Viscometer LVM-A42 a floor standing rotational digital viscometer used to measure viscosity of liquid sample, semi-solid sample at specified shear rates. Adapted with new ARM technology, built-in Linus system, offers R2 to R7 Rotors (6 standard rotors), viscosity range 200 to 26 M (mPa.s) and 0.3 to 100 rpm rotation speed range (total of 998 speed options). Features a 5-inch color touch screen with visual display of variety of parameters and working conditions to guide users through test creation and data gathering for fast and easy viscosity measurements. It offers several advantages, like measuring multiple parameters, rich display content, convenient operation, intuitive reading, high measuring precision, stable rotational speed, strong anti-interference performance, showing the curve of shear rate, and viscosity, and so on. Each viscosity measuring range is automatically calibrated by a computer with high precision, and less errors.
Viscometer also known as rheometer is a measuring instrument used to determine a fluid's internal flow resistance or viscosity. It finds application in adhesive, latex, paint, cosmetics, ink, pulp, food, oil, starch, solvent, biochemical products and other industries.
| Measuring range | 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP |
| Rotating speed | 0.1 - 200 rpm |
| Measuring Error (Newtonian liquid) | ± 1.0 % full range |
| Repeatability error (Newtonian liquid)) | ± 0.5 % |
| Viscosity Range | LV: 1 to 2000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | LV: (1#, 2#, 3#, 4# spindles) (0# is optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | RV: 100 to 13000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | HA: 200 to 26000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | HB: 800 to 104000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | LV: 1 to 6000000 mPa.s |
| Rotation speed range | 0.1 to 250 rpm |
| Spindles | (1#, 2#, 3#, 4# spindles) (0# is optional) |
| Accuracy | ± 1.0% (of full range) |
| Viscosity Range | RV: 100 to 40000000 mPa.s |
| Rotation speed range | 0.1 to 250 rpm |
| Spindles | (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0% (of full range) |
| Viscosity Range | 3 to 1600000 M (mPa.s) |
| Rotation speed range | 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm |
| Spindles | 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml |
| Rotor | 18#,25#,31#,34# (standard configuration) |
| Rotational speed range | 0.3 to 100 rpm |
| Standard Rotor | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
| Viscosity measurement range | Rotor R2 to R7:100 to 4000 M (mPa.s) |
| Standard Rotor Sample Dosage | Rotor R1 to R7: 500 ml |
| Measuring range | 0.1 to 100,000 mPa.s |
| Rotating speed | 6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 0.1 to 2,000,000 mPa.s |
| Rotating speed | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 100000 mPa.s |
| Rotating speed | 3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 100000 mPa.s |
| Rotating speed | 3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±0.5% |
| Measuring range | 1 to 200000 mPa.s |
| Rotating speed | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 600000 mPa.s |
| Rotating speed | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 2 |
| Bath volume | 25 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 4 |
| Bath volume | 33 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 6 |
| Bath volume | 41 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.35 to 5000 mm2/s |
| Measure position | 2 (4 units measuring position at option) |
| Bath volume | 12 L |
| Timing accuracy | 0.01 s |
| Measure position | 1 |
| Oil bath medium | Polydimethylsiloxane |
| Oil bath temperature range | 10 °C to 180 °C |
| Bath volume | 8 L |
| Accuracy | ± 2 % (F.S) | ||||||||||||||||||
| Temperature | -1℃ to 150℃ (± 0.1℃) | ||||||||||||||||||
| Spindle Details |
|
||||||||||||||||||
| Note | rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s |