Ask An Expert
Friability Tester LTFT-A11 is a benchtop tablet friability tester with single path, and synchronously running two drums. The number of turns and rotating speed of friability tester is in accordance with international standards, to enable convenient dispensing, modifications and operations. For research and quality purpose, high accuracy is achieved by testing speed and circle number in this friability tester.
Used to detect friability, abrasion of non-coated tablets, coated tablets, capsules, mechanical stability, and collision resistance across pharmaceutical, medicine, and cosmetics for quality and research purpose.
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 100 turns can be set arbitrarily |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 5 to 900 turns can be set arbitrarily |
| Number of cylinder | 1 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Counting mode | 10 to 900 turns can be set arbitrarily |
| No of vessels | 1 |
| No of poles | 1 |
| Position of vessels and poles | One vessel and one pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 3 |
| No of poles | 3 |
| Position of vessels and poles | Three vessel and three pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| Head part movement | Electrically turn over |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| Head part movement | Manually turn over |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| Head part movement | Electrically turn over |
| No of vessels | 8 |
| No of poles | 8 |
| Position of vessels and poles | Four vessels and four poles in front and others at back |
| Head part movement | Electrically turn over |
| No of vessels | 12 |
| No of poles | 12 |
| Position of vessels and poles | Six vessels and six poles in front and other six poles and vessels at back |
| Head part movement | Electrically (automatic) turn over |
| Number of basket lifting set | 1 set |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Number of basket lifting set | 2 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Number of basket lifting set | 3 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Hardness measurement range | 2 to 196 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 20 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | No |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | No |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | Yes |
| Diameter of counting plate | 400 mm |
| Hole No. of counting slide/range | 5 to 100 (optional) |
| Production efficiency | 10 to 20 vials/ min |
| Rate of Bottles | 36 bottles/ minute |
| Maximum pressure | 60 KN |
| Maximum diameter Tablet | 25 mm |
| Maximum depth of filling | 16 mm |
| Maximum thickness of tablet | 10 mm |
| Maximum pressure | 50 KN |
| Maximum diameter Tablet | 20 mm |
| Maximum depth of filling | 12 mm |
| Maximum thickness of tablet | 6 mm |
| Maximum pressure | 15 KN |
| Maximum diameter Tablet | 12 mm |
| Maximum depth of filling | 11 mm |
| Maximum thickness of tablet | 6 mm |
| Material Stainless | 316 L Stainless Steel |
| Automatic Grade | Semi-Automatic |
| Power Source | Pneumatic |
| Filling Head | Single Head or Double Head or Customized |
| Disc | Diameter 100 mm |
| Funnel Outer Diameter | Outer diameter 155 mm |
| Funnel Inner Diameter | 145 mm |
| Test Sample | Surfactant Powder and Particles, non-agglomerated powder |
| Work Station | 1 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
| Work Station | 2 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
| Work Station | 3 |
| Sample Volume | ≤ 100 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |