Disintegration tester LDIT-A12 is adopted with high-precision digital electronic sensor, ensures quality precision and accuracy of the water bath temperature without need for calibration. Equipped with two to three sets of basket, conducts independent disintegration experiments. The default setting for lifting time of the basket is 15 mins, can manually set the other time value as per the experimental need.
Used for detection of rate of disintegration of solids such as tablets, capsules, pills in required /set (prescriptive) conditions at pharmaceutical industry.
| Number of basket lifting set | 1 set |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Number of basket lifting set | 2 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| No of vessels | 1 |
| No of poles | 1 |
| Position of vessels and poles | One vessel and one pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 3 |
| No of poles | 3 |
| Position of vessels and poles | Three vessel and three pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| Head part movement | Electrically turn over |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| Head part movement | Manually turn over |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| Head part movement | Electrically turn over |
| No of vessels | 8 |
| No of poles | 8 |
| Position of vessels and poles | Four vessels and four poles in front and others at back |
| Head part movement | Electrically turn over |
| No of vessels | 12 |
| No of poles | 12 |
| Position of vessels and poles | Six vessels and six poles in front and other six poles and vessels at back |
| Head part movement | Electrically (automatic) turn over |
| Hardness measurement range | 2 to 196 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 20 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | No |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | No |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | Yes |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 100 turns can be set arbitrarily |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 20 to 100 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 5 to 900 turns can be set arbitrarily |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 5 to 900 turns can be set arbitrarily |
| Number of cylinder | 1 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Counting mode | 10 to 900 turns can be set arbitrarily |
| Diameter of counting plate | 400 mm |
| Hole No. of counting slide/range | 5 to 100 (optional) |
| Production efficiency | 10 to 20 vials/ min |
| Rate of Bottles | 36 bottles/ minute |
| Maximum pressure | 60 KN |
| Maximum diameter Tablet | 25 mm |
| Maximum depth of filling | 16 mm |
| Maximum thickness of tablet | 10 mm |
| Maximum pressure | 50 KN |
| Maximum diameter Tablet | 20 mm |
| Maximum depth of filling | 12 mm |
| Maximum thickness of tablet | 6 mm |
| Maximum pressure | 15 KN |
| Maximum diameter Tablet | 12 mm |
| Maximum depth of filling | 11 mm |
| Maximum thickness of tablet | 6 mm |
| Material Stainless | 316 L Stainless Steel |
| Automatic Grade | Semi-Automatic |
| Power Source | Pneumatic |
| Filling Head | Single Head or Double Head or Customized |
| Disc | Diameter 100 mm |
| Funnel Outer Diameter | Outer diameter 155 mm |
| Funnel Inner Diameter | 145 mm |
| Test Sample | Surfactant Powder and Particles, non-agglomerated powder |
| Work Station | 1 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
| Work Station | 2 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
| Work Station | 3 |
| Sample Volume | ≤ 100 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |