Ask An Expert
The rotational Viscometer LVM-C11 with stylish and modern technology, measures viscosity very quickly and accurately. It does measure & save 30 pcs test data. It is used in any area that requires the study of flow of liquid properties. They are handheld, user-friendly, and portable in nature.
Viscometer is used to measure viscosity of fluids, fluids under high melting temperature such as paints, coatings, cosmetics, inks, paper pulp, food, oil, starch, solvent-based glue, latex, and other biochemical products.
| Measuring range | 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP |
| Rotating speed | 0.1 - 200 rpm |
| Measuring Error (Newtonian liquid) | ± 1.0 % full range |
| Repeatability error (Newtonian liquid)) | ± 0.5 % |
| Viscosity Range | LV: 1 to 2000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | LV: (1#, 2#, 3#, 4# spindles) (0# is optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | RV: 100 to 13000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | HA: 200 to 26000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | HB: 800 to 104000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | LV: 1 to 6000000 mPa.s |
| Rotation speed range | 0.1 to 250 rpm |
| Spindles | (1#, 2#, 3#, 4# spindles) (0# is optional) |
| Accuracy | ± 1.0% (of full range) |
| Viscosity Range | RV: 100 to 40000000 mPa.s |
| Rotation speed range | 0.1 to 250 rpm |
| Spindles | (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0% (of full range) |
| Viscosity Range | 3 to 1600000 M (mPa.s) |
| Rotation speed range | 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm |
| Spindles | 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml |
| Rotor | 18#,25#,31#,34# (standard configuration) |
| Rotational speed range | 0.3 to 100 rpm |
| Standard Rotor | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
| Viscosity measurement range | Rotor R2 to R7:100 to 4000 M (mPa.s) |
| Standard Rotor Sample Dosage | Rotor R1 to R7: 500 ml |
| Rotational speed range | 0.3 to 100 rpm |
| Standard Rotor | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
| Viscosity measurement range | Rotor R2 to R7:200 to 26 M (mPa.s) |
| Standard Rotor Sample Dosage | Rotor R1 to R7: 500 ml |
| Measuring range | 0.1 to 100,000 mPa.s |
| Rotating speed | 6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 0.1 to 2,000,000 mPa.s |
| Rotating speed | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 100000 mPa.s |
| Rotating speed | 3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 200000 mPa.s |
| Rotating speed | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 600000 mPa.s |
| Rotating speed | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 2 |
| Bath volume | 25 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 4 |
| Bath volume | 33 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 6 |
| Bath volume | 41 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.35 to 5000 mm2/s |
| Measure position | 2 (4 units measuring position at option) |
| Bath volume | 12 L |
| Timing accuracy | 0.01 s |
| Measure position | 1 |
| Oil bath medium | Polydimethylsiloxane |
| Oil bath temperature range | 10 °C to 180 °C |
| Bath volume | 8 L |
| Accuracy | ± 2 % (F.S) | ||||||||||||||||||
| Temperature | -1℃ to 150℃ (± 0.1℃) | ||||||||||||||||||
| Spindle Details |
|
||||||||||||||||||
| Note | rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s |