Biosafety Cabinet Class II A2 LBS2-A21 is designed with UV life indicator and ULPA Filter, Two in number, 99.999 % efficiency at 0.12 um. Offers maximum opening of 420 mm (17 inch) and tested opening of safety height 200 mm (8 inch). Incorporated with interlock function for blower and front window, UV lamp and front window, UV lamp and blower and LED lamp. Built in with foot switch to avoid airflow turbulence caused by arm movement, motorized front window of two layered laminated toughened glass and anti UV, UV lamp for most efficient decontamination and remote control with all functions for easier and convenient operation. Features airflow system of 30 % air exhaust and 70 % air recirculation and three protection such as sample, environment and operator.
Specifications
Tested Opening | Safety height of 200 mm (8 inch) |
Maximum Opening | 420 mm (17 inch) |
Inflow Velocity | 0.53 ± 0.025 m/s |
Down Flow Velocity | 0.33 ± 0.025 m/s |
ULPA Filter | Two, 99.999 % efficient at 0.12 um, filter life indicator |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Noise | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB |
UV Lamp | 30 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination |
Illuminating Lamp | 12 W×2 LED Lamp |
Illumination | ≥ 1000 Lux |
Consumption | 800 W |
Waterproof Sockets | Two, total load of two sockets: 500 W |
Display | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. |
Control System | Microprocessor |
Airflow System | 70 % air recirculation, 30 % air exhaust |
Visual and audio alarm | Filter replacement, front window at unsafe height, abnormal airflow velocity |
Material | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating |
Work Surface Height | 750 mm |
Caster | Foot master caster |
Power Supply | AC220V±10 %, 50/60 hz; 110V ± 10 %, 60 hz |
Internal Size (W×D×H) | 1150×600×660 mm |
External Size (W×D×H) | 1300×750×2250 mm |
Package Size (W×D×H) | 1460×1050×1800 mm |
Gross Weight | 280 kg |
Features
Managed and monitored by an integrated microprocessor controller
Large LCD digital display for ease of monitoring all safety parameters
Incorporated with memory function in case of power-failure
Work zone made up of 304 stainless steel
Built in with time reserve function, automatic air speed adjustable with filter block and interlock function
Integrated with visual and audible alarm for abnormal airflow velocity, filter replacement, front window at unsafe height
Designed with universal caster with brake and leveling feet
Easy to use, operate and maintain
Easy to clean, corrosion resistant, stainless steel lining
Applications
Biosafety Cabinet Class II A2 is widely used in pathology, research laboratories, universities, colleges and hospitals. It is suitable to use for microbiology research in absence of volatile, toxic chemicals and radionuclide.
Standard Accessories
Sr. No | Name of the Accessory | Unit |
1. | Illumination LED Lamp | 2 |
2. | UV Lamp | 1 |
3. | Base Stand | 1 |
4. | Remote Control | 1 |
5. | Foot Switch | 1 |
6. | Drain Valve | 1 |
7. | Waterproof Sockets | 2 |
Optional Accessories
Electric Height Adjustable Base Stand
Request Quote
Tested Opening | Safety height of 200 mm (8 inch) |
Maximum Opening | 420 mm (17 inch) |
Inflow Velocity | 0.53 ± 0.025 m/s |
Down Flow Velocity | 0.33 ± 0.025 m/s |
ULPA Filter | Two, 99.999 % efficient at 0.12 um, filter life indicator |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Noise | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB |
UV Lamp | 30 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination |
Illuminating Lamp | 12 W×2 LED Lamp |
Illumination | ≥ 1000 Lux |
Consumption | 760 W |
Waterproof Sockets | Two, total load of two sockets: 500 W |
Display | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. |
Control System | Microprocessor |
Airflow System | 70 % air recirculation, 30 % air exhaust |
Visual and audio alarm | Filter replacement, front window at unsafe height, abnormal airflow velocity |
Material | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-vvbacteria powder coating |
Work Surface Height | 750 mm |
Caster | Foot master caster |
Power Supply | AC 220 V ± 10 %, 50/60 hz; 110 V ± 10 %, 60 hz |
Internal Size (W×D×H) | 940×600×660 mm |
External Size (W×D×H) | 1100×750×2250 mm |
Package Size (W×D×H) | 1220×1000×1840 mm |
Gross Weight | 243 kg |
Tested Opening | Safety height of 200 mm (8 inch) |
Maximum Opening | 500 mm (20 inch) |
Inflow Velocity | 0.53 ± 0.025 m/s |
Down Flow Velocity | 0.33 ± 0.025 m/s |
ULPA Filter | Two, 99.999 % efficient at 0.12 um, filter life indicator |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Noise | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB |
UV Lamp | 40 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination |
Illuminating Lamp | 16 W×2 LED Lamp |
Illumination | ≥ 1000 Lux |
Consumption | 900 W |
Waterproof Sockets | Two, total load of two sockets: 500 W |
Display | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. |
Control System | Microprocessor |
Airflow System | 70 % air recirculation, 30 % air exhaust |
Visual and audio alarm | Filter replacement, front window at unsafe height, abnormal airflow velocity |
Material | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating |
Work Surface Height | 750 mm |
Caster | Foot master caster |
Power Supply | AC 220 V ± 10 %, 50/60 hz; 110 V ± 10 %, 60 hz |
Internal Size (W×D×H) | 940×600×660 mm |
External Size (W×D×H) | 1350×600×660 mm |
Package Size (W×D×H) | 1630×1000×1820 mm |
Gross Weight | 315 kg |
Tested Opening | Safety height of 200 mm (8 inch) |
Maximum Opening | 550 mm (22 inch) |
Inflow Velocity | 0.53 ± 0.025 m/s |
Down Flow Velocity | 0.33 ± 0.025 m/s |
ULPA Filter | Two, 99.999 % efficient at 0.12 um, filter life indicator |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Noise | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB |
UV Lamp | 40 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination |
Illuminating Lamp | 16 W×2 LED Lamp |
Illumination | ≥ 1000 Lux |
Consumption | 900 W |
Waterproof Sockets | Two, total load of two sockets: 500 W |
Display | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. |
Control System | Microprocessor |
Airflow System | 70 % air recirculation, 30 % air exhaust |
Visual and audio alarm | Filter replacement, front window at unsafe height, abnormal airflow velocity |
Material | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating |
Work Surface Height | 750 mm |
Caster | Foot master caster |
Power Supply | AC220V±10 %, 50/60 hz; 110V ± 10 %, 60 hz |
Internal Size (W×D×H) | 1150×600×660 mm |
External Size (W×D×H) | 1700×600×660 mm |
Package Size (W×D×H) | 2000×950×1820 mm |
Gross Weight | 395 kg |
Tested Opening | Safety height of 200 mm (8 inch) |
Maximum Opening | 370 mm (15 inch) |
Inflow Velocity | 0.53 ± 0.025 m/s |
Down Flow Velocity | 0.33 ± 0.025 m/s |
HEPA Filter | Two, 99.999% efficient at 0.3 um, filter life indicator |
Front Window | Motorized, toughened glass, anti UV |
Noise | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB |
UV Lamp | 15 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination |
Illuminating Lamp | 8 W×2 LED Lamp |
Illumination | ≥ 1000 Lux |
Consumption | 500 W |
Sockets | Two, total load of two sockets: 500 W |
Display | LCD display |
Control System | Microprocessor |
Airflow System | 70 % air recirculation, 30 % air exhaust |
Visual and audio alarm | Filter replacement, window over height, abnormal air flow velocity |
Material | Work Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria powder coating |
Work Surface Height | 750 mm with optional base |
Power Supply | AC 220 V ± 10 %, 50/60 Hz; 110 V ± 10 %, 60 Hz |
Internal Dimension (W×D×H) | 600×500×540 mm |
External Dimension (W×D×H) | 700×650×1230 mm |
Packaging Dimension without base stand (W×D×H) | Wooden Box: 860×800×1450 mm Carton: 820×760×1430 mm |
Packaging Dimension with base stand (W×D×H) | Wooden Box: 860×960×1450 mm |
Gross Weight without base stand | Wooden Box: 164 kg Cartoon: 121 kg |
Gross Weight with base stand | 196 kg |
External dimension | 680 × 410 × 1160 mm |
Internal dimension | 630 × 375 × 615 mm |
Work surface height | NA |
Display | LED |
Airflow velocity | Average 0f 0.3 to 0.5 m/s, air speed adjusted |
Material main body | Cold rolled steel with anti- bacteria power coating |
Material work table | NA |
Pre- filter | Polyester fiber, washable |
HEPA Filter | 99.999% efficiency at 0.3 µm |
Noise | < 65 dB |
Front window | NA |
Max opening | NA |
Illuminating lamp | Fluorescent lamp 8 W × 1 |
UV Lamp | 15 W × 1 Emission of 253.7 nanometer |
Packing dimension | 840 × 560 × 1380 mm |
Power consumption | 160 W |
Power supply | AC 220V ±10%, 50/60 Hz, 110V±10%, 60Hz |
Gross weight | 50 kg |
External dimension | 802 × 650 × 1550 mm |
Internal dimension | 800 × 530 × 540 mm |
Work surface height | 660 mm |
Display | LED |
Airflow velocity | Average 0f 0.3 to 0.5 m/s, air speed adjusted |
Material main body | Cold rolled steel with anti- bacteria power coating |
Material work table | 304 stainless steel |
Pre- filter | Polyester fiber, washable |
HEPA Filter | 99.999% efficiency at 0.3 µm |
Noise | < 65 dB |
Front window | Manual, 5 mm touchened glass, anti UV |
Max opening | 490 mm |
Illuminating lamp | LED lamp 8 W × 1 |
UV Lamp | 18 W × 1 Emission of 253.7 nanometer |
Packing dimension | 960 × 800 × 1800 mm |
Power consumption | 350 W |
Power supply | AC 220V ±10%, 50/60 Hz, 110V±10%, 60Hz |
Gross weight | 116 kg |
External dimension | 1040 × 615 × 1770 mm |
Internal dimension | 940 × 540 × 545 mm |
Work surface height | 750 mm |
Display | LED |
Airflow velocity | Average 0f 0.3 to 0.5 m/s, air speed adjusted |
Material main body | Cold rolled steel with anti- bacteria power coating |
Material work table | 304 stainless steel |
Pre- filter | Polyester fiber, washable |
HEPA Filter | 99.999% efficiency at 0.3 µm |
Noise | < 65 dB |
Front window | Manual, 5 mm touchened glass, anti UV |
Max opening | 310 mm |
Illuminating lamp | LED lamp 12 W × 1 |
UV Lamp | 18 W × 1 Emission of 253.7 nanometer |
Packing dimension | 1200 × 850 × 1360 mm |
Power consumption | 350 W |
Power supply | AC 220V ±10%, 50/60 Hz, 110V±10%, 60Hz |
Gross weight | 131 kg |
External dimension | 1440 × 615 × 1770 mm |
Internal dimension | 1340 × 540 × 545 mm |
Work surface height | 750 mm |
Display | LED |
Airflow velocity | Average 0f 0.3 to 0.5 m/s, air speed adjusted |
Material main body | Cold rolled steel with anti- bacteria power coating |
Material work table | 304 stainless steel |
Pre- filter | Polyester fiber, washable |
HEPA Filter | 99.999% efficiency at 0.3 µm |
Noise | < 65 dB |
Front window | Manual, 5 mm touchened glass, anti UV |
Max opening | 310 mm |
Illuminating lamp | LED lamp 16 W × 1 |
UV Lamp | 30 W × 1 Emission of 253.7 nanometer |
Packing dimension | 1600 × 850 × 1360 mm |
Power consumption | 600 W |
Power supply | AC 220V ±10%, 50/60 Hz, 110V±10%, 60Hz |
Gross weight | 174 kg |
External dimension (W x L x H) | 1590 x 800 x 1800 mm |
Internal dimension (W x L x H) | 1430 x 620 x 575 mm |
Illumination | ≥ 300 lux |
Purification rank (ISO 14644-1 Std.) | 100 |
Air flow | |
Noise | ≤ 61 dB |
Power | 240 W |
Power supply | 220 V/50 Hz |
LED standard | 18X1 |
Filtration efficiency (% @ 0.3μm) | |
HEPA size (W x H x D) | 610 x 1470 x 69 mm |
Average velocity | 0.25-0.4 m/s |
Net Weight | 170 kg |
External dimension (W x L x H) | 1340 x 800 x 1800 mm |
Internal dimension (W x L x H) | 1180 x 620 x 575 mm |
Illumination | ≥ 300 lux |
Purification rank (ISO 14644-1 Std.) | 100 |
Air flow | |
Noise | ≤ 61 dB |
Power | 230 W |
Power supply | 220 V/50 Hz |
LED standard | 13x1 |
Filtration efficiency (% @ 0.3μm) | |
HEPA size (W x H x D) | 610 x 1220 x 69 mm |
Average velocity | 0.25-0.4 m/s |
Net Weight | 150 kg |
External dimension (W x L x H) | 1090 x 800 x 1800 mm |
Internal dimension (W x L x H) | 930 x 620 x 575 mm |
Illumination | ≥ 300 lux |
Purification rank (ISO 14644-1 Std.) | 100 |
Air flow | |
Noise | ≤ 61 dB |
Power | 220 W |
Power supply | 220 V/50 Hz |
LED standard | 9x1 |
Filtration efficiency (% @ 0.3μm) | |
HEPA size (W x H x D) | 610 x 970 x 69 mm |
Average velocity | 0.25-0.4 m/s |
Net Weight | 130 kg |
External dimension (W x L x H) | 960 x 780 x 1580 mm |
Internal dimension (W x L x H) | 930 x 600 x 650 mm |
Illumination | ≥ 300 lux |
Purification rank (ISO 14644-1 Std.) | 100 |
Air flow | 600-950 m³⁄h |
Noise | ≤ 65 dB |
Power | 290 W |
Power supply | 220 V/50 Hz |
LED standard | 9x1 |
Filtration efficiency (% @ 0.3μm) | 99.99 |
HEPA size (W x H x D) | |
Average velocity | 0.3-0.5 m/s |
Net Weight | 120 kg |
Internal dimension ( W x D x H ) | 900 x 595 x 560 mm |
External dimension ( W x D x H ) | 1000 x 705 x 1770 mm |
UV lamp | 20 W x 2 |
Illumination lamp | 40 W x 1 |
Work surface height | 750 mm |
Work table material | 304 stainless steel |
Main body material | Cold rolled steel with anti-bacteria powder coating |
Front and side window material | 5 mm toughened glass window, anti-UV |
Front and side window orientation | Manual |
Maximum window opening | 320 mm |
Pre-filter | Washable Polyester fiber |
HEPA filter | HEPA Filter With 99.999% Efficiency at 0.3 µm |
Airflow velocity ( speed adjustable ) | 0.3 m/s to 0.5 m/s |
Illumination | ≥ 1000 Lux |
UV lamp emission | 253.7 nm |
UV lamp timer ( preset ) | 90 mins |
Shelf with IV bar material | Stainless steel |
Shelf with IV bar dimension ( W x D x H ) | 502 x 150 x 50 mm |
Caster | Feet levelling |
Power supply | AC 220 V ; 50 Hz / 60 Hz AC 110 V ; 60 Hz |
Power consumption | 300 W |
Weight | 150 kg |
Internal dimension ( W x D x H ) | 700 x 595 x 550 mm |
External dimension ( W x D x H ) | 800 x 700 x 1770 mm |
UV lamp | 20 W x 1 |
Illumination lamp | LED 8 W x 2 |
Work surface height | 750 mm |
Work table material | 304 stainless steel |
Main body material | Cold rolled steel with anti-bacteria powder coating |
Front and side window material | 5 mm toughened glass window, anti-UV |
Front and side window orientation | Motorized |
Maximum window opening | 300 mm |
Pre-filter | Washable Polyester fiber |
HEPA filter | HEPA Filter With 99.999% Efficiency at 0.3 µm |
Airflow velocity ( speed adjustable ) | 0.3 m/s to 0.5 m/s |
Illumination | ≥ 1000 Lux |
UV lamp emission | 253.7 nm |
UV lamp timer ( preset ) | 90 mins |
Shelf with IV bar material | Stainless steel |
Shelf with IV bar dimension ( W x D x H ) | 502 x 150 x 50 mm |
Caster | Feet levelling |
Power supply | AC 220 V ; 50 Hz / 60 Hz AC 110 V ; 60 Hz |
Power consumption | 400 W |
Weight | 130 kg |
Internal dimension ( W x D x H ) | 1100 x 595 x 550 mm |
External dimension ( W x D x H ) | 1200 x 700 x 1770 mm |
UV lamp | 30 W x 1 |
Illumination lamp | LED 12 W x 2 |
Work surface height | 750 mm |
Work table material | 304 stainless steel |
Main body material | Cold rolled steel with anti-bacteria powder coating |
Front and side window material | 5 mm toughened glass window, anti-UV |
Front and side window orientation | Motorized |
Maximum window opening | 300 mm |
Pre-filter | Washable Polyester fiber |
HEPA filter | HEPA Filter With 99.999% Efficiency at 0.3 µm |
Airflow velocity ( speed adjustable ) | 0.3 m/s to 0.5 m/s |
Illumination | ≥ 1000 Lux |
UV lamp emission | 253.7 nm |
UV lamp timer ( preset ) | 90 mins |
Shelf with IV bar material | Stainless steel |
Shelf with IV bar dimension ( W x D x H ) | 502 x 150 x 50 mm |
Caster | Feet levelling |
Power supply | AC 220 V ; 50 Hz / 60 Hz AC 110 V ; 60 Hz |
Power consumption | 600 W |
Weight | 170 kg |
Internal dimension ( W x D x H ) | 1200 x 595 x 550 mm |
External dimension ( W x D x H ) | 1300 x 700 x 1770 mm |
UV lamp | 30 W x 1 |
Illumination lamp | LED 12 W x 2 |
Work surface height | 750 mm |
Work table material | 304 stainless steel |
Main body material | Cold rolled steel with anti-bacteria powder coating |
Front and side window material | 5 mm toughened glass window, anti-UV |
Front and side window orientation | Motorized |
Maximum window opening | 300 mm |
Pre-filter | Washable Polyester fiber |
HEPA filter | HEPA Filter With 99.999% Efficiency at 0.3 µm |
Airflow velocity ( speed adjustable ) | 0.3 m/s to 0.5 m/s |
Illumination | ≥ 1000 Lux |
UV lamp emission | 253.7 nm |
UV lamp timer ( preset ) | 90 mins |
Shelf with IV bar material | Stainless steel |
Shelf with IV bar dimension ( W x D x H ) | 502 x 150 x 50 mm |
Caster | Feet levelling |
Power supply | AC 220 V ; 50 Hz / 60 Hz AC 110 V ; 60 Hz |
Power consumption | 600 W |
Weight | 180 kg |
Exhaust Volume | 465 m3/h (273 cfm) |
Tested Opening | Safety Height 200 mm (8 inches) |
Max Opening | 440 mm (17 inches) |
Internal Work Area, Space | 0.73 m3 |
Inflow Velocity | 0.53 m/s |
Down Flow Velocity | 0.33 m/s |
Air Supply Filter | ULPA filter, efficiency > 99.999 % for particle size at 0.3 µm |
Exhaust Filter | 2 pieces HEPA filters, efficiency > 99.999 % for particle size at 0.3 µm Filter life indicator and filter working time indicator |
Alarm | Abnormal airflow velocity; Filter replacement; Front window at unsafe height |
Noise | EN 12469 ≤ 58 dB/NSF 49 ≤ 61 dB |
Water And Gas Tap | Water Tap×1, Gas tap×1 |
UV Lamp | 30 W×1 Emission of 253.7 nanometres for most efficient decontamination UV life indicator |
LED lamp | 16 W×2 |
Illumination | ≥ 1000 lux |
Consumption | 900 W |
Waterproof Socket | Two; Total load of two sockets: ≤ 500 W |
Display | LCD Display |
Control System | Microprocessor |
Humidity And Temperature | Humidity and temperature can be displayed on the control panel |
Material | Work Area:304 stainless steel Main Body: Cold- rolled steel with anti- bacteria powder coating |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Caster | Foot master Caster |
Power Supply | AC 220 V ± 10 %, 50/60 Hz; 110 V ± 10 %, 60Hz |
Internal Size (W×D×H) | 1220×600×630 mm |
External Size (W×D×H) | 1380×760×2100 mm |
Package Size (W×D×H) | 1540×910×2280 mm |
Gross Weight | 371 kg |
Exhaust Volume | 347 m3/h (204 cfm) |
Tested Opening | Safety Height 200 mm (8 inches) |
Max Opening | 440 mm (17 inches) |
Internal Work Area, Space | 0.55 m3 |
Inflow Velocity | 0.53 m/s |
Down Flow Velocity | 0.33 m/s |
Air Supply Filter | ULPA filter, efficiency > 99.999 % for particle size at 0.12 µm |
Exhaust Filter | 2 pieces HEPA filters, efficiency > 99.999 % for particle size at 0.3 µm Filter life indicator and filter working time indicator |
Alarm | Abnormal airflow velocity; Filter replacement; Front window at unsafe height |
Noise | EN 12469 ≤ 58 dB/NSF 49 ≤ 61 dB |
Water And Gas Tap | Water Tap×1, Gas tap×1 |
UV Lamp | 18 W×1 Emission of 253.7 nanometres for most efficient decontamination UV life indicator |
LED lamp | 12 W×2 |
Illumination | ≥ 1000 lux |
Consumption | 700 W |
Waterproof Socket | Two; Total load of two sockets: ≤ 500 W |
Display | LCD Display |
Control System | Microprocessor |
Humidity And Temperature | Humidity and temperature can be displayed on the control panel |
Material | Work Area:304 stainless steel Main Body: Cold- rolled steel with anti- bacteria powder coating |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Caster | Foot master Caster |
Power Supply | AC 220 V ± 10 %, 50/60 Hz; 110 V ± 10 %, 60Hz |
Internal Size (W×D×H) | 910×600×630 mm |
External Size (W×D×H) | 1087×760×2100 mm |
Package Size (W×D×H) | 1080×910×2280 mm |
Gross Weight | 320 kg |
External dimension | 1300 × 820 × 2040 mm |
Internal dimension | 1200 × 500 × 570 mm |
Work surface height | 750 mm |
Display | LCD |
Airflow velocity | Average of 0.3 to 0.5 m/s |
Material main body | Cold rolled steel with anti- bacteria power coating |
Material work table | 304 stainless steel |
Side and Front windows | 5 mm touchened glass, anti UV |
Pre- filter | Polyester fiber, washable |
HEPA Filter | 99.999% efficiency at 0.3 µm |
Noise | < 65 dB |
Front window | Motorized |
Max opening | 430 mm |
Illuminating lamp | LED lamp 12 W × 1 |
UV Lamp | 30 W × 1 Emission of 253.7 nanometer |
Caster | Universal caster with levelling feet |
Waterproof socket | Two, total load ≤ 500 W |
Packing dimension | 1450 × 1060 × 1650 mm |
Power consumption | 400 W |
Power supply | AC 220V ±10%, 50/60 Hz, 110V±10%, 60Hz |
Gross weight | 254 kg |
External dimension | 1800 × 820 × 2070 mm |
Internal dimension | 1700 × 500 × 570 mm |
Work surface height | 750 mm |
Display | LCD |
Airflow velocity | Average of 0.3 to 0.5 m/s |
Material main body | Cold rolled steel with anti- bacteria power coating |
Material work table | 304 stainless steel |
Side and Front windows | 5 mm touchened glass, anti UV |
Pre- filter | Polyester fiber, washable |
HEPA Filter | 99.999% efficiency at 0.3 µm |
Noise | < 65 dB |
Front window | Motorized |
Max opening | 430 mm |
Illuminating lamp | LED lamp 16 W × 2 |
UV Lamp | 30 W × 1 Emission of 253.7 nanometer |
Caster | Universal caster with levelling feet |
Waterproof socket | Two, total load ≤ 500 W |
Packing dimension | 1950 × 1060 × 1600 mm |
Power consumption | 500 W |
Power supply | AC 220V ±10%, 50/60 Hz, 110V±10%, 60Hz |
Gross weight | 328 kg |