We manufacture different types of viscometers ranging from cone viscometers, rotational viscometers to ubbelohde viscometer, etc. that are widely used by laboratories to measure the viscosity of various fluid samples.
Measure position : | 1 |
Oil bath medium : | Polydimethylsiloxane |
Oil bath temperature range : | 10 °C to 180 °C |
Bath volume : | 8 L |
Measuring range : | 0.35 to 5000 mm2/s |
Measure position : | 2 (4 units measuring position at option) |
Bath volume : | 12 L |
Timing accuracy : | 0.01 s |
Accuracy : | ± 2 % (F.S) | ||||||||||||||||||
Temperature : | -1℃ to 150℃ (± 0.1℃) | ||||||||||||||||||
Spindle Details : |
| ||||||||||||||||||
Note : | rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s |
Measuring range : | 0.3 - 50000 mm2/s |
Measure position : | 2 |
Bath volume : | 25 L |
Timing accuracy : | 0.01 s |
Measuring range : | 0.3 - 50000 mm2/s |
Measure position : | 4 |
Bath volume : | 33 L |
Timing accuracy : | 0.01 s |
Measuring range : | 0.3 - 50000 mm2/s |
Measure position : | 6 |
Bath volume : | 41 L |
Timing accuracy : | 0.01 s |
Measuring range : | 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP |
Rotating speed : | 0.1 - 200 rpm |
Measuring Error (Newtonian liquid) : | ± 1.0 % full range |
Repeatability error (Newtonian liquid)) : | ± 0.5 % |
Viscosity Range : | LV: 1 to 2000000 mPa.s |
Rotation speed range : | 0.3 to 100 rpm (stepless) |
Spindles : | LV: (1#, 2#, 3#, 4# spindles) (0# is optional) |
Accuracy : | ± 1.0 % (of full range) |
Viscosity Range : | RV: 100 to 13000000 mPa.s |
Rotation speed range : | 0.3 to 100 rpm (stepless) |
Spindles : | RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
Accuracy : | ± 1.0 % (of full range) |
Viscosity Range : | HA: 200 to 26000000 mPa.s |
Rotation speed range : | 0.3 to 100 rpm (stepless) |
Spindles : | HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
Accuracy : | ± 1.0 % (of full range) |
Viscosity Range : | HB: 800 to 104000000 mPa.s |
Rotation speed range : | 0.3 to 100 rpm (stepless) |
Spindles : | HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
Accuracy : | ± 1.0 % (of full range) |
Viscosity Range : | LV: 1 to 6000000 mPa.s |
Rotation speed range : | 0.1 to 250 rpm |
Spindles : | (1#, 2#, 3#, 4# spindles) (0# is optional) |
Accuracy : | ± 1.0% (of full range) |
Viscosity Range : | RV: 100 to 40000000 mPa.s |
Rotation speed range : | 0.1 to 250 rpm |
Spindles : | (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
Accuracy : | ± 1.0% (of full range) |
Viscosity Range : | 3 to 1600000 M (mPa.s) |
Rotation speed range : | 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm |
Spindles : | 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml |
Rotor : | 18#,25#,31#,34# (standard configuration) |
Rotational speed range : | 0.3 to 100 rpm |
Standard Rotor : | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
Viscosity measurement range : | Rotor R2 to R7:100 to 4000 M (mPa.s) |
Standard Rotor Sample Dosage : | Rotor R1 to R7: 500 ml |
Rotational speed range : | 0.3 to 100 rpm |
Standard Rotor : | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
Viscosity measurement range : | Rotor R2 to R7:200 to 26 M (mPa.s) |
Standard Rotor Sample Dosage : | Rotor R1 to R7: 500 ml |
Measuring range : | 0.1 to 100,000 mPa.s |
Rotating speed : | 6/12/30/60 (r/min) |
Rotor : | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) : | ±1% |
Measuring range : | 0.1 to 2,000,000 mPa.s |
Rotating speed : | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor : | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) : | ±1% |
Measuring range : | 1 to 100000 mPa.s |
Rotating speed : | 3/6/12/30/60 (r/min) |
Rotor : | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) : | ±1% |
Measuring range : | 1 to 100000 mPa.s |
Rotating speed : | 3/6/12/30/60 (r/min) |
Rotor : | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) : | ±0.5% |
Measuring range : | 1 to 200000 mPa.s |
Rotating speed : | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
Rotor : | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) : | ±1% |
Measuring range : | 1 to 600000 mPa.s |
Rotating speed : | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor : | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) : | ±1% |
Measurement range : | 25 mPa.s to 1×10000000 mPa.s |
Rotors : | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed : | (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min |
Temperature control range : | 45 to 200°C |
Measurement range : | 100 mPa.s to 200000 mPa.s |
Rotors : | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed : | 5, 10, 20, 50 r/min |
Temperature control range : | Room temperature to 200°C |
Measurement range : | 100 mPa.s to 2000000 mPa.s |
Rotors : | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed : | 5, 10, 20, 50 r/min |
Temperature control range : | 45 to 200°C |
Viscosity Range : | 40.2 KU to 141.0 KU 32 g to 1099 g 27 to 5250 CP |
Rotation speed range : | 200±0.1 rpm |
Accuracy : | ± 3 % |
Repeatability : | ±1.5 % |