The colorimeter LCC-A13 offers the specular component excluded SCE measuring condition, specially designed for color measurement of powders, pasty materials, colloids and highly reflective materials. Both the yellowness & whiteness measurement can be done using this colorimeter. This colorimeter gives ultra stable performance throughout the operations.
This colorimeter has major applications in dye and painting, decoration, Biotechnology, pharmacy food, printing industries for measurement of pasty materials & powders.
| Color measurement method | Color card |
| Illumination system | 8°/d (diffusion illumination), SCI (spectral components included) |
| Display mode | Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values Color difference values: △(L × a × b),△(L × C × h) Whiteness values: hunter whiteness, Ganz whiteness Yellowness value: YI |
| Display screen | 2.4 inch LCD display screen |
| Illumination system | 8°/d (diffusion illumination), SCI (spectral components included) |
| Display mode | Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values Color difference values: △(L × a × b),△(L × C × h) Whiteness values: hunter whiteness, Ganz whiteness Yellowness value: YI |
| Display screen | 2.4 inch LCD display screen |
| Measuring calibration | About 8 mm |
| Characteristic function | Camera viewing system for measurement |
| Illumination system | 8°/d (diffusion illumination), SCI (spectral components included) |
| Display mode | Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values Color difference values: △(L × a × b),△(L × C × h) Whiteness values: hunter whiteness, Ganz whiteness Yellowness value: YI |
| Display screen | 2.4 inch LCD display screen |
| Illumination system | 8°/d (diffusion illumination), SCI (spectral components included) |
| Display mode | Colorimetric values: L × a × b,L × C × h,△E × abXYZ,relative RGB values Color difference values: △(L × a × b),△(L × C × h) |
| Display screen | 2.4 inch LCD display screen |
| Measuring calibration | About 8 mm |
| Illumination | Di / 8 (diffusion illumination, 8° viewing), SCI |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Sensor | Sensor array |
| Illumination | Di / 8 (diffusion illumination, 8° viewing), SCI |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Sensor | Sensor array |
| Illumination | Di / 8 (diffusion illumination, 8° viewing), SCI |
| Size of integrated sphere | 40 mm, avian diffused reflection surface coating |
| Illumination light source | CLED |
| Sensor | Sensor array |
| Light source | CIE-A, CIE-C, CIE-D65 |
| Standards | ASTM D1003/D1044 & ISO13468/ISO14782 |
| Parameters | HAZE, Transmittance(T) |
| Spectral response | CIE Luminosity function y |
| Light source | CIE-A,CIE-C,CIE-D65 Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84 |
| Standards | ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164 |
| Parameters | HAZE, Transmittance(T),Spectral Transmittance Whiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby) Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73) Tint(ASTM E313-00), Metamerism Index, Milm APHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00) |
| Spectral response | CIE Luminosity function y |
| Wavelength Range | 420 to 660 nm |
| Filter | 420 nm , 470 nm ,530 nm ,620 nm , 660 nm |
| High stability and reproducibility | ± 5 nm |
| Economy | Consumes only 1.5ml of reagent |