Ask An Expert
Ash Content Tester LACT-A10 is the device composed of muffle furnace, temperature controller and electric heating plate. It is small size and needs less land with special fire-resistant material and heating components. The heating time is short and it has a long lifetime. It used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and petroleum products.
Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.
| Calorimeter type | Isoperibol |
| Temperature range | 5 to 40°C |
| Measurement range | 5 to 40 MJ/ kg |
| Operation Mode | The outer barrel temperature is constant |
| Calorimeter type | Isoperibol |
| Temperature range | 5 to 40°C |
| Measurement range | 5 to 40 MJ/ kg |
| Operation Mode | A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode |
| Calorimeter type | Isoperibol |
| Oxygen filling | Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
| Bomb volume | 250 ml |
| Analysis time | < 8 min full test process: <10 min |
| Calorimeter type | Isoperibol |
| Oxygen filling | Semi-automatic |
| Bomb volume | 282 ml |
| Analysis time | 15 to 25 min |
| Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
| Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON |
| Measuring Range For Ethanol | E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON |
| Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN Cetane index: 20 to 80/CI |
| Measurement item | motor gasoline and diesel |
| measurement unit of octane is ON | 40 to 120 |
| Permissible error of octane | ± 0.5 max |
| Fluctuate range of octane | ± 0.2 max |
| Graduated flask | 100 ml,50 ml |
| Conical flask | 100ml |
| Separatory funnel | 250ml |
| Ambient temperature | (-10 )°C to 35 °C |
| Ambient temperature | ≤ 35 °C |
| Relative humidity | ≤ 85 % |
| Precision of titration tube | Scale division is 0.02 ml |
| Total power consumption | ≤ 1200 W |
| Measurement range | ≥0.05 mg KOH/g |
| Potential measurement range | 0 to 1800.0 mV |
| Burette volume | 10 mL |
| Minimum titration volume | 0.001 ml |
| Volumetric analysis | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml |
| Automatic acid titration | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH |
| Automatic potential control | Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV |
| Ambient temperature | 0 ~ 35 ℃ |
| Measurement range | Room temperature ~ 150°C |
| Stirring speed | 0 ~ 1200 r / min |
| Heating power | 25 W |
| Interior Dimension | 360 × 250 × 545 mm |
| Temperature controlling accuracy | ≤ 0.5 ℃ |
| Temperature controlling range | Room temperature ~ 200 ℃ |
| Power supply for illumination | 5 V |
| Power of motor | 2 kW |
| Ambient temperature | ≤ 35 °C |
| Relative humidity | ≤ 85 % |
| Temperature range | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
| Aperture of ignition device | 0.8 mm |
| Ambient temperature | 10 °C ~ 40 °C |
| Relative humidity | ≤ 80 % |
| Measurement Range | Ambient Temperature ~ 250 °C |
| Flash Point | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C |
| Ambient temperature | 10 °C ~ 40 ℃ |
| Relative humidity | ≤ 80 % |
| Ignition Mode | electron igniter / gas flame |
| Temperature range | Room Temperature ~ 300 ℃ |
| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Timing range | 1 s to 9 min 59 s |
| Temperature controlling range | Room temperature to 99.9 °C |
| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Temperature controlling range | Room temperature to 99.9 °C |
| Temperature controlling accuracy | ± 1 °C |
| Cubage of bath | Ф300 × 380 mm |
| Temperature controlling range | 0 °C ~ 100 °C |
| Temperature controlling accuracy | ± 0.2 °C |
| Temperature sensor | Industrial platinum resistance, Pt100 |
| Heating power | 2 kW |
| Cooling power | 0.5 kW |
| Steam temperature | 0 to 400℃ |
| Oven temperature | 0 to 500℃ |
| Ambient temperature | -10°C to 35°C |
| Relative humidity | ≤ 85 % |
| Thermometer | Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C |
| Scale division | 0.1 ℃ |
| Graduated flasks | 100 ml |
| Scale division of graduated flask | 1ml |
| Distillation flask | 125 ml |
| Ambient temperature | ≤ 35 °C |
| Graduated flasks | 100 ml |
| Distillation flask | 125 ml |
| Ambient temperature | ≤ 35 °C |
| Relative humidity | ≤ 85 % |
| Distillation flask | 125 mL |
| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Thermometer | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ |
| Graduated flasks | 10 ml and 100 ml |
| Scale division of graduated flask | 10 ml is 0.1 ml and 100 ml is 1 ml |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Graduated flasks | 100 ml |
| Scale division of graduated flask | 1 ml |
| Outer diameter of distillation flask | φ65 |
| Refrigeration tube | φ14 |
| Graduated flasks | 100 ml |
| Distillation flask | 125 mL |
| Ambient temperature | ≤ 30 °C |
| Relative humidity | ≤ 85 % |
| Ambient temperature | 5 °C to 35 ℃ |
| Relative humidity | ≤ 85 % |
| Cubage of buffer vessel | 1000 ml |
| Max. Residual pressure | ≤ 2 mm Hg |
| Beaker quantity | 600 ml |
| Ambient temperature | (-10) °C ~ 40 °C |
| Relative humidity | ≤ 85 % |
| Thermometer Measurement range | (-5) °C ~ 300 °C |
| Ambient temperature | ≤ 35 ℃ |
| Relative humidity | ≤ 85 % |
| Heating power of electric furnace | 250 W × 2 |
| Total power consumption | ≤ 700 W |
| Graduated Flask | 200 ± 0.2 ml |
| Standard Water Value | 51 ± 1 s |
| Temperature Range | 0 ~ 100 °C |
| Temperature Controlling Accuracy | ± 0.2 °C |
| Graduated Flask | 100 ml |
| Standard Water Value | 51 ± 1 s |
| Temperature Range | 0 ~ 100 °C |
| Temperature Controlling Accuracy | ± 0.1 °C |
| Graduated Flask | 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials) |
| Standard Water Value | 51 ± 1 s |
| Temperature Range | 0 ~ 100 °C |
| Ambient Temperature | 10 °C ~ 40 °C |
| Evaporation bath type and size | Aluminum block bath, φ260 × 130 mm |
| Holes for testing | 3 pieces |
| Size of holes for testing cylinder | φ51 × 70 mm |
| Flow rate display | Flow meter |
| Evaporation bath type and size | Aluminum bath φ260 × 130 mm |
| Holes for testing | 5 pieces |
| Size of holes for testing cylinder | φ51 × 70 mm |
| Working temperature | 160 ℃ ~ 165℃ |
| Bath type | Oil bath |
| Bath capacity | 5000 ml ± 50 ml |
| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 11 pieces |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 11 pieces |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | ≤ 30 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 13 pieces |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 11 pieces |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | 0 ~ 40 ºC |
| Relative humidity | 20 ~ 90 %, RH while 40 ℃ |
| Temperature controlling accuracy | ± 0.1 °C |
| Timing range | 0.0 s ~ 9999.9 s |
| Ambient temperature | 15 to 35°C |
| Relative humidity | ≤ 85% |
| Capillary viscometer | 6 capillary Pinkevitch viscometer tubes |
| Stirring motor | 1200 rpm |
| Ambient temperature | (-10)℃ ~ 35 ℃ |
| Relative humidity | ≤ 85 % |
| Sample cup Inner diameter | 31.0 ~ 32.0 mm |
| Sample cup Wall thickness | 1.0 ~ 1.5 mm |
| Temperature controlling accuracy | ± 0.5 ℃ |
| Refrigeration system | New-type refrigeration compressor |
| Cold trough | Two holes in one trough, and same temperature |
| Ambient temperature | ≤ 30 ℃ |
| Refrigeration system | New-type refrigeration compressor |
| Controlling temperature of cold trough | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
| Ambient temperature | ≤ 30 ℃ |
| Relative humidity | ≤ 85 % |
| Refrigeration system | New-type refrigeration compressor |
| Controlling temperature of cold trough | Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C |
| Ambient temperature | ≤ 30 ℃ |
| Relative humidity | ≤ 85 % |
| Temperature controlling accuracy | ± 0.5 °C |
| Refrigeration system | New-type refrigeration compressor |
| Cold trough | One trough with two baths, temperatures in two baths are equal |
| Controlling temperature of cold trough | Room temperature ~ (-70) °C |
| Refrigeration system | New-type refrigeration compressor |
| Cold trough | One trough with two baths, temperatures in two baths are equal |
| Controlling temperature of cold trough | Room temperature ~ (-70) °C |
| Ambient temperature | ≤ 30 ℃ |
| Temperature controlling accuracy | ± 0.5 °C |
| Refrigeration system | New-type refrigeration compressor |
| Cold trough | One trough with two baths, temperatures in two baths are equal |
| Controlling temperature of cold trough | Room temperature ~ (-70) °C |
| Ambient temperature | ≤ 30 ℃ |
| Refrigeration speed | > 40 °C / 10 min |
| Repeatability for solidifying point | ≤ 2 °C |
| Repeatability for pour point | ≤ 3 °C |
| Capacity | 20 L |
| Temperature range | Ambient +5°C to 100°C |
| Precision | ± 0.1℃ |
| Stirring range | 1200 r/min |
| Freezing point range | -54°C to 2°C |
| Cold bath measurement temperature range | -70° to 20°C |
| Temperature controlling accuracy | ±0.5°C |
| Bath liquids stirring | Electric |
| Chamber quantity | 2 chambers |
| Chamber 01 temperature control | Ambient to -51 ℃ |
| Chamber 02 temperature control | Ambient to -65 ℃ |
| Temperature precision | ±1°C |
| Thermometer | 0 ℃ ~ 360 °C |
| Scale Division | 1 °C |
| Ambient Temperature | ≤ 35 °C |
| Relative Humidity | ≤ 85 % |
| Thermometer | 6 ℃ ~ 400 ℃ |
| Scale Division | 2 °C |
| Spout Aperture | 0.6 ~ 0.8 mm |
| Ambient Temperature | -10 ℃ ~ 50 ℃ |
| Ambient Temperature | 10 ℃ ~ 40 ℃ |
| Relative Humidity | ≤ 85 % |
| Temperature Measurement- Full Scale | Ambient temperature to ~ 400 ℃ |
| Temperature Measurement- Repeatability | ≤ 4 ℃ |
| Ambient Temperature | 10 ℃ ~ 40 °C |
| Relative Humidity | ≤ 80 % |
| Temperature Measurement- Full Scale | Ambient temperature to 300 °C |
| Temperature Measurement- Repeatability | ≤ 8 °C |
| Dimension | 390 x 260 x 590 mm |
| Total power consumption | ≤ 1200 W |
| Power supply | AC 220 V ± 10 %, 50 Hz |
| Heating power of water bath | 1000 W |
| Power supply | AC 220 V ± 10 %, 50 Hz |
| Temperature controlling range in water bath | RT ~ 90 ℃ ± 5 ℃ |
| Cooling bath temperature | (-35) ℃ ± 1 ℃ |
| Evaporation temperature | 35 ℃ ± 1 ℃ |
| Power supply | AC 220 V ± 5 % , 50Hz |
| Measurement range | 0 ~ 75 kV |
| Voltage rising rate | 3 kV ± 10 % / s |
| Distance between electrodes | 2.5 mm |
| Light source | 220 V, 100 W |
| Temperature of grinding milk white light bulb | 2750 ± 50 K |
| Light hole( Φ14) | 26 pieces |
| Color comparing tube | Φ32 mm |
| Samples | 2 |
| Oil bath cubage | 30 L |
| Angle between bomb and water surface | 30 ° |
| Speed of rotary assembly | 100 ± 5 RPM |
| Samples | 6 |
| Temperature controlling mode | Automatic digital temperature |
| Temperature controlling range | Room temperature ~ 160 °C |
| Temperature controlling accuracy | ± 0.2 °C |
| Samples | 8 |
| Temperature | 100 ℃ |
| Temperature controlling accuracy | 0.1 ℃ |
| Flow meter | 3 ± 0.3 L / H oxygen |
| Temperature Range | Ambient to 150℃ |
| Temperature Precision | ± 0.1°C |
| Test Unit | 2 units |
| Heating Power | 1800 W |
| Type | Compact; Desktop |
| Design | Integrated |
| Bath | Metal bath (without water usage) |
| Temperature control point of metal bath | 100℃ ± 1℃ |
| Temperature controlling range | 10 ℃ ~ 35 ℃ |
| Temperature resolution | 0.001 ℃ |
| Mean value of heat capacity | 15 kJ / K |
| Ambient temperature | 20 ℃ ± 5 ℃ |
| Temperature measurement range | 10 ~ 35 ℃ |
| Repeatability error | ≤ 0.2 % (Grade C) |
| Endured pressure in oxygen bomb | 20 MPa |
| Operation environment temperature | 15 ~ 28 ℃ |
| Heat capacity | 14000 ~ 15000 J / K |
| Temperature measurement range | 10 ~ 35 ℃ |
| Repeatability error | ≤ 0.2 % (Grade C) |
| Endured pressure in oxygen bomb | 20 MPa |
| Porcelain crucible | 30 ml |
| Inner iron crucible | 75 ml |
| Outer iron crucible | 190 ml |
| Burner | Mig Burner |
| Bath type | Four holes with a furnace |
| Heating type | Electric resistance furnace |
| Temperature controlling range | 0 ~ 520 °C |
| Temperature controlling accuracy | ± 5 °C |
| Coking furnace | Metal furnace |
| Heating mode | Electric heating |
| Test unit | 5 units |
| Temperature range | Ambient to 550°C |
| Viscosity measurement range | 10 ~ 2000000 MPa•s |
| Ambient temperature | 5 °C ~ 35 °C |
| Ambient humidity | Not more than 80 % |
| Spindles | Four spindles of No.1 ~ 4 |
| Sample hole | 4 pieces |
| Sample quantity | 4 to 12 pieces |
| Ambient temperature | Room temperature to 35 °C |
| Temperature controlling range | Room temperature to 100°C |
| Sample hole | 2 pieces |
| Speed of stirring motor | 1400 rpm |
| Ambient temperature | 10 to 35°C |
| Temperature controlling range | Room Temperature to 100°C |
| Sample hole | 4 pieces |
| Speed of stirring motor | 1400 rpm |
| Speed for sample stirring | 1000 ± 50 rpm |
| Ambient temperature | Room temperature to 35°C |
| Sample hole | 4 pieces |
| Ambient temperature | Room temperature to 35°C |
| Temperature controlling range | 0 to 100°C |
| Temperature controlling accuracy | ± 1°C |
| Sample quantity | 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm) |
| Measurement time | 60, 120, 240, 300, and 600 s at random |
| Measurement range | 7 ppm to 5 % |
| Repeatability | < 0.029 (S + 0.6) |
| Air flow rate | Not less than 150 L / h |
| Max. Preset time | 99 min 59 s (100 min) |
| Chamber diameter of oven | Φ22 mm |
| Heating power of oven | 1400 W × 2 |
| Operation temperature of water bath | RT ~ 90 °C |
| Temperature controlling accuracy | ± 0.1 °C |
| Dimensions | 550 × 520 × 102 mm |
| Pressure meter accuracy | ± 0.4 % kPa |
| Test bomb | Two samples or a group of parallel samples |
| Bath temperature | 37.8 °C |
| Temperature controlling accuracy | 0.1 °C |
| Dimensions | 500 × 560 × 680 mm, 950 × 540 × 720 mm |
| Ambient Temperature | 10°C to 35°C |
| Measurement Range | 0 to 100 mg |
| Resolution | 0.1 µg |
| Max. Electrolysis Speed | 40 µg /s |
| Ambient Temperature Range | ≤ 35°C |
| Relative Humidity | ≤ 85% |
| Heating Mantle Cap Power | 1000 W |
| Sample Determination | 1 at a time |
| Ambient Temperature Range | ≤ 35°C |
| Relative Humidity | ≤ 85% |
| Heating Mantle Cap Power | 1000 W × 2 |
| Sample Determination | 2 at a time |
| Ambient Temperature Range | -10 to 35°C |
| Relative Humidity | ≤85% |
| Distillation Flask | 1000 ml |
| Receiver | 5 ml, with 0.05 ml graduation |
| Maximum current | 400 mA |
| Measurement range | 3 µg to 9999.9 µg |
| Resolution | 0.1 µg |
| Precision 1 | ± 2 µg (3µg H2O to 20µg H2O) |
| Experimental temperature range | -50 to 70°C |
| Test sample volume | 50 ml |
| Ambient temperature range | 10 to 40°C |
| Humidity | ≤ 85% |
| Vessel Volume | 4000 ml × 2 |
| Power of Vacuum pump | 160 W |
| Negative power | 3.7 kPa(27.75 mmHg) |
| Power of shaking machine | 30 W |
| Capacity | 2.0 kVA |
| Speed of voltage increase | 2 k V/ s |
| Voltage inspection accuracy | 0.01 |
| Breakdown sensitivity | < 0.1 kV |
| Measurement range | 32 ℃ to 160 ℃ |
| Ambient temperature | 35 °C |
| Temperature resolution | 0.01 ℃ |
| Beaker volume | 1000 mL |
| Temperature range | Room temperature to 1000 ºC |
| Temperature resolution | 0.1 ºC |
| Temperature fluctuation | ±0.1 ºC |
| Heating rate | 1 ~ 80 ºC / min |
| Measurement range | 0 to 600 penetration scale |
| Timing controller | 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec |
| Time accuracy | ± 0.1 seconds |
| Resolution | 0.01 mm |
| Measurement range | 0 to 600 penetration scale |
| Timing controller | 5 sec or 60 sec |
| Time accuracy | ± 0.1 seconds |
| Resolution | 0.01 mm |
| Penetrometer | {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"} |
| Circulatory Water Bath | {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"} |
| Measurement range | 0 to 600 penetration scale |
| Timing range | 0 sec to 60 sec |
| Time accuracy error | ≥ ± 0.1 seconds |
| Resolution | 0.1 penetration |
| Temperature Range | Ambient to 100°C |
| Temperature Precision | ± 0.1°C |
| Air Flow | 94 mL ± 5 mL/min, with flowmeters |
| Timing Unit | 0 to 99 min 59 s, resolution 1 s |
| Potential measuring range | (0 to ±1999.5) Mv |
| Intrinsic error | 0.1 % ±0.5 mV |
| Input impedance | Ri ≥1 × 1012 Ω |
| Burette capacity | 10 mL |
| Measuring range | 0 to 700 taper degree (digital display table 0-70 mm) |
| Timing device | Timing error is less than ±0.1 s |
| Resolution | 0.01 mm |
| Needle insertion accuracy | ±1 cone insertion degree |