Our LKV-A13 is a double layered, desktop structured Kinematic Viscometer which is designed as per ASTM D2171 / D2171M - 10 “Asphalt Kinematic Viscosity Test (Capillary Viscometer Methods”.
Specifications
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | 3 piece at the same time |
Bath temperature | Ambient temperature ~ 180.0 °C |
Measurement range | 100 ~ 150 °C or 150 ~ 200 °C |
Bath cubage | 23 L |
Temperature controlling accuracy | ± 0.1 °C |
Inner capillary viscometer diameters | 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm |
Mercury thermometer scale division | 0.1 °C |
Features
Maximum heating temperature can reach upto135 ℃ (or 180 ℃)
High temperature resistant glass bath
Electric stirring motor
High precision digital temperature controller
Applications
It is used in the fields of petroleum & its products industries, research and development department.
Request Quote
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | The outer barrel temperature is constant |
Temperature resolution | 0.0001°C |
Precision | RSD ≤0.1 % |
Testing time | 8 min |
Power | ≤1.5 kW |
Power supply | 220 V, 50/60 Hz |
Dimension | 540 × 420 × 420 mm |
Weight | 45 kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode |
Temperature resolution | 0.0001°C |
Precision | RSD ≤0.1 % |
Testing time | 8 min |
Power | ≤1.5 kW |
Power supply | 220 V, 50/60 Hz |
Dimension | 630 × 420 × 450 mm |
Weight | 55 kg |
Calorimeter type | Isoperibol |
Oxygen filling | Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
Bomb volume | 250 ml |
Analysis time | < 8 min full test process: |
Bomb washing | Manual |
Bomb pressure (maximum) | 20 MPa |
Bomb identity | Yes |
No. of Tests | 6/hour |
Temperature resolution | 0.0001 K |
Precision (RSD) | ≤ 0.01 % |
Heat Capacity Stability | ≤ 0.25 % within three months |
Gas requirement | 99.5 % oxygen |
Water requirements | Distilled water |
Energy measurement range | 0 to 50000 J |
Bucket filling | Automatic |
Stirring method | Propeller |
Reproducibility | 0.10 % (analysis of 1 g of benzoic acid) |
Temperature Increase | 2°C (average) |
Temperature measurement | PT1000 (temperature probe) |
Working temperatures | ≤ 32°C |
Cooling type | Refrigerating device |
Network | Yes |
Maximum Power | 0.6 kW |
Power Inverter | No |
Power supply | 220 V ±, 15 to 10 %, 50/60 Hz |
Advance Calculations | Yes |
Dimension | Main body: 440 × 550 × 460 mm Water Tank: 390 × 550 × 440 mm |
Weight | 50 kg |
Calorimeter type | Isoperibol |
Oxygen filling | Semi-automatic |
Bomb volume | 282 ml |
Analysis time | 15 to 25 min |
Bomb washing | Manual |
Bomb pressure (maximum) | 20 MPa |
Bomb identity | No |
No. of Tests | 2 to 4/ hour |
Temperature resolution | 0.0001 K |
Precision (RSD) | ≤ 0.15 % |
Heat Capacity Stability | ≤ 0.25 % within three months |
Gas requirement | 99.5 % Oxygen |
Water requirements | Distilled water |
Energy measurement range | 0 to 50000 J |
Bucket filling | Semi-Automatic |
Stirring method | Blade |
Reproducibility | 0.15 % (analysis of 1 g of benzoic acid) |
Temperature Increase | 2°C (average) |
Temperature measurement | PT1000 (temperature probe) |
Working temperatures | ≤ 32°C |
Cooling type | Automatic by water circulation |
Network | Yes |
Maximum Power | 0.5 kW |
Power Inverter | No |
Power supply | 220 V ±, 15 to 10 %, 50/60 Hz |
Advance Calculations | No |
Dimension | Main body: 600 × 417 × 908 mm |
Weight | 106 kg |
Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON |
Measuring Range For Ethanol | E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON |
Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN Cetane index: 20 to 80/CI |
Measuring Accuracy | Aviation gasoline: ≤ ± 1.5/MON Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON |
Precision (Confidence Level 95%) | Reproducibility: ≤ ± 0.5/RON Repeatability: ≤ ± 0.2/RON |
Minimum Scale | 0.1/RON, 0.1/MON, 0.1/CI |
Response Time | 1 min |
Ambient Temperature | 10°C to 35°C |
Humidity | < 85% RH |
Test Result | LCD display, it can store and print |
Power Supply | AC (220 ± 10%) V, (50 ± 1) Hz |
Measurement item | motor gasoline and diesel |
measurement unit of octane is ON | 40 to 120 |
Permissible error of octane | ± 0.5 max |
Fluctuate range of octane | ± 0.2 max |
measurement unit of cetane is CN | 20 to 100 |
Permissible error of cetane | ± 1 max |
Fluctuate range of cetane | ± 0.5 max |
Measurement time | ± ˂ 20 |
Critical value for battery | 2.5 V |
Sensor | 60 ×100 mm |
Temperature | -10˚C to 40˚C |
Humidity | 30 % to 81 % RH |
Barometric pressure | 64 to 106 kPa |
Measurement of octane standard | ASTM D2699-86, ASTM D2700-86 |
Measurement of cetane standard | ASTM D4737-03 |
Operation duration | 15 h |
Display | LED screen, printable result |
Power consumption | 30 ma |
Weight | 5 kg (max) |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Volumetric analysis | |
Automatic acid titration | |
Automatic potential control | |
Measurement range | |
Potential measurement range | |
Burette volume | |
Minimum titration volume | |
Burette precision | |
Precision | |
Ambient temperature | (-10 )°C to 35 °C |
Relative humidity | ≤ 85 % |
Temperature compensation | |
Preset adjustment range of end point | |
Preset controlling range for titration | |
Precision of titration tube | |
Test tube | Φ18 mm x 100 mm |
Acidometer Full scale | 0 ~ 14.00 pH |
Acidometer Accuracy | ± 0.01 pH |
Heating power | 100 W ~ 1000 W |
Total power consumption | Not more than 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimension | 570 x 540 x 260 mm |
Net weight |
Graduated flask | |
Conical flask | |
Separatory funnel | |
Volumetric analysis | |
Automatic acid titration | |
Automatic potential control | |
Measurement range | |
Potential measurement range | |
Burette volume | |
Minimum titration volume | |
Burette precision | |
Precision | |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature compensation | |
Preset adjustment range of end point | |
Preset controlling range for titration | |
Precision of titration tube | Scale division is 0.02 ml |
Test tube | |
Acidometer Full scale | |
Acidometer Accuracy | |
Heating power | |
Total power consumption | ≤ 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimension | 830 x 290 x 370 mm |
Net weight |
Graduated flask | |
Conical flask | |
Separatory funnel | |
Volumetric analysis | |
Automatic acid titration | |
Automatic potential control | |
Measurement range | ≥0.05 mg KOH/g |
Potential measurement range | 0 to 1800.0 mV |
Burette volume | 10 mL |
Minimum titration volume | 0.001 ml |
Burette precision | ±0.1 %FS |
Precision | Fit or above the relative standards |
Ambient temperature | 5℃ to 35℃ |
Relative humidity | Less 80 % |
Temperature compensation | |
Preset adjustment range of end point | |
Preset controlling range for titration | |
Precision of titration tube | |
Test tube | |
Acidometer Full scale | |
Acidometer Accuracy | |
Heating power | |
Total power consumption | |
Power supply | AC (220±11)V , 50±1 Hz |
Dimension | About 350 × 280 ×178 mm |
Net weight | Main unit 14 kg |
Graduated flask | |
Conical flask | |
Separatory funnel | |
Volumetric analysis | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml |
Automatic acid titration | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH |
Automatic potential control | Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV |
Measurement range | |
Potential measurement range | |
Burette volume | |
Minimum titration volume | |
Burette precision | |
Precision | |
Ambient temperature | 0 ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Temperature compensation | Manual compensation; 5 ~ 60 ℃ |
Preset adjustment range of end point | pH 1 to 13 or ± 100 ~ 1300 mV |
Preset controlling range for titration | 1 ~ 3 pH or 100 ~ 300 mV from end point |
Precision of titration tube | |
Test tube | |
Acidometer Full scale | |
Acidometer Accuracy | |
Heating power | |
Total power consumption | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimension | |
Net weight |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Interior Dimension | 360 × 250 × 545 mm |
Exterior Dimension | 370 × 320 × 630 mm |
Power supply | AC 220 V ± 10 %, 50 Hz |
Temperature controlling accuracy | |
Temperature controlling range | |
Power supply for illumination | |
Power of motor |
Measurement range | |
Stirring speed | |
Heating power | |
Interior Dimension | |
Exterior Dimension | |
Power supply | |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Power of motor | 2 kW |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Ignition Mode | |
Temperature range | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
Aperture of ignition device | 0.8 mm |
Standard oil cup-Inner diameter | 50.7 ~ 50.8 mm |
Standard oil cup- Depth | 55.7 ~ 56.0 mm |
Standard oil cup- Depth of Marked line on the oil cup | 33.9 ~ 34.3 mm |
Standard oil cup-Oil sample cubage | About 70 ml |
Stirring speed | 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B |
Stirring blade | 8 × 40 mm |
Sample temperature rising rate | 1 ~ 12 °C per minute |
Measurement Range | |
Flash Point | |
Resolution | |
Repeatability | |
Reproducibility | |
Accuracy | |
Precision | |
Gas Flame | |
Heating power | 0 ~ 600 W |
Dimension | 420 × 350 × 350 mm |
Total Power Consumption | 600 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Net Weight |
Ambient temperature | 10 °C ~ 40 °C |
Relative humidity | ≤ 80 % |
Ignition Mode | |
Temperature range | |
Aperture of ignition device | |
Standard oil cup-Inner diameter | |
Standard oil cup- Depth | |
Standard oil cup- Depth of Marked line on the oil cup | |
Standard oil cup-Oil sample cubage | |
Stirring speed | |
Stirring blade | |
Sample temperature rising rate | |
Measurement Range | Ambient Temperature ~ 250 °C |
Flash Point | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C |
Resolution | 0.1 °C |
Repeatability | |
Reproducibility | |
Accuracy | |
Precision | 0.005 |
Gas Flame | 3 ~ 4 mm |
Heating power | |
Dimension | 550 × 470 × 500 mm |
Total Power Consumption | 350 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Net Weight |
Ambient temperature | 10 °C ~ 40 ℃ |
Relative humidity | ≤ 80 % |
Ignition Mode | electron igniter / gas flame |
Temperature range | Room Temperature ~ 300 ℃ |
Aperture of ignition device | |
Standard oil cup-Inner diameter | |
Standard oil cup- Depth | |
Standard oil cup- Depth of Marked line on the oil cup | |
Standard oil cup-Oil sample cubage | |
Stirring speed | |
Stirring blade | |
Sample temperature rising rate | |
Measurement Range | Room Temperature ~ 300 ℃ |
Flash Point | |
Resolution | 0.1 ℃ |
Repeatability | ≤ 2 ℃ |
Reproducibility | ≤ 4 ℃ |
Accuracy | 0.005 |
Precision | |
Gas Flame | |
Heating power | |
Dimension | |
Total Power Consumption | 300 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Net Weight |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Timing range | 1 s to 9 min 59 s |
Temperature controlling range | Room temperature to 99.9 °C |
Temperature controlling accuracy | ± 1 °C |
Temperature resolution | 0.1 °C |
Stirring speed | 1500 ± 15 rpm |
Heating power for temperature controlling | 600 W |
Total power consumption | ≤ 800 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimension | 520 × 460 × 122 mm |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Timing range | |
Temperature controlling range | Room temperature to 99.9 °C |
Temperature controlling accuracy | ± 1 °C |
Temperature resolution | |
Stirring speed | 1500 ± 15 rpm |
Heating power for temperature controlling | |
Total power consumption | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimension | 740 × 510 × 680 mm |
Heating power | 2 kW |
Cooling power | 0.5 kW |
Steam temperature | 0 to 400℃ |
Oven temperature | 0 to 500℃ |
Refrigeration temperature | 0 to 60℃ |
Refrigeration accuracy | ± 1℃ |
Temperature measurement accuracy | ± 0.1℃ |
Volume accuracy | ± 0.1 ml |
Power | AC 220 V ± 10% 50 Hz |
Ambient temperature | -10°C to 35°C |
Relative humidity | ≤ 85 % |
Thermometer | Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C |
Scale division | 0.1 ℃ |
Total length | 8000 mm |
Water cooling tube | 4500 mm |
Heating power system | 1000 W |
Total power consumption | ≤ 1100 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Graduated flasks | 100 ml |
Scale division of graduated flask | 1ml |
Distillation flask | 125 ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling accuracy | ± 0.5 °C |
Temperature range air bath | Room temperature+ 10 °C to 60 °C |
Thermometer | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ |
Inner diameter of electric furnace | φ32 mm, φ38 mm |
Outer diameter of electric furnace | φ50 mm |
Dimension | 830 x 610 x 870 mm |
Heating power system | 1000 W × 2 |
Total power consumption | ≤ 2500 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Graduated flasks | 100 ml |
Distillation flask | 125 ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling accuracy | ± 0.5 °C |
Thermometer | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ |
Division value | 1°C |
Scale division | 1 ml |
Inner diameter of electric furnace | φ32 mm, φ38 mm |
Outer diameter of electric furnace | φ50 mm |
Dimension | 830 x 610 x 870 mm |
Heating power system | 1000 W × 2 |
Total power consumption | ≤ 5000 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Beaker quantity | 600 ml |
Ambient temperature | (-10) °C ~ 40 °C |
Relative humidity | ≤ 85 % |
Thermometer Measurement range | (-5) °C ~ 300 °C |
Thermometer Scale division | 1 °C |
Thermometer Immersion depth | 7 mm |
Thermometer Total length | 390 mm |
Grease cup Material | Chromium-plated brass |
Grease cup Inner diameter | Φ9.92 mm |
Grease cup Orifice | Φ2.8 mm |
Grease cup Height | 12 mm |
Test tube Material | Heat-resistant borosilicate glass |
Test tube Inner diameter | 11.1 mm to 12.7 mm |
Heater | 800 W |
Stirring motor | 60 rpm |
Dimensions | 510 x 280 x 570 mm |
Heating power of electric furnace | |
Total power consumption | ≤ 900 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Beaker quantity | |
Ambient temperature | ≤ 35 ℃ |
Relative humidity | ≤ 85 % |
Thermometer Measurement range | |
Thermometer Scale division | |
Thermometer Immersion depth | |
Thermometer Total length | |
Grease cup Material | |
Grease cup Inner diameter | |
Grease cup Orifice | |
Grease cup Height | |
Test tube Material | |
Test tube Inner diameter | |
Heater | |
Stirring motor | |
Dimensions | |
Heating power of electric furnace | 250 W × 2 |
Total power consumption | ≤ 700 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Graduated Flask | 200 ± 0.2 ml |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Ambient Temperature | |
Temperature Controlling Accuracy | ± 0.2 °C |
Relative Humidity | |
Timer | |
Accuracy Of Timer | 0.01 s |
Heating Power | |
Dimension | 510 x 360 x 270 mm |
Power Of Heater | 550 W / 220 V |
Total Power Consumption | |
Power Supply | |
=#REF! |
Graduated Flask | 100 ml |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Ambient Temperature | |
Temperature Controlling Accuracy | ± 0.1 °C |
Relative Humidity | |
Timer | |
Accuracy Of Timer | 0.01 s |
Heating Power | |
Dimension | 510 x 365 x 290 mm |
Power Of Heater | 550 W / 220 V |
Total Power Consumption | |
Power Supply | |
=#REF! |
Graduated Flask | 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials) |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Ambient Temperature | 10 °C ~ 40 °C |
Temperature Controlling Accuracy | ± 0.1 °C |
Relative Humidity | ≤ 85 % |
Timer | Max is 9999 s |
Accuracy Of Timer | |
Heating Power | 700 W |
Dimension | 630 x 490 x 760 mm |
Power Of Heater | |
Total Power Consumption | ≤ 800 W |
Power Supply | AC 220 V ± 10 %, 50 Hz |
=#REF! |
Bath type | |
Bath capacity | |
Ambient temperature | |
Relative humidity | |
Temperature controlling range | |
Temperature controlling accuracy | |
Heating type | |
Evaporation bath type and size | Aluminum block bath, φ260 × 130 mm |
Constant temperature bath | |
Holes for testing | 3 pieces |
Size of holes for testing cylinder | φ51 × 70 mm |
Flow rate display | Flow meter |
Working temperature | 60 ℃ to 165 ℃ |
Temperature controlling methods | Automatic temperature controlling |
Temperature display | Digitally displayed |
Working pressure for decompression valve | 0.035 MPa |
Gas source | Compressed air > 110 L/min |
Air flow rate at jet nozzle | |
Dimension | 550 x 370 x 335 mm |
Total power consumption | |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz; 2.5 kW |
Bath type | |
Bath capacity | |
Ambient temperature | |
Relative humidity | |
Temperature controlling range | |
Temperature controlling accuracy | |
Heating type | |
Evaporation bath type and size | Aluminum bath φ260 × 130 mm |
Constant temperature bath | |
Holes for testing | 5 pieces |
Size of holes for testing cylinder | φ51 × 70 mm |
Flow rate display | |
Working temperature | 160 ℃ ~ 165℃ |
Temperature controlling methods | |
Temperature display | |
Working pressure for decompression valve | 0.07 MPa |
Gas source | |
Air flow rate at jet nozzle | 600 ml / s |
Dimension | 590 x 480 × 340 mm |
Total power consumption | |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz; 3.5 kW |
Bath type | Oil bath |
Bath capacity | 5000 ml ± 50 ml |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling range | RT to 250 °C |
Temperature controlling accuracy | 150 °C ± 3 °C;180 °C ± 3 °C;250 °C ± 5 °C |
Heating type | Electric heater |
Evaporation bath type and size | |
Constant temperature bath | |
Holes for testing | |
Size of holes for testing cylinder | |
Flow rate display | |
Working temperature | |
Temperature controlling methods | |
Temperature display | |
Working pressure for decompression valve | |
Gas source | |
Air flow rate at jet nozzle | |
Dimension | 840 x 380 x 600 mm |
Total power consumption | ≤ 1200 W |
Heating power | 1000 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | |
Bath temperature | |
Measurement range | |
Bath cubage | |
Temperature controlling range | |
Temperature controlling accuracy | ± 0.1 °C |
Illumination | |
Constant temperature bath | 20 L; two layers water bath |
Timing range | |
Barometric | |
Timing accuracy | |
Timing device | |
Temperature sensor | Industrial platinum resistance; Pt100 |
Inner capillary viscometer diameters | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively (inner diameters of 5.0 and 6.0mm are optional) |
Mercury thermometer scale division |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | |
Bath temperature | |
Measurement range | |
Bath cubage | |
Temperature controlling range | Ambient temperature ~ 100 °C |
Temperature controlling accuracy | ± 0.1 °C |
Illumination | |
Constant temperature bath | 20 L, two layer bath |
Timing range | |
Barometric | |
Timing accuracy | |
Timing device | 0.1 s ~ 999.9 s, resolution is 0.1 s |
Temperature sensor | |
Inner capillary viscometer diameters | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively |
Mercury thermometer scale division |
Ambient temperature | ≤ 30 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 13 pieces |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | |
Bath temperature | |
Measurement range | |
Bath cubage | |
Temperature controlling range | Ambient temperature ~ 70 °C |
Temperature controlling accuracy | ± 0.1 °C |
Illumination | 6 W / 220 V fluorescent lamp |
Constant temperature bath | 5.8 L with stainless steel inner tank |
Timing range | |
Barometric | |
Timing accuracy | |
Timing device | |
Temperature sensor | |
Inner capillary viscometer diameters | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0 mm |
Mercury thermometer scale division |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | 4 piece at the same time |
Bath temperature | |
Measurement range | Ambient Temperature ~ 100.0 °C |
Bath cubage | 20 L |
Temperature controlling range | |
Temperature controlling accuracy | ± 0.1 °C |
Illumination | |
Constant temperature bath | |
Timing range | 0.0 s ~ 9999.9 s |
Barometric | |
Timing accuracy | ≤ ± 0.05 % in 60 min |
Timing device | |
Temperature sensor | |
Inner capillary viscometer diameters | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 mm |
Mercury thermometer scale division |
Measurement range | |
Temperature controlling accuracy | |
Refrigeration system | |
Bath stirrer | |
Sample stirrer | |
Cold trough | |
Controlling temperature of cold trough | |
Constant temperature bath Cubage | |
Constant temperature bath Types | |
Temperature Range | |
Temperature sensor | |
Stirring motor Power | |
Stirring motor Speed | |
Ambient temperature | (-10)℃ ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration speed | |
Repeatability for solidifying point | |
Repeatability for pour point | |
Reproducibility | |
Pressure of cooling water | |
The lowest temperature | |
Sample cup Inner diameter | 31.0 ~ 32.0 mm |
Sample cup Wall thickness | 1.0 ~ 1.5 mm |
Sample cup Height | 115 ~ 125 mm |
Pumping pressure | U type differential pressure meter 1961 Pa (200 mm H2O) |
Dimensions | |
Inner Dimensions | |
Outer Dimensions | |
Total power consumption | ≤ 150 W |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Measurement range | |
Temperature controlling accuracy | ± 0.5 ℃ |
Refrigeration system | New-type refrigeration compressor |
Bath stirrer | |
Sample stirrer | |
Cold trough | Two holes in one trough, and same temperature |
Controlling temperature of cold trough | |
Constant temperature bath Cubage | |
Constant temperature bath Types | |
Temperature Range | |
Temperature sensor | |
Stirring motor Power | |
Stirring motor Speed | |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration speed | |
Repeatability for solidifying point | |
Repeatability for pour point | |
Reproducibility | |
Pressure of cooling water | |
The lowest temperature | |
Sample cup Inner diameter | |
Sample cup Wall thickness | |
Sample cup Height | |
Pumping pressure | |
Dimensions | 620 x 460 x 355 mm |
Inner Dimensions | |
Outer Dimensions | |
Total power consumption | 1000 W |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Measurement range | |
Temperature controlling accuracy | |
Refrigeration system | New-type refrigeration compressor |
Bath stirrer | |
Sample stirrer | |
Cold trough | |
Controlling temperature of cold trough | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
Constant temperature bath Cubage | |
Constant temperature bath Types | |
Temperature Range | |
Temperature sensor | |
Stirring motor Power | |
Stirring motor Speed | |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration speed | |
Repeatability for solidifying point | |
Repeatability for pour point | |
Reproducibility | |
Pressure of cooling water | |
The lowest temperature | |
Sample cup Inner diameter | |
Sample cup Wall thickness | |
Sample cup Height | |
Pumping pressure | |
Dimensions | |
Inner Dimensions | 560 x 380 x 250 mm |
Outer Dimensions | 920 x 670 x 510 mm |
Total power consumption | ≤ 1500 W |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Measurement range | |
Temperature controlling accuracy | |
Refrigeration system | New-type refrigeration compressor |
Bath stirrer | |
Sample stirrer | |
Cold trough | |
Controlling temperature of cold trough | Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C |
Constant temperature bath Cubage | |
Constant temperature bath Types | |
Temperature Range | |
Temperature sensor | |
Stirring motor Power | |
Stirring motor Speed | |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration speed | |
Repeatability for solidifying point | |
Repeatability for pour point | |
Reproducibility | |
Pressure of cooling water | |
The lowest temperature | |
Sample cup Inner diameter | |
Sample cup Wall thickness | |
Sample cup Height | |
Pumping pressure | |
Dimensions | 930 x 570 x 108 mm |
Inner Dimensions | |
Outer Dimensions | |
Total power consumption | ≤ 1700 W |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz; |
Thermometer | 0 ℃ ~ 360 °C |
Scale Division | 1 °C |
Spout Aperture | |
Ambient Temperature | ≤ 35 °C |
Relative Humidity | ≤ 85 % |
Temperature Measurement- Full Scale | |
Temperature Measurement- Repeatability | |
Temperature Measurement- Reproducibility | |
Temperature Measurement- Resolution | |
Test accuracy | |
Reappearance | |
Graduation | |
Outer Crucible-Material | Carbon structural steel |
Outer Crucible-Diameter Of Upper Opening | Φ100 ± 5 mm |
Outer Crucible-Height | 50 ± 5 mm |
Outer Crucible-Diameter Of Bottom | Φ56 ± 2 mm |
Inner Crucible-Material | Carbon structural steel |
Inner Crucible-Diameter Of Upper Opening | Φ64 ± 1 mm |
Inner Crucible-Height | 47 ± 1 mm |
Inner Crucible-Diameter Of Bottom | Φ38± 1 mm |
Inner Crucible-Scale Line | 12mm away from the rim of upper opening and 18mm away from the rim of upper opening |
Precision | |
Gas Tube | Φ0.8 ~ Φ1 mm |
Flame | 3 to 4 mm |
Heater | Heated by an electric furnace |
Heating Power | 1000W |
Dimensions | 410 x 360 x 240 mm |
Power Consumption | ≤ 1100 W |
Power Supply | AC 220 V ± 10 %, 50Hz |
=#REF! |
Thermometer | 6 ℃ ~ 400 ℃ |
Scale Division | 2 °C |
Spout Aperture | 0.6 ~ 0.8 mm |
Ambient Temperature | -10 ℃ ~ 50 ℃ |
Relative Humidity | ≤ 85 % |
Temperature Measurement- Full Scale | |
Temperature Measurement- Repeatability | |
Temperature Measurement- Reproducibility | |
Temperature Measurement- Resolution | |
Test accuracy | |
Reappearance | |
Graduation | |
Outer Crucible-Material | |
Outer Crucible-Diameter Of Upper Opening | |
Outer Crucible-Height | |
Outer Crucible-Diameter Of Bottom | |
Inner Crucible-Material | |
Inner Crucible-Diameter Of Upper Opening | |
Inner Crucible-Height | |
Inner Crucible-Diameter Of Bottom | |
Inner Crucible-Scale Line | |
Precision | |
Gas Tube | |
Flame | |
Heater | |
Heating Power | |
Dimensions | 480 x 400 x 300 mm |
Power Consumption | 0 ~ 600 W |
Power Supply | AC 220 V ± 10 %, 50 Hz |
=#REF! |
Thermometer | |
Scale Division | |
Spout Aperture | |
Ambient Temperature | 10 ℃ ~ 40 ℃ |
Relative Humidity | ≤ 85 % |
Temperature Measurement- Full Scale | Ambient temperature to ~ 400 ℃ |
Temperature Measurement- Repeatability | ≤ 4 ℃ |
Temperature Measurement- Reproducibility | |
Temperature Measurement- Resolution | |
Test accuracy | 0.005 |
Reappearance | ≤ 8 times |
Graduation | 0.1 ℃ |
Outer Crucible-Material | |
Outer Crucible-Diameter Of Upper Opening | |
Outer Crucible-Height | |
Outer Crucible-Diameter Of Bottom | |
Inner Crucible-Material | |
Inner Crucible-Diameter Of Upper Opening | |
Inner Crucible-Height | |
Inner Crucible-Diameter Of Bottom | |
Inner Crucible-Scale Line | |
Precision | |
Gas Tube | |
Flame | |
Heater | |
Heating Power | |
Dimensions | 620 x 500 x 440 mm |
Power Consumption | 400 W |
Power Supply | AC 220 V ± 10 %, 50 Hz |
=#REF! |
Thermometer | |
Scale Division | |
Spout Aperture | |
Ambient Temperature | 10 ℃ ~ 40 °C |
Relative Humidity | ≤ 80 % |
Temperature Measurement- Full Scale | Ambient temperature to 300 °C |
Temperature Measurement- Repeatability | ≤ 8 °C |
Temperature Measurement- Reproducibility | ≤ 16 °C |
Temperature Measurement- Resolution | 0.1 °C |
Test accuracy | 0.002 |
Reappearance | |
Graduation | |
Outer Crucible-Material | |
Outer Crucible-Diameter Of Upper Opening | |
Outer Crucible-Height | |
Outer Crucible-Diameter Of Bottom | |
Inner Crucible-Material | |
Inner Crucible-Diameter Of Upper Opening | |
Inner Crucible-Height | |
Inner Crucible-Diameter Of Bottom | |
Inner Crucible-Scale Line | |
Precision | 0.005 |
Gas Tube | |
Flame | 3 to 4 mm |
Heater | |
Heating Power | |
Dimensions | 550 x 470 x 410 mm |
Power Consumption | ≤ 500 W |
Power Supply | AC 220 V ± 10 %, 50 Hz |
=#REF! |
Light source | |
Temperature of grinding milk white light bulb | |
Light hole( Φ14) | |
Color comparing tube | |
Dimension | 390 x 260 x 590 mm |
Non-colorful flat bottom glass tube | |
Observation lens | |
Total power consumption | ≤ 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Heating power of water bath | 1000 W |
Relative humidity | ≤ 85 % |
Ambient temperature | ≤ 35 °C |
Temperature display mode of water bath | Digitally displayed by a LED |
Temperature controlling range in water bath | RT to 90 °C |
Temperature controlling accuracy in water bath: | ± 1 °C |
Temperature controlling range in funnel | RT to 90 °C |
Temperature display mode of funnel | Digitally displayed by a LED |
Temperature controlling accuracy in funnel | ± 2 °C |
Controlling case (L × W × H) | 390 × 260 × 590 mm |
Water bath (L × W × H) | 90 × 290 × 370 mm |
Cooling bath temperature | |
Evaporation temperature | |
Flow rate | |
Timing range of timer | |
Measurement range | |
Voltage rising rate | |
Distance between electrodes | |
Output power |
Light source | |
Temperature of grinding milk white light bulb | |
Light hole( Φ14) | |
Color comparing tube | |
Dimension | |
Non-colorful flat bottom glass tube | |
Observation lens | |
Total power consumption | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Heating power of water bath | |
Relative humidity | |
Ambient temperature | |
Temperature display mode of water bath | |
Temperature controlling range in water bath | RT ~ 90 ℃ ± 5 ℃ |
Temperature controlling accuracy in water bath: | |
Temperature controlling range in funnel | |
Temperature display mode of funnel | |
Temperature controlling accuracy in funnel | |
Controlling case (L × W × H) | |
Water bath (L × W × H) | |
Cooling bath temperature | (-35) ℃ ± 1 ℃ |
Evaporation temperature | 35 ℃ ± 1 ℃ |
Flow rate | 2 ~ 3 L / min |
Timing range of timer | 0 ~ 60 min |
Measurement range | |
Voltage rising rate | |
Distance between electrodes | |
Output power |
Light source | |
Temperature of grinding milk white light bulb | |
Light hole( Φ14) | |
Color comparing tube | |
Dimension | |
Non-colorful flat bottom glass tube | |
Observation lens | |
Total power consumption | |
Power supply | AC 220 V ± 5 % , 50Hz |
Heating power of water bath | |
Relative humidity | |
Ambient temperature | |
Temperature display mode of water bath | |
Temperature controlling range in water bath | |
Temperature controlling accuracy in water bath: | |
Temperature controlling range in funnel | |
Temperature display mode of funnel | |
Temperature controlling accuracy in funnel | |
Controlling case (L × W × H) | |
Water bath (L × W × H) | |
Cooling bath temperature | |
Evaporation temperature | |
Flow rate | |
Timing range of timer | |
Measurement range | 0 ~ 75 kV |
Voltage rising rate | 3 kV ± 10 % / s |
Distance between electrodes | 2.5 mm |
Output power | 2 kVA |
Light source | 220 V, 100 W |
Temperature of grinding milk white light bulb | 2750 ± 50 K |
Light hole( Φ14) | 26 pieces |
Color comparing tube | Φ32 mm |
Dimension | 440 x 420 x 340 mm |
Non-colorful flat bottom glass tube | 120 ~ 130 mm |
Observation lens | Concave mirror and separated bar |
Total power consumption | |
Power supply | |
Heating power of water bath | |
Relative humidity | |
Ambient temperature | |
Temperature display mode of water bath | |
Temperature controlling range in water bath | |
Temperature controlling accuracy in water bath: | |
Temperature controlling range in funnel | |
Temperature display mode of funnel | |
Temperature controlling accuracy in funnel | |
Controlling case (L × W × H) | |
Water bath (L × W × H) | |
Cooling bath temperature | |
Evaporation temperature | |
Flow rate | |
Timing range of timer | |
Measurement range | |
Voltage rising rate | |
Distance between electrodes | |
Output power |
Samples | 2 |
Temperature | |
Oil bath cubage | 30 L |
Angle between bomb and water surface | 30 ° |
Speed of rotary assembly | 100 ± 5 RPM |
Pressure sensor | 0 to 1.6 Mpa; Accuracy: ±2% |
Oil bath Temperature controlling range | RT to 200 °C (adjustable) |
Temperature controlling mode | |
Temperature controlling range | |
Temperature controlling accuracy | ± 0.1 °C |
Flow meter | |
Size | 550 × 800 × 1000 mm |
Power of heater | 2500 W |
Power supply | 220 V ± 10 % |
Power consumption | |
Weight | 45 kg |
Dimension | 860 × 710 × 104 mm |
Samples | 6 |
Temperature | |
Oil bath cubage | |
Angle between bomb and water surface | |
Speed of rotary assembly | |
Pressure sensor | |
Oil bath Temperature controlling range | |
Temperature controlling mode | Automatic digital temperature |
Temperature controlling range | Room temperature ~ 160 °C |
Temperature controlling accuracy | ± 0.2 °C |
Flow meter | |
Size | |
Power of heater | |
Power supply | 220 V, 50 Hz |
Power consumption | ≤ 1100 W |
Weight | |
Dimension |
Samples | 8 |
Temperature | 100 ℃ |
Oil bath cubage | |
Angle between bomb and water surface | |
Speed of rotary assembly | |
Pressure sensor | |
Oil bath Temperature controlling range | |
Temperature controlling mode | |
Temperature controlling range | |
Temperature controlling accuracy | 0.1 ℃ |
Flow meter | 3 ± 0.3 L / H oxygen |
Size | |
Power of heater | |
Power supply | 220 V ± 10 %, 60 Hz |
Power consumption | |
Weight | |
Dimension |
Temperature Range | Ambient to 150℃ |
Temperature Precision | ± 0.1°C |
Test Unit | 2 units |
Heating Power | 1800 W |
Ambient Temperature | (Room temperature to 35°C |
Relative Humidity | ≤ 85 % |
Power Supply | AC (220 ± 10 %) V, 50 Hz |
Heat capacity | |
Temperature measurement range | |
Temperature controlling range | 10 ℃ ~ 35 ℃ |
Repeatability error | |
Endured pressure in oxygen bomb | |
Operation environment temperature | |
Temperature resolution | 0.001 ℃ |
Mean value of heat capacity | 15 kJ / K |
Heating power | |
Temperature fluctuation | |
Ambient temperature | 20 ℃ ± 5 ℃ |
Relative humidity | ≤ 85 % |
Endured pressure of oxygen bomb | 20 MPa Test pressure in oxygen bomb: 3 MPa |
Temperature saved | 31 pieces |
Measurement accuracy for heat value | ≤ 0.2 % |
Dimension | 400 × 400 × 600 mm |
weight | 18 kg |
Power supply |
Heat capacity | |
Temperature measurement range | 10 ~ 35 ℃ |
Temperature controlling range | |
Repeatability error | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb | 20 MPa |
Operation environment temperature | 15 ~ 28 ℃ |
Temperature resolution | 0.001 ℃ |
Mean value of heat capacity | |
Heating power | |
Temperature fluctuation | Not more than 1 ℃ during a test |
Ambient temperature | Less than 85 % |
Relative humidity | |
Endured pressure of oxygen bomb | |
Temperature saved | |
Measurement accuracy for heat value | |
Dimension | |
weight | |
Power supply | AC 220 V ± 5 %, 50 Hz |
Heat capacity | 14000 ~ 15000 J / K |
Temperature measurement range | 10 ~ 35 ℃ |
Temperature controlling range | |
Repeatability error | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb | 20 MPa |
Operation environment temperature | 15 ~ 28 ℃ |
Temperature resolution | 0.001 ℃ |
Mean value of heat capacity | |
Heating power | |
Temperature fluctuation | Not more than 1 ℃ during a test |
Ambient temperature | Less than 85 % |
Relative humidity | |
Endured pressure of oxygen bomb | |
Temperature saved | |
Measurement accuracy for heat value | |
Dimension | |
weight | |
Power supply | AC 220 V ± 5 %, 50 Hz |
Porcelain crucible | 30 ml |
Inner iron crucible | 75 ml |
Outer iron crucible | 190 ml |
Burner | Mig Burner |
Bath type | |
Heating type | |
Temperature controlling range | |
Temperature controlling accuracy | |
Relative humidity | |
Dimensions | 400 x 380 x 270 mm |
Total power consumption | |
Ambient temperature | |
Heating power | |
Power supply |
Porcelain crucible | |
Inner iron crucible | |
Outer iron crucible | |
Burner | |
Bath type | Four holes with a furnace |
Heating type | Electric resistance furnace |
Temperature controlling range | 0 ~ 520 °C |
Temperature controlling accuracy | ± 5 °C |
Relative humidity | ≤ 85 % |
Dimensions | 730 x 510 x 470 mm |
Total power consumption | ≤ 2000 W |
Ambient temperature | ~ 35 °C |
Heating power | 300 W +600 W +1000 W |
Power supply | 220 V ± 10 %, 50 Hz |
Coking furnace | Metal furnace |
Heating mode | Electric heating |
Test unit | 5 units |
Temperature range | Ambient to 550°C |
Temperature precision | ≤ ± 5℃ |
Ambient temperature | (Room temp. to 35)℃ |
Relative humidity | ≤ 85 % |
Power consumption | 2000 W |
Power Supply | AC 220V ±10%, 50Hz |
Sample hole | 4 pieces |
Sample quantity | 4 to 12 pieces |
Ambient temperature | Room temperature to 35 °C |
Temperature controlling range | Room temperature to 100°C |
Temperature controlling accuracy | ± 1°C |
Temperature controller | Pt100 |
Relative humidity | ≤ 85 % |
Timing range | 1 min to 24 hours |
Heating power | 600 W for temperature controlling; 1000 W for auxiliary heating |
Total power consumption | ≤ 1800 W |
Dimensions | 580 × 460 × 760 mm |
Power supply | AC 220 V ± 10 %, 50 Hz |
Sample hole | 2 pieces |
Speed of stirring motor | 1400 rpm |
Ambient temperature | 10 to 35°C |
Temperature controlling range | Room Temperature to 100°C |
Temperature controlling accuracy | ± 0.5°C |
Temperature controller | Pt100 |
Relative humidity | ≤ 85 % |
Delay time | 0.01 s to 99 hours 99 minutes |
Heating power | 600 W for temperature controlling; 1000 W for auxiliary heating |
Total power consumption | ≤ 1700 W |
Dimensions | 580 × 520 × 810 mm |
Power supply | AC 220 V ± 10 %, 50 Hz |
Sample hole | 4 pieces |
Speed of stirring motor | 1400 rpm |
Speed for sample stirring | 1000 ± 50 rpm |
Ambient temperature | Room temperature to 35°C |
Temperature controlling range | 0 to 100°C |
Temperature controlling accuracy | ± 1°C |
Temperature controller | Pt100 |
Relative humidity | ≤ 85 % |
Timing range | 1 min to 24 hours |
Heating power | 600 W for temperature controlling; 1000 W for auxiliary heating |
Total power consumption | ≤ 1800 W |
Dimensions | 880 × 430 × 840 mm |
Power supply | AC 220 V ± 10%, 50Hz |
Sample hole | 4 pieces |
Ambient temperature | Room temperature to 35°C |
Temperature controlling range | 0 to 100°C |
Temperature controlling accuracy | ± 1°C |
Relative humidity | ≤ 85 % |
Timing range | 1 min to 24 hours |
Total power consumption | ≤ 1800W |
Dimensions | 880 × 430 × 960 mm, 590 × 490 × 430 mm |
Power supply | AC 220 V ± 10 %, 50 Hz |
Air flow rate | |
Max. Preset time | |
Chamber diameter of oven | |
Heating power of oven | |
Max. Temperature of oven | |
Sample quantity | 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm) |
Measurement time | 60, 120, 240, 300, and 600 s at random |
Measurement range | 7 ppm to 5 % |
Repeatability | < 0.029 (S + 0.6) |
Reproducibility | < 0.063 (S + 0.6) |
Temperature | 5 ℃ to 40 ℃ |
Relative humidity | ≤ 85 % (30 ℃) |
Power supply | AC 220 V ± 20 V, 50 Hz |
Rated power | 30 W |
Dimensions | 468 x 368 x 136 mm |
Weight | 13 kg |
Air flow rate | Not less than 150 L / h |
Max. Preset time | 99 min 59 s (100 min) |
Chamber diameter of oven | Φ22 mm |
Heating power of oven | 1400 W × 2 |
Max. Temperature of oven | 950 °C |
Sample quantity | |
Measurement time | |
Measurement range | |
Repeatability | |
Reproducibility | |
Temperature | |
Relative humidity | |
Power supply | AC 220 V ± 10 %, 50 Hz |
Rated power | |
Dimensions | 720 x 620 x 630 mm, 560 x 410 x 670 mm, 820 x 500 x 290 mm |
Weight |
Test bomb | |
Operation temperature of water bath | RT ~ 90 °C |
Bath temperature | |
Temperature controlling accuracy | ± 0.1 °C |
Dimensions | 550 × 520 × 102 mm |
Pressure meter accuracy | ± 0.4 % kPa |
Heating power of water bath | 1600 W |
Total power consumption | ≤ 1700 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Relative humidity | ≤ 85 % |
Ambient temperature | (-10) °C ~ 35 °C |
Pressure range |
Test bomb | Two samples or a group of parallel samples |
Operation temperature of water bath | |
Bath temperature | 37.8 °C |
Temperature controlling accuracy | 0.1 °C |
Dimensions | 500 × 560 × 680 mm, 950 × 540 × 720 mm |
Pressure meter accuracy | |
Heating power of water bath | 1400 W |
Total power consumption | ≤ 1500 W |
Power supply | AC 220 V ± 10 % |
Relative humidity | ≤ 85 % |
Ambient temperature | (-10) °C ~ 35 °C |
Pressure range | 0 ~ 200 kPa |
Ambient Temperature | 10°C to 35°C |
Measurement Range | 0 to 100 mg |
Resolution | 0.1 µg |
Max. Electrolysis Speed | 40 µg /s |
Amount and Precision of electrolysed water | 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 % |
Relative Humidity | ≤ 85 % |
Max. Power Consumption | 30 W |
Power Supply | AC 220 V ± 20 %, 50 Hz |
Dimension | 320 × 240 × 150 mm |
Net Weight | 5 kg |
Ambient Temperature Range | ≤ 35°C |
Relative Humidity | ≤ 85% |
Distillation Flask | |
Receiver | |
Condenser | |
Heating Unit | |
Heating Mantle Cap Power | 1000 W |
Sample Determination | 1 at a time |
Dimension (exclusive of test vessels) | |
Dimension (Inclusive of test vessels) | |
Dimension | 580 × 350 × 300 mm |
Power Supply | AC 200 ± 10 % V, 50 Hz |
Ambient Temperature Range | ≤ 35°C |
Relative Humidity | ≤ 85% |
Distillation Flask | |
Receiver | |
Condenser | |
Heating Unit | |
Heating Mantle Cap Power | 1000 W × 2 |
Sample Determination | 2 at a time |
Dimension (exclusive of test vessels) | |
Dimension (Inclusive of test vessels) | |
Dimension | 690 × 570 × 310 mm |
Power Supply | AC 200 ± 10 % V, 50 Hz |
Ambient Temperature Range | -10 to 35°C |
Relative Humidity | ≤85% |
Distillation Flask | 1000 ml |
Receiver | 5 ml, with 0.05 ml graduation |
Condenser | 400 mm with ± 5 mm accuracy |
Heating Unit | Heating mantle cap, |
Heating Mantle Cap Power | 500 W × 2, continuous adjustment |
Sample Determination | 2 at a time |
Dimension (exclusive of test vessels) | 425 × 330 × 150 mm |
Dimension (Inclusive of test vessels) | 425 × 330 × 1180 mm |
Dimension | |
Power Supply | AC 200 ± 10 % V, 50 Hz |
Measurement range | 0 to 600 penetration scale |
Timing controller | 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec |
Time accuracy | ± 0.1 seconds |
Resolution | 0.01 mm |
Penetration accuracy | ± 1 penetration |
Temperature control accuracy | 25 °C ± 0.1 °C |
Temperature control mode | High accuracy digital temperature controller |
Weight of standard needle | 2.5 ± 0.05 g |
Weight of standard cone | 102.5 ± 0.05 g |
Power consumption | 200 W |
Dimensions (L × W × H) | 750 × 450 × 750 mm |
Weight | 40 kg |
Measurement range | 0 to 600 penetration scale |
Timing controller | 5 sec or 60 sec |
Time accuracy | ± 0.1 seconds |
Resolution | 0.01 mm |
Penetration accuracy | ± 1 penetration |
Temperature control accuracy | 25 °C ± 0.1 °C |
Environment temperature | 15 °C to 35 °C |
Weight of standard needle | 2.5 ± 0.05 g |
Power consumption | 200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimensions (W × L × H) | 650 × 500 × 850 mm |
Weight | 30 kg |
Penetrometer |
|
||||||||||||||||||
Circulatory Water Bath |
|
Measurement range | 0 to 600 penetration scale |
Timing range | 0 sec to 60 sec |
Time accuracy error | ≥ ± 0.1 seconds |
Resolution | 0.1 penetration |
Power consumption | 200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Needle diameter | 50 mm |
Sample container (D × H) | 55 mm × 35 mm |
Dimensions (L × W × H) | 260 × 400 × 600 mm |
Standard weight | 50 g |
Weight of standard needle | 2.5 ± 0.05 g |
Net Weight | 15 kg |