicate filter |
Irradiance (W/㎡) | 100 ~ 1200 |
Black Panel Temperature | BPT 35 ~ 85 ℃ ± 2 °C |
Average Lamp Life | 1600 hours |
Relative Humidity Range | 50 ~ 98 % R.H ± 5 % RH |
Water Spray cycle | 1 ~ 9999 Hr 59 M, adjustable |
Internal dimensions | 500 × 760 × 500 mm |
Overall dimensions | 1200 × 1150 × 1480 mm |
Power Supply | AC 380 V 50 Hz |