Ask An Expert

Portable Conductivity Meter LPCM-A10
Conductivity: {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}
Temperature: {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}
Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient: Linear
Portable Conductivity Meter LPCM-A11
Conductivity: {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}
TDS: {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}
Temperature: {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}
Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A12
Conductivity: {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}
Salinity: {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}
Temperature: {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}
Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A13
Conductivity: {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}
TDS: {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}
Salinity: {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}
Resistivity: {"Resistivity range":"0.00 to 20 M\u03a9","Resistivity accuracy":"\u00b11% F.S","Resistivity resolution":"0.01, 0.1, 1"}

 Enquiry Now